A close look at early embryonic development with the high-frequency transvaginal transducer
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Transabdominal sonography has been, for the past two decades, used as an effective diagnostic and research tool in obstetrics. It is predominantly used in the second and third trimesters of gestation. Its use in the first trimester is relatively limited and mostly diagnostic in nature. The introduction of the higher frequency transvaginal transducer probe, with its higher resolution of the images, opens new possibilities to study early gestation. We studied embryonic development in 38 well-dated and normal pregnancies. A well-defined intrauterine gestational sac could be seen at 4 weeks and 1 to 4 days of menstrual age. The beta-subunit of human chorionic gonadotropin level at this time was 450 to 750 mlU/ml. Structures such as the yolk sac, membranes, ventricular system in the brain, musculoskeletal system, and cord were described and illustrated. Textbooks and atlases were used for comparative purposes. High-resolution transvaginal sonography will facilitate first-trimester perinatology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moore, K. L., & Persaud, T. V. N. (1988) · Cited by 875
The technique of transvaginal sonography with the use of a 6.5 MHz probe
Timor‐Tritsch, I. E., Bar-Yam, Y., Elgali, S., & Rottem, S. (1988) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(88)90210-4 · Cited by 87
Self-citationWladimiroff, J. W. (1988) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(88)90030-0 · Cited by 65
Cited by
RETIRED: Determination of Gestational Age by Ultrasound
Butt, K., Lim, K., Lim, K., Bly, S., Butt, K., Cargill, Y., Davies, G., Denis, N., Hazlitt, G., Morin, L., et al. (2014) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(15)30664-2 · Cited by 240
Ectopic Pregnancy: Prospective Study With Improved Diagnostic Accuracy☆☆☆★★★
Kaplan, B. C., Dart, R. G., Moskos, M., Kuligowska, E., Chun, B., Hamid, M. A., Northern, K., Schmidt, J., & Kharwadkar, A. (1996) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(96)70131-2 · Cited by 186
Assessment of fetal anatomy at the 11–14‐week ultrasound examination
Souka, A. P., Pilalis, A., Kavalakis, Y., Kosmas, Y., Antsaklis, P., & Antsaklis, A. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1775 · Cited by 173
Prenatal ultrasound and fetal MRI: The comparative value of each modality in prenatal diagnosis
Pugash, D., Brugger, P. C., Bettelheim, D., & Prayer, D. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.06.031 · Cited by 173
Detection of fetal structural abnormalities at the 11–14 week ultrasound scan
Carvalho, M. H. B., Brizot, M. L., Lopes, L. M., Chiba, C. H., Miyadahira, S., & Zugaib, M. (2002) · Prenatal Diagnosis · doi:10.1002/pd.200 · Cited by 165
Metadata
- Authors
- Timor-Tritsch, I. E., Farine, D., & Rosen, M. G.
- Venue
- American Journal of Obstetrics and Gynecology
- Publisher
- Elsevier BV
- Published
- 1988-09
- Volume
- 159
- Issue
- 3
- Pages
- 676-681
- ISSN
- 0002-9378 (ISSN-L)
- OpenAlex
- W2030026075
- Cited by
- 188
- References
- 3
- FWCI
- 16.84
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A close look at early embryonic development with the high-frequency transvaginal transducer. https://app.cochat.ai/papers/10.1016/s0002-9378(88)80033-4
- The paper
- Timor-Tritsch, I. E., Farine, D., & Rosen, M. G. (1988). A close look at early embryonic development with the high-frequency transvaginal transducer. American Journal of Obstetrics and Gynecology. https://doi.org/10.1016/s0002-9378(88)80033-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.