Cited by 275Stroke Rehabilitation and RecoverySpinal Cord Injury ResearchProsthetics and Rehabilitation Robotics

Clinical use of the odstock dropped foot stimulator: Its effect on the speed and effort of walking

Taylor, Paul N., Burridge, Jane H., Dunkerley, Anna L., Wood, Duncan E., Norton, Jonathan A., Singleton, Christine, Swain, Ian D.·1999·Archives of Physical Medicine and Rehabilitation

Abstract

Objective To assess the clinical effectiveness of the Odstock dropped foot stimulator by analysis of its effect on physiological cost index (PCI) and speed of walking. This functional electrical stimulation (FES) device stimulates the common peroneal nerve during the swing phase of gait. Design A retrospective study of patients who had used the device for 4 1/2 months. Subjects One hundred fifty-one patients with a dropped foot resulting from an upper motor neuron lesion. Setting A medical physics and biomedical engineering department of a district general hospital specializing in the clinical application of FES and a neurophysiotherapy department at a separate hospital. Main outcome measures Changes in walking speed and effort of walking, as measured by PCI over a 10-meter course. Results There was a 92.7% compliance with treatment. Stroke patients showed a mean increase in walking speed of 27% (p Conclusions The measured differences in walking with and without stimulation were statistically significant in the stroke and multiple sclerosis groups. In this study use of the stimulator improved walking. Those with stroke demonstrated a short-term "carry-over" effect.

Integrity signals

Registry

Crossref · 10.1016/s0003-9993(99)90333-7

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

The citation lists haven’t been fetched yet

References 13 · Cited by 275

Authors
Taylor, P. N., Burridge, J. H., Dunkerley, A. L., Wood, D. E., Norton, J. A., Singleton, C., & Swain, I. D.
Affiliations
  • Salisbury District Hospital (GB)
  • University College London (GB)
  • Birmingham City Hospital (GB)
Venue
Archives of Physical Medicine and Rehabilitation
Publisher
Elsevier BV
Published
1999-12
Volume
80
Issue
12
Pages
1577-1583
ISSN
0003-9993 (ISSN-L)
OpenAlex
W2038344442
Cited by
275
References
13
Citations by year
2026: 2 · 2025: 4 · 2024: 4 · 2023: 7 · 2022: 2 · 2021: 8 · 2020: 9 · 2019: 6 · 2018: 11 · 2017: 10 · 2016: 10 · 2015: 18 · 2014: 22 · 2013: 19 · 2012: 16
FWCI
5.23
Type
journal article
Language
en
Open access
closed
Locations
  • Archives of Physical Medicine and Rehabilitation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Health Sciences › Medicine › Pathology and Forensic Medicine › Spinal Cord Injury Research
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
functional electrical stimulation, common peroneal nerve stimulation, walking speed, walking effort, physiological cost index, stroke, multiple sclerosis, upper motor neuron lesion, residual effects, medication adherence
MeSH terms
Adult, Aged, Electric Stimulation Therapy, Physical Exertion, Gait, Humans, Middle Aged, Multiple Sclerosis, Retrospective Studies, Spinal Cord Injuries, Range of Motion, Articular, Walking, Treatment Outcome, Peroneal Neuropathies, Stroke

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review