Transtelephonic electrocardiographic transmission for management of cardiac arrhythmias
Abstract
Brief periods of transtelephonic electrocardiographic transmission conducted at periodic intervals or during sporadic symptoms may provide an inexpensive and reliable alternative to extended ambulatory electrocardiographic tape recordings. Sixty-one patients were enrolled in a transtelephonic electrocardiographic transmissions program. In 51 patients with documented arrhythmias (group I), telephone electrocardiographic transmissions were used to monitor antiarrhythmic drug therapy. In 10 patients, telephone electrocardiographic transmission was used in an attempt to diagnose infrequent symptoms suggestive of arrhythmia (group II). Of the 650 telephone electrocardiographic transmissions received, 73 (11%) revealed a clinically significant event, whereas 577 (89%) did not show any significant disturbances of cardiac rhythm. Of the 61 patients entered into the program, 29 (48%) had a clinically significant event identified during 1 or more transmissions. In group I, transtelephonic electrocardiographic transmission prompted a change in therapy in 37% of the patients. Of the 10 patients in group II, clinically significant events were noted during telephone electrocardiographic transmissions in each patient. Assuming a yield of 1 clinically significant event detected per 10 telephone electrocardiographic transmissions and a similar yield on long-term ambulatory electrocardiographic recordings, use of telephone electrocardiographic transmissions offers a cost-effective means of following patients with significant cardiac arrhythmias who are receiving potent antiarrhythmic drugs. In addition, telephone electrocardiographic transmission is a suitable diagnostic technique for patients with infrequent symptoms suggestive of cardiac arrhythmias.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
External and implantable loop recorders, mobile cardiac outpatient telemetry, and pacemakers and ICDs provide a significantly higher yield than standard patient-activated loop recorders in patients with infrequent palpitations.
“and provide a significantly higher yield than standard patient-activated loop recorders in patients with infrequent palpitations.49,73 -79”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [79]
External and implantable loop recorders, mobile cardiac outpatient telemetry, and pacemakers and ICDs can detect asymptomatic clinically significant arrhythmias automatically, without patient activation.
“The external and implantable loop recorders, mobile cardiac outpatient telemetry, and pacemakers and ICDs can detect asymptomatic clinically significant arrhythmias automatically (i.e. with no activation by the patient)”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [79]
The citation lists haven’t been fetched yet
References 10 · Cited by 37
- Authors
- Antman, E. M., Ludmer, P. L., McGowan, N., Bosak, M., Friedman, P. L., Alvarez, P., Then, V., & Nevins, D.
- Affiliations
- Brigham and Women's Hospital (US)
- Corresponding author
- Antman, Elliott M.
- ORCID
- Antman, Elliott M.
- Venue
- The American Journal of Cardiology
- Publisher
- Elsevier BV
- Published
- 1986-11
- Volume
- 58
- Issue
- 10
- Pages
- 1021-1024
- ISSN
- 0002-9149 (ISSN-L)
- OpenAlex
- W1984470372
- Cited by
- 37
- References
- 10
- Citations by year
- 2020: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2012: 1
- FWCI
- 1.46
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The American Journal of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- cardiac arrhythmias, Holter monitoring, cost-effectiveness, arrhythmia diagnosis, remote patient monitoring
- MeSH terms
- Adult, Aged, Anti-Arrhythmia Agents, Arrhythmias, Cardiac, Electrocardiography, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Telephone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review