Thermoelasticity of red blood cell membrane
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The elastic properties of the human red blood cell membrane have been measured as functions of temperature. The area compressibility modulus and the elastic shear modulus, which together characterize the surface elastic behavior of the membrane, have been measured over the temperature range of 2-50 degrees C with micropipette aspiration of flaccid and osmotically swollen red cells. In addition, the fractional increase in membrane surface area from 2-50 degrees C has been measured to give a value for the thermal area expansivity. The value of the elastic shear modulus at 25 degrees C was measured to be 6.6 X 10(-3) dyne/cm. The change in the elastic shear modulus with temperature was -6 X 10(-5) dyne/cm degrees C. Fractional forces were shown to be only on the order of 10-15%. The area compressibility modulus at 25 degrees C was measured to be 450 dyne/cm. The change in the area compressibility modulus with temperature was -6 dyne/cm degrees C. The thermal area expansivity for red cell membrane was measured to be 1.2 X 10(-3)/degrees C. With this data and thermoelastic relations the heat of expansion is determined to be 110-200 ergs/cm2; the heat of extension is 2 X 10(-2) ergs/cm2 for unit extension of the red cell membrane. The heat of expansion is of the order anticipated for a lipid bilayer idealized as twice the behavior of a monolayer at an oil-water interface. The observation that the heat of extension is positive demonstrates that the entropy of the material increases with extension, and that the dominant mechanism of elastic energy storage is energetic. Assuming that the red cell membrane shear rigidity is associated with "spectrin," unit extension of the membrane increases the configurational entropy of spectrin by 500 cal/mol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THE ORGANIZATION OF PROTEINS IN THE HUMAN RED BLOOD CELL MEMBRANE
Steck, T. L. (1974) · The Journal of Cell Biology · doi:10.1083/jcb.62.1.1 · Cited by 1,552
Strain Energy Function of Red Blood Cell Membranes
Skalak, R., Tozeren, A., Zarda, R. P., & Chien, S. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)85983-1 · Cited by 832
Bending Resistance and Chemically Induced Moments in Membrane Bilayers
Evans, E. A. (1974) · Biophysical Journal · doi:10.1016/s0006-3495(74)85959-x · Cited by 682
Self-citationElastic area compressibility modulus of red cell membrane
Evans, E. A., Waugh, R., & Melnik, L. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85713-x · Cited by 463
Self-citationEvans, E. A. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86036-9 · Cited by 391
Self-citationMeasurement of the Elastic Modulus for Red Cell Membrane Using a Fluid Mechanical Technique
Hochmuth, R. M., Mohandas, N., & Blackshear, P. L. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86021-7 · Cited by 310
Bennett, V., & Branton, D. (1977) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)40522-9 · Cited by 296
Cited by
Configurations of fluid membranes and vesicles
Seifert, U. (1997) · Advances in Physics · doi:10.1080/00018739700101488 · Cited by 1,650
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423
Lipowsky, R. (1991) · Nature · doi:10.1038/349475a0 · Cited by 978
Optical tweezers for single cells
Zhang, H., & Liu, K.-K. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0052 · Cited by 768
Park, Y., Diez-Silva, M., Popescu, G., Lykotrafitis, G., Choi, W., Feld, M. S., & Suresh, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806100105 · Cited by 689
A Multiscale Red Blood Cell Model with Accurate Mechanics, Rheology, and Dynamics
Fedosov, D. A., Caswell, B., & Karniadakis, G. E. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.02.002 · Cited by 618
A New Determination of the Shear Modulus of the Human Erythrocyte Membrane Using Optical Tweezers
Hénon, S., Lenormand, G., Richert, A., & Gallet, F. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77279-6 · Cited by 577
Thermoelasticity of large lecithin bilayer vesicles
Kwok, R., & Evans, E. (1981) · Biophysical Journal · doi:10.1016/s0006-3495(81)84817-5 · Cited by 510
Self-citationEvans, E. A. (1983) · Biophysical Journal · doi:10.1016/s0006-3495(83)84319-7 · Cited by 433
Self-citationMicroengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Biomechanical properties of red blood cells in health and disease towards microfluidics
Tomaiuolo, G. (2014) · Biomicrofluidics · doi:10.1063/1.4895755 · Cited by 368
Simulations of the Erythrocyte Cytoskeleton at Large Deformation. II. Micropipette Aspiration
Discher, D. E., Boal, D. H., & Boey, S. K. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74076-7 · Cited by 354
Numerical Simulation of Flowing Blood Cells
Freund, J. B. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141349 · Cited by 323
Sorting of Lipids and Proteins in Membrane Curvature Gradients
Tian, A., & Baumgart, T. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2008.11.067 · Cited by 291
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Thermomechanical and transition properties of dimyristoylphosphatidylcholine/cholesterol bilayers
Needham, D., McIntosh, T. J., & Evans, E. (1988) · Biochemistry · doi:10.1021/bi00413a013 · Cited by 275
Self-citationRed cell extensional recovery and the determination of membrane viscosity
Hochmuth, R. M., Worthy, P. R., & Evans, E. A. (1979) · Biophysical Journal · doi:10.1016/s0006-3495(79)85238-8 · Cited by 264
Self-citationIntroductory biomechanics: from cells to organisms
(2007) · Choice Reviews Online · doi:10.5860/choice.45-1476 · Cited by 241
Thermoelectrics for medical applications: Progress, challenges, and perspectives
Hu, B., Shi, X.-L., Zou, J., & Chen, Z.-G. (2022) · Chemical Engineering Journal · doi:10.1016/j.cej.2022.135268 · Cited by 220
Review on Cell Mechanics: Experimental and Modeling Approaches
Rodriguez, M. L., McGarry, P. J., & Sniadecki, N. J. (2013) · Applied Mechanics Reviews · doi:10.1115/1.4025355 · Cited by 218
Coalescence of Membrane Tethers: Experiments, Theory, and Applications
Cuvelier, D., Derényi, I., Bassereau, P., & Nassoy, P. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.056473 · Cited by 207
“Membrane tension s was computed from the formula (Waugh and Evans, 1979): s ¼ DP Rp 2ð1 Rp=RvÞ ; (1) where DP is the applied suction pressure, Rp is the inner radius of the pipette, and Rv is the radius of the portion of the vesicle outside of the pipette.”
MethodMills, J. P., Diez-Silva, M., Quinn, D. J., Dao, M., Lang, M. J., Tan, K. S. W., Lim, C. T., Milon, G., David, P. H., Mercereau-Puijalon, O., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703433104 · Cited by 206
Kim, J., Tchelepi, H. A., & Juanes, R. (2011) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2011.02.011 · Cited by 200
“Coupling of flow and mechanics has farreaching consequences for soft tissues such as blood cells [2] and the brain, whose mechanical response depends critically on hydration [3].”
Background[1] Structure and deformation properties of red blood cells: Concepts and quantitative methods
Evans, E. A. (1989) · Methods in Enzymology · doi:10.1016/s0076-6879(89)73003-2 · Cited by 196
Self-citationLipid bilayer and cytoskeletal interactions in a red blood cell
Peng, Z., Li, X., Pivkin, I. V., Dao, M., Karniadakis, G. E., & Suresh, S. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1311827110 · Cited by 194
“Using the twocomponent DPDmodel we are able to simulate, with the same set of input mechanical parameters, micropipette experiments that provide estimates of the area modulus (kl shown in SI Text) of the lipid bilayer (22) as well as the area and shear moduli (ks and μs shown in SI Text) of the cytoskeleton (12, 23).”
BackgroundMethodAdhesively-Tensed Cell Membranes: Lysis Kinetics and Atomic Force Microscopy Probing
Hategan, A., Law, R., Kahn, S., & Discher, D. E. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74697-9 · Cited by 187
“…cells since they are known to experience large, rate-dependent deformations in blood flow which have long motivated investigations by micropipette aspiration (e.g., Evans and Skalak, 1980; Discher et al., 1998; Waugh and Evans, 1979) or optical tweezers (Henon et al., 1999; Lenormand et al., 2001).”
Dimova, R., Pouligny, B., & Dietrich, C. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76296-5 · Cited by 184
“On the other hand, when frozen or when subjected to a large deformation, the biological membrane exhibits an elastic response (Hochmuth et al., 1980; Waugh and Evans, 1979) (the red blood cell membrane has often been modeled as a thin rubber sheet; see, for instance, Skalak et al.”
BackgroundAdvances in the measurement of red blood cell deformability: A brief review
Kim, J., Lee, H., & Shin, S. (2015) · Journal of Cellular Biotechnology · doi:10.3233/jcb-15007 · Cited by 178
“Because membrane fluctuation is closely correlated with deformability in RBCs [57], analysis of dynamic fluctuation can be used to determine the bending modulus and tension factor of RBCs [54].”
Membrane tension: A challenging but universal physical parameter in cell biology
Pontes, B., Monzo, P., & Gauthier, N. C. (2017) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2017.08.030 · Cited by 176
“The cells deformed until the stress exceeded a critical point, after which RBCs 64 began to form tubes of membrane from the connection to their substrate.”
MethodInfluentialSimulations of the Erythrocyte Cytoskeleton at Large Deformation. I. Microscopic Models
Boey, S. K., Boal, D. H., & Discher, D. E. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)74075-5 · Cited by 169
“The in-plane elastic constants of the network—shear and area compression moduli— have been measured at vanishingly small (Zilker et al., 1992; Peterson et al., 1992; Strey et al., 1995) and moderate ( Waugh and Evans, 1979; Hochmuth, 1987; Engelhardt and Sackmann, 1988; Discher et al., 1994) stress.”
BackgroundInfluentialMacMECCAN, R. M., CLAUSEN, J. R., NEITZEL, G. P., & AIDUN, C. K. (2009) · Journal of Fluid Mechanics · doi:10.1017/s0022112008004011 · Cited by 166
“The RBC membrane has an effective elastic shear modulus of 5.7 × 10−3 dyn cm−1 (Waugh & Evans 1979) and a bending stiffness of 2.2 × 10−12 dyn cm (Hwang & Waugh 1997).”
BackgroundMethodInfluential
Metadata
- Authors
- Waugh, R., & Evans, E. A.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1979-04
- Volume
- 26
- Issue
- 1
- Pages
- 115-131
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1981054060
- Cited by
- 427
- References
- 7
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.