The DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Highly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Open accessAbstract
Two-photon fluorescence excitation is being increasingly used in laser scan microscopy due to very low photodamage induced by this technique under normal operation. However, excitation intensity has to be kept low, because nonlinear photodamage sets in when laser power is increased above a certain threshold. We studied this kind of damage in bovine adrenal chromaffin cells, using two different indicators of damage: changes in resting [Ca(2+)] level and the degranulation reaction. In agreement with previous studies, we found that, for both criteria, damage is proportional to the integral (over space and time) of light intensity raised to a power approximately 2.5. Thus, widening the laser pulse shape at constant average intensity both in time and in focal volume is beneficial for avoiding this kind of damage. Both measures, of course, reduce the two-photon fluorescence excitation. However, loss of signal can be compensated by increasing excitation power, such that, at constant damaging potential, signals may be even larger with long pulses and large focal volumes, because the exponent of the power law of damage is higher (mu approximately 2.5) than that of the two-photon signal (mu approximately 2).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This uncaging regime produced little or no photodamage29, as shown by the stability of the amplitudes of the 2pEPSCs over 1 min (Fig. 1h).”
From Dendritic spine geometry is critical for AMPA receptor expression in hippocampal CA1 pyramidal neurons (2001) · cites this paper as [29]
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Handbook of fluorescent probes and research chemicals
Haugland, R. P. (1996) · Medical Entomology and Zoology · Cited by 2,793
Xu, C., & Webb, W. W. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000481 · Cited by 2,198
Ultrashort Laser Pulse Phenomena
Diels, J., & Rudolph, W. (2006) · Elsevier eBooks · doi:10.1016/b978-0-12-215493-5.x5000-9 · Cited by 853
Theory and Practice of Scanning Optical Microscopy
Dainty, J. C. (1985) · Optica Acta International Journal of Optics · doi:10.1080/713821694 · Cited by 773
Lynch, D. K. (1987) · Journal of the Optical Society of America A · doi:10.1364/josaa.4.000558 · Cited by 756
Photon Upmanship: Why Multiphoton Imaging Is More than a Gimmick
Denk, W. T., & Svoboda, K. (1997) · Neuron · doi:10.1016/s0896-6273(00)81237-4 · Cited by 679
Breakdown threshold and plasma formation in femtosecond laser–solid interaction
von der Linde, D., & Schüler, H. (1996) · Journal of the Optical Society of America B · doi:10.1364/josab.13.000216 · Cited by 308
Ca2+ Fluorescence Imaging with Pico- and Femtosecond Two-Photon Excitation: Signal and Photodamage
Koester, H. J., Baur, D., Uhl, R., & Hell, S. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77063-3 · Cited by 265
König, K., Becker, T., Fischer, P., Riemann, I., & Halbhuber, K. J. (1999) · Optics Letters · doi:10.1364/ol.24.000113 · Cited by 259
Research works printed but not linked: 2
- Clayton, 1977, Vol. 1 and 2
- Ridsdale, 1993, The viability of cultured cells under two-photon laser scanning microscopy (abstr.), Biophys. J., 64, A109
Cited by
Sorted by citations
Items 401–441 of 441
The development of a high speed 3D 2-photon microscope for neuroscience
Kirkby, P. A. (2010) · UCL Discovery (University College London)
Application of two-photon flash photolysis to measure microscopic diffusion and calcium fluxes
Cannell, M. B., Jacobs, M. D., Donaldson, P. J., & Soeller, C. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.601431
New methods in femtosecond multiphoton microscopy
Silberberg, Y. R., Yelin, D., Oron, D., Dudovich, N., & Thiberge, S. Y. (2003) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.478019
Cellular vitality of PC12 cells revealed through auto-fluorescence induced by two-photon excitation
Perevedentseva, E. V., Karmenyan, A., & Kao, F. (2005) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.640220
der Doktorw, E. (2005)
IMAGING INTERFEROMETRIC MICROSCOPY TO THE LIMITS OF AVAILABLE FREQUENCY SPACE
Neumann, A. (2014) · UNM’s Digital Repository (University of New Mexico)
Two-Photon Fluorescence Microendoscopy In Vivo Mammalian Brain Imaging Using One- and
Jung, J. C., Mehta, A., Aksay, E. R. F., Stepnoski, R. A., & Märk, J. (2015)
Wang, H., Langohr, I. M., Sturek, M. S., & Cheng, J. (2009)
Optical fiber based ultrashort pulse multispectral nonlinear optical microscopy
Larson, A. M. (2009) · OakTrust (Texas A&M University Libraries)
Dual-comb spectroscopy of fundamental vibrational transitions
Holzner, S. (2015) · Elektronische Hochschulschriften der LMU München (Ludwig-Maximilians-Universität München) · doi:10.5282/edoc.18996
Improving 2-Photon Microscopy by Beam Multiplexing and extended Excitation Bandwidth
Pingel, T., Andresen, V., & Spiecker, H. (2010) · Frontiers in Optics · doi:10.1364/fio.2010.fml1
Nanoscale fluid motion via molecular pores and polymer actuators
Cannell, M. B., Kilmartin, P. A., Jacobs, M. D., Valiavalappil, S., Travaš‐Sejdić, J., & Soeller, C. (2007) · Handai Nanophotonics · doi:10.1016/s1574-0641(07)80019-2
Multimodal label-free low fluence nonlinear imaging of living systems with high-throughput
Macias-Romero, C., Zubkovs, V., Wang, S., & Roke, S. (2017) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2017.jth3a.1
Nanoparticle-Assisted Stimulated Emission Depletion (STED) Super-Resolution Nanoscopy
Sivan, Y., & Sonnefraud, Y. (2017) · doi:10.1201/9781315206530-8
Which Imaging Modality To Use?—What Do You Really Need To Detect?
Cole, R. W. (2014)
Lin, T.-E. L., Lin, Y.-J., Sun, C., Pick, H. M., Chen, J., Lesch, A. S., & Girault, H. H. (2017) · Angewandte Chemie · doi:10.1002/ange.201709271
Adaptive multiphoton imaging by high peak-power coherent fiber supercontinuum
Tu, H., & Boppart, S. A. (2017) · International Conference on Photonics and Imaging in Biology and Medicine (PIBM) · doi:10.1364/pibm.2017.w3a.87
Vogel, A. (2006) · Defense Technical Information Center (DTIC)
Compact fiber lasers for stimulated Raman scattering microscopy
Kieu, K. Q. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85158-9.00019-1
Confocal Laser Scanning Polarimetry
Gonzalez, M., Le, V. N. D., & Ramella‐Roman, J. C. (2022) · Springer eBooks · doi:10.1007/978-3-031-04741-1_12
Meier, K. A., Ryan, D. P., Thompson, D. C., Newell, R., Sandoval, R. H., & Werner, J. H. (2023) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_si.2023.sm1i.3
Bosman, G. W., Badrodien, I., & Neethling, P. (2024) · Research Square · doi:10.21203/rs.3.rs-4001732/v1
Simultaneous 2- and 3-photon multiplane imaging across cortical layers in freely moving micePreprint
Klioutchnikov, A., Wallace, D. J., Berdahl, C., Sugi, A., Sawinski, J., & Kerr, J. N. D. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.08.01.668113
Evaluation of a nanosecond dissipative soliton resonance fiber laser for multiphoton microscopy
Kunio, K., Bojęś, P., Soboń, G., Krzempek, K., & Bogusławski, J. (2025) · Scientific Reports · doi:10.1038/s41598-025-28372-0
In vivo cellular-resolution imaging of retina: modality, cells, and clinical implications
Pi, S., Brown, R. B., Yun, S., & Wang, L. (2026) · Frontiers in Ophthalmology · doi:10.3389/fopht.2025.1682303
Time-reversal-based loss-tolerant absorption parameter measurement
Zhang, X., Yao, W., Shi, S., Tian, L., & Zheng, Y. (2026) · Laser and Particle Beams · doi:10.3788/lpb.2026.10004
Diffractive scanning live volumetric two-photon microscopy within the contracting mouse intestinePreprint
Jurkevicius, J., Alata, M., Wiggert, M., Rixius, M., Reinhards, S., Thielking, M., Stock, C., Fung, C., Favre, A., Theisen‐Kunde, D., et al. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.03.18.712419
Large volume multicolor nonlinear microscopy of neural tissues
Abdeladim, L. (2018) · theses.fr (ABES) · doi:10.70675/ae22132bze166z4af6zae71z08b776007ea9
Development of advanced optical systems for spatially and temporally precise brain interrogation
Molinier, C. (2021) · theses.fr (ABES) · doi:10.70675/128c1cd5z1210z4f3ez858dzd0acd752045b
Advanced optical methods for precise high-throughput in vivo connectivity mapping
Chan, C. Y. (2024) · theses.fr (ABES) · doi:10.70675/98023e25z7828z47fdzab42z41bfd46492af
All-optical interrogation of the role of interneurons in CA1 cell assemblies
Vorobyev, A. (2023) · theses.fr (ABES) · doi:10.70675/eb10a4e1za595z4f16z9e3bz115344f3d87a
Nonlinear optical microscopy of nervous tissue : lipid and metabolism imaging
Asadipour, B. (2023) · theses.fr (ABES) · doi:10.70675/a6df7cc5z7b3cz4971zb3edzfa969cc63866
Zhu, L., Gottlieb, D., Maioli, V., Hubert, A., Druon, F., Mahou, P., Beaurepaire, E., & Supatto, W. (2026) · Optica · doi:10.1364/optica.588084
(2026) · De Gruyter eBooks · doi:10.1515/9783110427035-017
Zhou, J., Wang, Y., Ning, Y., Zhao, W., Fan, D., Hou, D., Fei, Y., Ma, J., Zhao, J., & Mi, L. (2026) · Environmental Science Nano · doi:10.1039/d6en00334f
Depth-adapted adaptive optics for three-photon microscopy
Hu, Q., Wang, J., Atilgan, H., Lak, A., & Booth, M. J. (2026) · Biomedical Optics Express · doi:10.1364/boe.609127
Najera, J., Chen, H., Howard, S. S., & Datta, M. (2026) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-026-00937-7
Min, C., Choe, K., Chen, X., Karagiannidis, I., Sivakumar, N., Xu, C., Melnick, A., Phillip, J. M., & Béguelin, W. (2026) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.64898/2026.09.02.748910
Challenges in mitochondrial profiling during pre-clinical studies
Afonso, G. J. M., Simões, R. F., Zemko, A., Nunes, S. M. P., Pinho, S. L. C., Oliveira, P. J., & Cunha‐Oliveira, T. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-45078-5.00002-6
Metadata
- Authors
- Hopt, A., & Neher, E.
- Affiliations
- Max Planck Institute for Biophysical Chemistry (DE)
- Max Planck Society (DE)
- Corresponding author
- Neher, Erwin
- ORCID
- Neher, Erwin
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2001-04
- Volume
- 80
- Issue
- 4
- Pages
- 2029-2036
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1301392
- OpenAlex
- W2089975180
- Cited by
- 442
- References
- 27
- Citations by year
- 2026: 15 · 2025: 15 · 2024: 15 · 2023: 16 · 2022: 23 · 2021: 21 · 2020: 16 · 2019: 14 · 2018: 14 · 2017: 18 · 2016: 16 · 2015: 18 · 2014: 24 · 2013: 18 · 2012: 13
- FWCI
- 9.13
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Nonlinear Optical Materials Studies
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Keywords
- two-photon fluorescence microscopy, photodamage, laser pulse shape, focal volume, excitation intensity, adrenal chromaffin cells, calcium imaging, degranulation
- MeSH terms
- Adrenal Glands, Animals, Calcium, Cattle, Lasers, Light, Microscopy, Fluorescence, Models, Theoretical, Time Factors, Models, Statistical, Photons, Chromaffin Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review