The DOI matches its Crossref record.
Thermoelasticity of red blood cell membrane
Open accessAbstract
The elastic properties of the human red blood cell membrane have been measured as functions of temperature. The area compressibility modulus and the elastic shear modulus, which together characterize the surface elastic behavior of the membrane, have been measured over the temperature range of 2-50 degrees C with micropipette aspiration of flaccid and osmotically swollen red cells. In addition, the fractional increase in membrane surface area from 2-50 degrees C has been measured to give a value for the thermal area expansivity. The value of the elastic shear modulus at 25 degrees C was measured to be 6.6 X 10(-3) dyne/cm. The change in the elastic shear modulus with temperature was -6 X 10(-5) dyne/cm degrees C. Fractional forces were shown to be only on the order of 10-15%. The area compressibility modulus at 25 degrees C was measured to be 450 dyne/cm. The change in the area compressibility modulus with temperature was -6 dyne/cm degrees C. The thermal area expansivity for red cell membrane was measured to be 1.2 X 10(-3)/degrees C. With this data and thermoelastic relations the heat of expansion is determined to be 110-200 ergs/cm2; the heat of extension is 2 X 10(-2) ergs/cm2 for unit extension of the red cell membrane. The heat of expansion is of the order anticipated for a lipid bilayer idealized as twice the behavior of a monolayer at an oil-water interface. The observation that the heat of extension is positive demonstrates that the entropy of the material increases with extension, and that the dominant mechanism of elastic energy storage is energetic. Assuming that the red cell membrane shear rigidity is associated with "spectrin," unit extension of the membrane increases the configurational entropy of spectrin by 500 cal/mol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Configurations of fluid membranes and vesicles
Seifert, U. (1997) · Advances in Physics · doi:10.1080/00018739700101488 · Cited by 1,650
Optical tweezers for single cells
Zhang, H., & Liu, K.-K. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0052 · Cited by 768
A New Determination of the Shear Modulus of the Human Erythrocyte Membrane Using Optical Tweezers
Hénon, S., Lenormand, G., Richert, A., & Gallet, F. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77279-6 · Cited by 577
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Biomechanical properties of red blood cells in health and disease towards microfluidics
Tomaiuolo, G. (2014) · Biomicrofluidics · doi:10.1063/1.4895755 · Cited by 368
Metadata
- Authors
- Waugh, R., & Evans, E. A.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1979-04
- Volume
- 26
- Issue
- 1
- Pages
- 115-131
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1981054060
- Cited by
- 427
- References
- 0
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermoelasticity of red blood cell membrane. https://app.cochat.ai/papers/10.1016/s0006-3495(79)85239-x
- The paper
- Waugh, R., & Evans, E. A. (1979). Thermoelasticity of red blood cell membrane. Biophysical Journal. https://doi.org/10.1016/s0006-3495(79)85239-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.