The Theory of the Dynamic Vibration Absorber
Abstract
The “vibration absorber” discussed in this paper consists of a small vibratory system tuned to the operating frequency of a larger machine and attached to it in a suitable location. When properly designed this will reduce the vibrations of the machine itself materially. The absorber, without damping, annihilates vibrations of its own frequency completely, but creates two other critical speeds in the machine system. Therefore it is suitable only for applications on constant-speed machinery. When damping is introduced into the absorber it constitutes a simple and efficient means of diminishing the vibrations of a machine of variable speed. An analysis of its operation in simple cases with and without damping is given in the paper, tests made on a model are described, and actual applications are discussed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cited by
Sorted by citations
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828 · see citing works
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782 · see citing works
Parametric study and simplified design of tuned mass dampers
Rana, R., & Soong, T. T. (1998) · Engineering Structures · doi:10.1016/s0141-0296(97)00078-3 · Cited by 651 · see citing works
Research developments in vibration control of structures using passive tuned mass dampers
Elias, S., & Matsagar, V. (2017) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2017.09.015 · Cited by 545 · see citing works
Performance evaluation for inerter-based dynamic vibration absorbers
Hu, Y., & Chen, M. Z. Q. (2015) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2015.06.003 · Cited by 325 · see citing works
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256 · see citing works
Dynamic response and optimal design of structures with large mass ratio TMD
De Angelis, M., Perno, S., & Reggio, A. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1117 · Cited by 239 · see citing works
Frequency analysis of the tuned mass damper
Krenk, S. (2005) · Journal of Applied Mechanics · doi:10.1115/1.2062867 · Cited by 217 · see citing works
Tuned mass-damper-inerter (TMDI) for suppressing edgewise vibrations of wind turbine blades
Zhang, Z., & Fitzgerald, B. (2020) · Engineering Structures · doi:10.1016/j.engstruct.2020.110928 · Cited by 132 · see citing works
The periodically extended stiffness nonlinear energy sink
Dekemele, K., Habib, G., & Loccufier, M. (2022) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2021.108706 · Cited by 63 · see citing works
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
Konar, T., & Ghosh, A. (. (2024) · Structures · doi:10.1016/j.istruc.2024.106459 · Cited by 57 · see citing works
- Authors
- Ormondroyd, J., & Den Hartog, J. P.
- Affiliations
- Westinghouse Electric (United States) (US)
- Power Engineering Department, Westinghouse Electric & Manufacturing Company
- Venue
- Transactions of the American Society of Mechanical Engineers
- Publisher
- ASME International
- Published
- 1928-01-01
- Volume
- 49-50
- Issue
- 2
- ISSN
- 0097-6822 (ISSN-L)
- OpenAlex
- W611191726
- Cited by
- 779
- References
- 0
- Citations by year
- 2026: 26 · 2025: 48 · 2024: 81 · 2023: 60 · 2022: 45 · 2021: 52 · 2020: 45 · 2019: 41 · 2018: 30 · 2017: 30 · 2016: 31 · 2015: 23 · 2014: 34 · 2013: 29 · 2012: 17
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Transactions of the American Society of Mechanical Engineers (publishedVersion)
- Topics
- Physical Sciences › Engineering › Civil and Structural Engineering › Vibration Control and Rheological Fluids
- Physical Sciences › Engineering › Control and Systems Engineering › Vibration and Dynamic Analysis
- Physical Sciences › Engineering › Mechanical Engineering › Mechanical Engineering Research and Applications
- Keywords
- dynamic vibration absorber, vibration damping, tuned mass damper, critical speed, absorber design, model testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review