The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Sensitive force technique to probe molecular adhesion and structural linkages at biological interfaces
Open accessAbstract
Adhesion and cytoskeletal structure are intimately related in biological cell function. Even with the vast amount of biological and biochemical data that exist, little is known at the molecular level about physical mechanisms involved in attachments between cells or about consequences of adhesion on the material structure. To expose physical actions at soft biological interfaces, we have combined an ultrasensitive transducer and reflection interference microscopy to image submicroscopic displacements of probe contact with a test surface under minuscule forces. The transducer is a cell-size membrane capsule pressurized by micropipette suction where displacement normal to the membrane under tension is proportional to the applied force. Pressure control of the tension tunes the sensitivity in operation over four orders of magnitude through a range of force from 0.01 pN up to the strength of covalent bonds (approximately 1000 pN)! As the surface probe, a microscopic bead is biochemically glued to the transducer with a densely-bound ligand that is indifferent to the test surface. Movements of the probe under applied force are resolved down to an accuracy of approximately 5 nm from the interference fringe pattern created by light reflected from the bead. With this arrangement, we show that local mechanical compliance of a cell surface can be measured at a displacement resolution set by structural fluctuations. When desired, a second ligand is bound sparsely to the probe for focal adhesion to specific receptors in the test surface. We demonstrate that monitoring fluctuations in probe position at low transducer stiffness enhances detection of molecular adhesion and activation of cytoskeletal structure. Subsequent loading of an attachment tests mechanical response of the receptor-substrate linkage throughout the force-driven process of detachment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adhesion receptors of the immune system
Springer, T. A. (1990) · Nature · doi:10.1038/346425a0 · Cited by 6,477
Cited by
Molecular interaction and inhibition of SARS-CoV-2 binding to the ACE2 receptor
Yang, J., Petitjean, S. J. L., Koehler, M., Zhang, Q., Dumitru, A. C., Chen, W., Derclaye, S., Vincent, S. P., Soumillion, P., & Alsteens, D. (2020) · Nature Communications · doi:10.1038/s41467-020-18319-6 · Cited by 615
Izrailev, S., Stepaniants, S., Isralewitz, B., Kosztin, D., Lu, H., Molnar, F., Wriggers, W., & Schulten, K. (1999) · Lecture Notes in Computational Science and Engineering · doi:10.1007/978-3-642-58360-5_2 · Cited by 451
Ribas-Arino, J., & Marx, D. (2012) · Chemical Reviews · doi:10.1021/cr200399q · Cited by 448
Measuring elasticity of biological materials by atomic force microscopy
Vinckier, A., & Semenza, G. (1998) · FEBS Letters · doi:10.1016/s0014-5793(98)00592-4 · Cited by 386
Spatially resolved force spectroscopy of biological surfaces using the atomic force microscope
Heinz, W. F., & Hoh, J. H. (1999) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01304-9 · Cited by 373
Metadata
- Authors
- Evans, E., Ritchie, K., & Merkel, R.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1995-06
- Volume
- 68
- Issue
- 6
- Pages
- 2580-2587
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2005149945
- Cited by
- 538
- References
- 1
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitive force technique to probe molecular adhesion and structural linkages at biological interfaces. https://app.cochat.ai/papers/10.1016/s0006-3495(95)80441-8
- The paper
- Evans, E., Ritchie, K., & Merkel, R. (1995). Sensitive force technique to probe molecular adhesion and structural linkages at biological interfaces. Biophysical Journal. https://doi.org/10.1016/s0006-3495(95)80441-8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.