The DOI matches its Crossref record.
Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors
Open accessAbstract
A newly developed water-soluble phosphor suitable for measuring oxygen pressure in the blood (Green 2W) was used for noninvasive, in vivo imaging of oxygen distribution in the vascular systems of mice. Oxygen quenches the phosphorescence of Green 2W, measured in the presence of 2% albumin, according to the Stern-volmer relationship. This oxygen-dependent quenching of phosphorescence has been used to obtain digital maps of the oxygen distribution in the tissue vasculature. EMT-6 mammary carcinoma tumors were grown by injecting 1 x 10(6) cells in 0.1-ml carrier into the subcutaneous space over the muscle on the hindquarter. When the tumors were approximately 8 mm in diameter, 300 micrograms of phosphorescence probe (Green 2W; absorption maximum 636 nm) was injected into the tail vein. The mice were immobilized with intraperotoneal Ketamine (133 mg/kg) and Xylazine (10 mg/kg) and illuminated with flashes (< 4-microseconds t1/2) of light of 630 +/- 12 nm. The emitted phosphorescence (790-nm maximum) was imaged an intensified CCD camera. Images were collected beginning at 30, 50, 80, 120, 180, 240, 420, and 2500 microseconds after the flash and used to calculate digital maps of the phosphorescence lifetimes and oxygen pressure. Both the illumination light and the phosphorescence were in the near-infrared region of the spectrum, where tissue has greatly decreased absorbance. The light therefore readily passed through the skin and centimeter thicknesses of tissue. The oxygen maps could be obtained by illuminating from the side of the mouse opposite the camera (and tumor). The tumors were readily observed as regions with oxygen pressures substantially below those of the surrounding tissue. Thus, phosphorescence measurements can noninvasively detect volumes of tissue with below-normal oxygen pressure in the presence of much larger volumes of tissue with normal oxygen pressures. In addition, tissue oxygen pressures can be monitored in real time, even through centimeter thicknesses of tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Correlation between intraluminal oxygen gradient and radial partitioning of intestinal microbiota
Albenberg, L., Esipova, T. V., Judge, C. P., Bittinger, K., Chen, J., Laughlin, A., Grunberg, S., Baldassano, R. N., Lewis, J. D., Li, H., et al. (2014) · Gastroenterology · doi:10.1053/j.gastro.2014.07.020 · Cited by 886
Self-citationImplicit and explicit dosimetry in photodynamic therapy: a New paradigm
Wilson, B. C., Patterson, M. S., & Lilge, L. (1997) · Lasers in Medical Science · doi:10.1007/bf02765099 · Cited by 411
Zhang, S., Hosaka, M., Yoshihara, T., Negishi, K., Iida, Y., Tobita, S., & Takeuchi, T. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-3948 · Cited by 349
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Metadata
- Authors
- Vinogradov, S. A., Lo, L. W., Jenkins, W. T., Evans, S. M., Koch, C., & Wilson, D. F.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1996-04
- Volume
- 70
- Issue
- 4
- Pages
- 1609-1617
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2060238620
- Cited by
- 175
- References
- 0
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors. https://app.cochat.ai/papers/10.1016/s0006-3495(96)79764-3
- The paper
- Vinogradov, S. A., Lo, L. W., Jenkins, W. T., Evans, S. M., Koch, C., & Wilson, D. F. (1996). Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors. Biophysical Journal. https://doi.org/10.1016/s0006-3495(96)79764-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.