Pulsed laser imaging of rapid Ca2+ gradients in excitable cells
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Excitable cells are thought to respond to action potentials by forming short lived and highly localized Ca2+ gradients near sites of Ca2+ entry or near the site of Ca2+ release by intracellular stores. However, conventional imaging techniques lack the spatial and temporal resolution to capture these gradients. Here we demonstrate the use of pulsed-laser microscopy to measure Ca2+ gradients with submicron spatial resolution and millisecond time resolution in two preparations where the Ca2+ signal is thought to be fast and highly localized: adrenal chromaffin cells, where the entry of Ca2+ through voltage dependent Ca2+ channels triggers exocytotic fusion; and skeletal muscle fibers, where intracellular Ca2+ release from the sarcoplasmic reticulum initiates contraction. In chromaffin cells, Ca2+ gradients developed over 10-100 ms and were initially restricted to discrete submembrane domains, or hot spots, before developing into complete rings of elevated Ca2+ concentration. In frog skeletal muscle large, short-lived (approximately 6 ms) Ca2+ gradients were observed within individual sarcomeres following induction of action potentials. The pulsed laser imaging approach permits, for the first time, the capture and critical examination of rapid Ca2+ signaling events such as those underlying excitation-secretion and excitation-contraction coupling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
[6] Correction for liquid junction potentials in patch clamp experiments
Neher, E. (1992) · Methods in Enzymology · doi:10.1016/0076-6879(92)07008-c · Cited by 1,132
Sodium and calcium channels in bovine chromaffin cells
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014394 · Cited by 961
Cited by
AN INTRODUCTION TO TRP CHANNELS
Ramsey, I. S., Delling, M., & Clapham, D. E. (2006) · Annual Review of Physiology · doi:10.1146/annurev.physiol.68.040204.100431 · Cited by 1,551
Burgoyne, R. D., & Morgan, A. (2003) · Physiological Reviews · doi:10.1152/physrev.00031.2002 · Cited by 934
Measurement of Intracellular Calcium
Takahashi, A., Camacho, P., Lechleiter, J. D., & Herman, B. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.4.1089 · Cited by 763
Guiding neuronal growth cones using Ca 2+ signals
Henley, J., & Poo, M.-M. (2004) · Trends in Cell Biology · doi:10.1016/j.tcb.2004.04.006 · Cited by 365
Calcium signaling and exocytosis in adrenal chromaffin cells
García, A. G., García-De-Diego, A. M., Gandía, L., Borges, R., & García-Sancho, J. (2006) · Physiological Reviews · doi:10.1152/physrev.00039.2005 · Cited by 349
Metadata
- Authors
- Monck, J. R., Robinson, I. M., Escobar, A. L., Vergara, J. L., & Fernandez, J. M.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1994-08
- Volume
- 67
- Issue
- 2
- Pages
- 505-514
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W1975246201
- Cited by
- 85
- References
- 2
- FWCI
- 6.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulsed laser imaging of rapid Ca2+ gradients in excitable cells. https://app.cochat.ai/papers/10.1016/s0006-3495(94)80554-5
- The paper
- Monck, J. R., Robinson, I. M., Escobar, A. L., Vergara, J. L., & Fernandez, J. M. (1994). Pulsed laser imaging of rapid Ca2+ gradients in excitable cells. Biophysical Journal. https://doi.org/10.1016/s0006-3495(94)80554-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.