Determination of bilayer membrane bending stiffness by tether formation from giant, thin-walled vesicles
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The curvature elastic modulus (bending stiffness) of stearoyloleoyl phosphatidylcholine (SOPC) bilayer membrane is determined from membrane tether formation experiments. R. E. Waugh and R. M. Hochmuth 1987. Biophys. J. 52:391-400) have shown that the radius of a bilayer cylinder (tether) is inversely related to the force supported along its axis. The coefficient that relates the axial force on the tether to the tether radius is the membrane bending stiffness. Thus, the bending stiffness can be calculated directly from measurements of the tether radius as a function of force. Giant (10-50-microns diam) thin-walled vesicles were aspirated into a micropipette and a tether was pulled out of the surface by gravitational forces on small glass beads that had adhered to the vesicle surface. Because the vesicle keeps constant surface area and volume, formation of the tether requires displacement of material from the projection of the vesicle in the pipette. Tethers can be made to grow longer or shorter or to maintain equilibrium by adjusting the aspiration pressure in the micropipette at constant tether force. The ratio of the change in the length of the tether to the change in the projection length is proportional to the ratio of the pipette radius to the tether radius. Thus, knowing the density and diameter of the glass beads and measuring the displacement of the projection as a function of tether length, independent determinations of the force on the tether and the tether radius were obtained. The bending stiffness for an SOPC bilayer obtained from these data is approximately 2.0 x 10(-12) dyn cm, for tether radii in the range of 20-100 nm. An equilibrium relationship between pressure and tether force is derived which closely matches experimental observation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation and properties of thin‐walled phospholipid vesicles
Reeves, J. P., & Dowben, R. M. (1969) · Journal of Cellular Physiology · doi:10.1002/jcp.1040730108 · Cited by 656
Elastic area compressibility modulus of red cell membrane
Evans, E. A., Waugh, R., & Melnik, L. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85713-x · Cited by 463
Self-citationEvans, E. A. (1983) · Biophysical Journal · doi:10.1016/s0006-3495(83)84319-7 · Cited by 433
Measurement of the Elastic Modulus for Red Cell Membrane Using a Fluid Mechanical Technique
Hochmuth, R. M., Mohandas, N., & Blackshear, P. L. (1973) · Biophysical Journal · doi:10.1016/s0006-3495(73)86021-7 · Cited by 310
Measurement of the curvature-elastic modulus of egg lecithin bilayers
Servuss, R. M., Harbich, V., & Helfrich, W. (1976) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/0005-2736(76)90422-3 · Cited by 196 · cited 1×
“(This result is not unique to the thick liquid shell model used by Waugh and Hochmuth, 1987. An identical relationship can be obtained using an energy-variational analysis of a thin cylindrical membrane with negligible surface shear rigidity, constant surface area, and finite curvature elasticity.) Thus, measurements…”
MethodThermal fluctuations of large cylindrical phospholipid vesicles
Schneider, M. B., Jenkins, J. T., & Webb, W. W. (1984) · Biophysical Journal · doi:10.1016/s0006-3495(84)84235-6 · Cited by 171
Extensional flow of erythrocyte membrane from cell body to elastic tether. II. Experiment
Hochmuth, R. M., Wiles, H. C., Evans, E. A., & McCown, J. T. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84493-7 · Cited by 159 · cited 2×
“In previous mechanical analyses of membrane tether formation (Waugh, 1982; Hochmuth and Evans, 1982) the membrane was treated as a thin shell with negligible bending stiffness.”
MethodMechanical equilibrium of thick, hollow, liquid membrane cylinders
Waugh, R. E., & Hochmuth, R. M. (1987) · Biophysical Journal · doi:10.1016/s0006-3495(87)83227-7 · Cited by 137 · cited 1×
“As a result, it leads to a major discontinuity in the membrane force resultants at the vesicle-tether junction (Waugh and Hochmuth, 1987).”
BackgroundSelf-citationExtensional flow of erythrocyte membrane from cell body to elastic tether. I. Analysis
Hochmuth, R. M., & Evans, E. A. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84492-5 · Cited by 98
Surface viscosity measurements from large bilayer vesicle tether formation. I. Analysis
Waugh, R. E. (1982) · Biophysical Journal · doi:10.1016/s0006-3495(82)84526-8 · Cited by 65
Self-citation
Cited by
Effect of Chain Length and Unsaturation on Elasticity of Lipid Bilayers
Rawicz, W., Olbrich, K. C., McIntosh, T., Needham, D., & Evans, E. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76295-3 · Cited by 1,932
Configurations of fluid membranes and vesicles
Seifert, U. (1997) · Advances in Physics · doi:10.1080/00018739700101488 · Cited by 1,650
Seifert, U., Berndl, K., & Lipowsky, R. (1991) · Physical Review A · doi:10.1103/physreva.44.1182 · Cited by 963
Cellular motions and thermal fluctuations: the Brownian ratchet
Peskin, C. S., Odell, G. M., & Oster, G. F. (1993) · Biophysical Journal · doi:10.1016/s0006-3495(93)81035-x · Cited by 889
Use the force: membrane tension as an organizer of cell shape and motility
Diz-Muñoz, A., Fletcher, D. A., & Weiner, O. D. (2013) · Trends in Cell Biology · doi:10.1016/j.tcb.2012.09.006 · Cited by 574
Metadata
- Authors
- Bo, L., & Waugh, R. E.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1989-03
- Volume
- 55
- Issue
- 3
- Pages
- 509-517
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2020152035
- Cited by
- 212
- References
- 10
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.