Nonlinear generalization of Den Hartog׳s equal-peak method
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This study addresses the mitigation of a nonlinear resonance of a mechanical system. In view of the narrow bandwidth of the classical linear tuned vibration absorber, a nonlinear absorber, termed the nonlinear tuned vibration absorber (NLTVA), is introduced in this paper. An unconventional aspect of the NLTVA is that the mathematical form of its restoring force is tailored according to the nonlinear restoring force of the primary system. The NLTVA parameters are then determined using a nonlinear generalization of Den Hartog׳s equal-peak method. The mitigation of the resonant vibrations of a Duffing oscillator is considered to illustrate the proposed developments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Theory of the Dynamic Vibration Absorber
Ormondroyd, J., & Den Hartog, J. P. (1928) · Transactions of the American Society of Mechanical Engineers · doi:10.1115/1.4058553 · Cited by 779
Nonlinear Targeted Energy Transfer in Mechanical and Structural Systems
(2009) · Solid Mechanics and Its Applications · doi:10.1007/978-1-4020-9130-8 · Cited by 699 · cited 2×
“Nonlinear vibration absorbers, including the autoparametric vibration absorber [2, 3], the nonlinear energy sink (NES) [4, 5, 6, 7, 8] and other variants [9, 10, 11, 12, 13, 14], can absorb disturbances in wide ranges of frequencies due to their increased bandwidth.”
BackgroundSelf-citationEnergy Pumping in Nonlinear Mechanical Oscillators: Part II—Resonance Capture
Vakakis, A. F., & Gendelman, O. (2001) · Journal of Applied Mechanics · doi:10.1115/1.1345525 · Cited by 697
A Note on the Damped Vibration Absorber
Brock, J. E. (1946) · Journal of Applied Mechanics · doi:10.1115/1.4009588 · Cited by 356
Cited by
Numerical and experimental investigations of a rotating nonlinear energy sink
AL-Shudeifat, M. A., Wierschem, N. E., Bergman, L. A., & Vakakis, A. F. (2017) · Meccanica · doi:10.1007/s11012-016-0422-2 · Cited by 109
Design of a magnetic vibration absorber with tunable stiffnesses
Benacchio, S., Malher, A., Boisson, J., & Touzé, C. (2016) · Nonlinear Dynamics · doi:10.1007/s11071-016-2731-3 · Cited by 95
“method has been proposed in [17], leading to the definition of a nonlinear tuned vibration absorber (NLTVA), which can be used e.”
BackgroundMethodWang, J., Wierschem, N. E., Wang, B., & Spencer, B. F. (2020) · The Structural Design of Tall and Special Buildings · doi:10.1002/tal.1692 · Cited by 62
Metadata
- Authors
- Habib, G., Detroux, T., Viguié, R., & Kerschen, G.
- Venue
- Mechanical Systems and Signal Processing
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 52-53
- Pages
- 17-28
- ISSN
- 0888-3270 (ISSN-L)
- OpenAlex
- W2055580247
- Cited by
- 170
- References
- 4
- FWCI
- 22.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.