Cited by 25Structural Health Monitoring TechniquesMachine Fault Diagnosis TechniquesFault Detection and Control Systems

Neutralization of temperature effects in damage diagnosis of MDOF systems by combinations of autoencoders and particle filters

Open access
Cadini, Francesco, Lomazzi, Luca, Ferrater Roca, Marc, Sbarufatti, Claudio, Giglio, Marco·2022·Mechanical Systems and Signal Processing

Integrity signals

Registry

Crossref · 10.1016/j.ymssp.2021.108048

Cites

60 of 60 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Cadini, F., Lomazzi, L., Ferrater Roca, M., Sbarufatti, C., & Giglio, M.
Affiliations
Politecnico di Milano (IT)
Corresponding author
Cadini, Francesco
Venue
Mechanical Systems and Signal Processing
Publisher
Elsevier BV
Published
2022-01
Volume
162
Pages
108048
ISSN
0888-3270 (ISSN-L)
OpenAlex
W3173511902
Cited by
25
References
60
Citations by year
2026: 1 · 2025: 5 · 2024: 5 · 2023: 6 · 2022: 7 · 2021: 1
FWCI
2.46
Type
journal article
Language
en
Open access
Locations
  • Mechanical Systems and Signal Processing (publishedVersion)
  • Virtual Community of Pathological Anatomy (University of Castilla La Mancha) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Civil and Structural Engineering › Structural Health Monitoring Techniques
  • Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
  • Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
Keywords
structural health monitoring, structural damage detection, damage localization, particle filter, autoencoder, multi-degree-of-freedom systems, temperature effects, fault indicators, vibration measurement, automatic thresholding

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review