The DOI matches its Crossref record.
Contrast radiology, computed tomography and ultrasonography in detecting internal fistulas and intra-abdominal abscesses in Crohn's disease: a prospective comparative study
Abstract
OBJECTIVE: Accurate assessment of intestinal complications of Crohn's disease (CD) is extremely important, both in clinical practice and in trials. The accuracy of radiographic and ultrasonographic diagnosis of internal fistulae and abscesses complicating CD is still debated and requires further investigation. We compared ultrasonography (US) and contrast radiography in detecting intestinal fistulae and abscesses complicating CD. METHODS: A prospective study was carried out on 625 consecutive CD patients who underwent complete evaluation of the intestinal tract by means of colonoscopy and double contrast barium enema, small bowel enteroclysis, and abdominal ultrasound (US). Computed tomography (CT) was also carried out in cases of severe CD with clinical suspicion of septic complications. The accuracy of US, barium radiology, and CT in detecting internal fistulae and abscesses was assessed by comparing results with intraoperative findings in 128 consecutive patients who underwent operation immediately after diagnostic workup. RESULTS: Internal fistulae and intra-abdominal abscesses were identified intraoperatively in 56 (43.7%) and 26 (20.3%) patients, respectively. Diagnostic accuracy of US and x-ray studies in detecting internal fistulae was comparable (85.2% vs 84.8%), with sensitivity of 71.4% for US and 69.6% for x-ray studies, and specificity of 95.8% for both. Combination of radiographic techniques and US significantly improved diagnostic accuracy in detection of internal fistulae. In severe cases of CD with clinical suspicion of septic complications such as abdominal mass or fever, the accuracy of US, barium studies, and CT was 88.5%, 80.3%, and 77%, respectively (p = ns). The presence of abscesses was correctly detected in 90.9% of cases by means of US and in 86.4% by CT (p = ns), although accuracy was higher for CT (91.8%) than for US (86.9%) because of false positive results in US studies. CONCLUSIONS: Despite the fact that barium radiology is widely considered the method of choice in detection of internal fistulae, accuracy is not entirely satisfactory. Comparable accuracy was found for US and CT. The combination of barium and US studies, or the sole use of US in more CD patients with more severe disease, can reliably detect most internal fistulae and abscesses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Maaser, C., Sturm, A., Vavricka, S. R., Kucharzik, T., Fiorino, G., Annese, V., Calabrese, E., Baumgart, D. C., Bettenworth, D., Borralho Nunes, P., et al. (2019) · Journal of Crohn's and Colitis · doi:10.1093/ecco-jcc/jjy113 · Cited by 1,823
Van Assche, G., Dignass, A., Panes, J., Beaugerie, L., Karagiannis, J., Allez, M., Ochsenkühn, T., Orchard, T., Rogler, G., Louis, E., et al. (2010) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2009.12.003 · Cited by 1,453
Panes, J., Bouhnik, Y., Reinisch, W., Stoker, J., Taylor, S. A., Baumgart, D. C., Danese, S., Halligan, S., Marincek, B., Matos, C., et al. (2013) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2013.02.020 · Cited by 668
Self-citationPanés, J., Bouzas, R., Chaparro, M., García-Sánchez, V., Gisbert, J. P., Martínez de Guereñu, B., Mendoza, J. L., Paredes, J. M., Quiroga, S., Ripollés, T., et al. (2011) · Alimentary Pharmacology & Therapeutics · doi:10.1111/j.1365-2036.2011.04710.x · Cited by 659
A comprehensive review and update on Crohn's disease
Gajendran, M., Loganathan, P., Catinella, A. P., & Hashash, J. G. (2018) · Disease-a-Month · doi:10.1016/j.disamonth.2017.07.001 · Cited by 550
Metadata
- Authors
- Maconi, G.
- Venue
- The American Journal of Gastroenterology
- Published
- 2003-07
- Volume
- 98
- Issue
- 7
- Pages
- 1545-1555
- ISSN
- 0002-9270 (ISSN-L)
- OpenAlex
- W2106661655
- Cited by
- 206
- References
- 0
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Contrast radiology, computed tomography and ultrasonography in detecting internal fistulas and intra-abdominal abscesses in Crohn's disease: a prospective comparative study. https://app.cochat.ai/papers/10.1016/s0002-9270(03)00303-4
- The paper
- Maconi, G. (2003). Contrast radiology, computed tomography and ultrasonography in detecting internal fistulas and intra-abdominal abscesses in Crohn's disease: a prospective comparative study. The American Journal of Gastroenterology. https://doi.org/10.1016/s0002-9270(03)00303-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.