Doppler-echocardiographic assessment of pulmonary regurgitation in adults with repaired tetralogy of Fallot: comparison with cardiovascular magnetic resonance imaging
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Gatzoulis, M. A., Balaji, S., Webber, S. A., Siu, S. C., Hokanson, J. S., Poile, C., Rosenthal, M., Nakazawa, M., Moller, J. H., Gillette, P. C., et al. (2000) · The Lancet · doi:10.1016/s0140-6736(00)02714-8 · Cited by 1,779
Self-citationNollert, G., Fischlein, T., Bouterwek, S., Böhmer, C., Klinner, W., & Reichart, B. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00318-5 · Cited by 761
Lorenz, C., Walker, E., Morgan, V., Klein, S., & Graham, T. (1999) · Journal of Cardiovascular Magnetic Resonance · doi:10.3109/10976649909080829 · Cited by 717
Left Atrial Volume: A Powerful Predictor of Survival After Acute Myocardial Infarction
Møller, J. E., Hillis, G. S., Oh, J. K., Seward, J. B., Reeder, G. S., Wright, R. S., Park, S. W., Bailey, K. R., & Pellikka, P. A. (2003) · Circulation · doi:10.1161/01.cir.0000066318.21784.43 · Cited by 690
Tsang, T. S. M., Barnes, M. E., Bailey, K. R., Leibson, C. L., Montgomery, S. C., Takemoto, Y., Diamond, P. M., Marra, M. A., Gersh, B. J., Wiebers, D. O., et al. (2001) · Mayo Clinic Proceedings · doi:10.4065/76.5.467 · Cited by 631
Davlouros, P. A., Kilner, P. J., Hornung, T. S., Li, W., Francis, J. M., Moon, J. C. C., Smith, G. C., Tat, T., Pennell, D. J., & Gatzoulis, M. A. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02566-4 · Cited by 553
Self-citationTherrien, J., Siu, S. C., McLaughlin, P. R., Liu, P. P., Williams, W. G., & Webb, G. D. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00930-x · Cited by 543
Therrien, J., Siu, S. C., Harris, L., Dore, A., Niwa, K., Janousek, J., Williams, W. G., Webb, G., & Gatzoulis, M. A. (2001) · Circulation · doi:10.1161/01.cir.103.20.2489 · Cited by 467
Self-citationGatzoulis, M. A., Clark, A. L., Cullen, S., Newman, C. G. H., & Redington, A. N. (1995) · Circulation · doi:10.1161/01.cir.91.6.1775 · Cited by 410
Self-citation
Cited by
Recommendations for Noninvasive Evaluation of Native Valvular Regurgitation
Zoghbi, W. A., Adams, D., Bonow, R. O., Enriquez-Sarano, M., Foster, E., Grayburn, P. A., Hahn, R. T., Han, Y., Hung, J., Lang, R. M., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2017.01.007 · Cited by 3,556
Lancellotti, P., Pibarot, P., Chambers, J., La Canna, G., Pepi, M., Dulgheru, R., Dweck, M., Delgado, V., Garbi, M., Vannan, M. A., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab253 · Cited by 474
Zoghbi, W. A., Asch, F. M., Bruce, C., Gillam, L. D., Grayburn, P. A., Hahn, R. T., Inglessis, I., Islam, A. M., Lerakis, S., Little, S. H., et al. (2019) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.01.003 · Cited by 439
Pulmonary regurgitation: not a benign lesion
Bouzas, B., Kilner, P. J., & Gatzoulis, M. A. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi091 · Cited by 336
Self-citationApplications of phase-contrast flow and velocity imaging in cardiovascular MRI
Gatehouse, P. D., Keegan, J., Crowe, L. A., Masood, S., Mohiaddin, R. H., Kreitner, K.-F., & Firmin, D. N. (2005) · European Radiology · doi:10.1007/s00330-005-2829-3 · Cited by 331
Valente, A. M., Cook, S., Festa, P., Ko, H. H., Krishnamurthy, R., Taylor, A. M., Warnes, C. A., Kreutzer, J., & Geva, T. (2014) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.11.009 · Cited by 317
Indications and Timing of Pulmonary Valve Replacement After Tetralogy of Fallot Repair
Geva, T. (2006) · Seminars in Thoracic and Cardiovascular Surgery: Pediatric Cardiac Surgery Annual · doi:10.1053/j.pcsu.2006.02.009 · Cited by 275
Cardiovascular magnetic resonance phase contrast imaging
Nayak, K. S., Nielsen, J.-F., Bernstein, M. A., Markl, M., D. Gatehouse, P., M. Botnar, R., Saloner, D., Lorenz, C., Wen, H., S. Hu, B., et al. (2015) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-015-0172-7 · Cited by 264
Cardiovascular Magnetic Resonance Imaging for Valvular Heart Disease: Technique and Validation
Cawley, P. J., Maki, J. H., & Otto, C. M. (2009) · Circulation · doi:10.1161/circulationaha.107.742486 · Cited by 260
World Interactive Network Focused On Critical UltraSound ECHO-ICU Group, Price, S., Via, G., Sloth, E., Guarracino, F., Breitkreutz, R., Catena, E., & Talmor, D. (2008) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-6-49 · Cited by 255
The right ventricle in congenital heart disease
Davlouros, P. A., Niwa, K., Webb, G., & Gatzoulis, M. A. (2006) · Heart · doi:10.1136/hrt.2005.077438 · Cited by 250
Self-citationMercer-Rosa, L., Yang, W., Kutty, S., Rychik, J., Fogel, M., & Goldmuntz, E. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.112.972588 · Cited by 171
“Likewise, attempts at classifying the severity of PR by echocardiogram have been made.(24,25) However, the inability of other studies to replicate those measures raises questions about their validity.”
BackgroundMethodHeart valve disease: investigation by cardiovascular magnetic resonance
Myerson, S. G. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-7 · Cited by 171
“This method compares well to quantification by comparing ventricular stroke volumes [59], correlates with echocardiographic parameters [62], and a regurgitant fraction ≥40% has been considered severe Figure 11 Assessing mitral stenosis by direct planimetry of the mitral tips.”
MethodAvesani, M., Borrelli, N., Krupickova, S., Sabatino, J., Donne, G. D., Ibrahim, A., Piccinelli, E., Josen, M., Michielon, G., Fraisse, A., et al. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.07.026 · Cited by 26
Costantini, P., Perone, F., Siani, A., Groenhoff, L., Muscogiuri, G., Sironi, S., Marra, P., Carriero, S., Pavon, A. G., & Guglielmo, M. (2022) · Journal of Imaging · doi:10.3390/jimaging8100278 · Cited by 25
“This index is determined by the ratio of the PR duration to the total diastolic time [21].”
Background
Metadata
- Authors
- Li, W., Davlouros, P. A., Kilner, P. J., Pennell, D. J., Gibson, D., Henein, M. Y., & Gatzoulis, M. A.
- Venue
- American Heart Journal
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 147
- Issue
- 1
- Pages
- 165-172
- ISSN
- 0002-8703 (ISSN-L)
- OpenAlex
- W2160584207
- Cited by
- 191
- References
- 31
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.