Noninvasive imaging of the distribution in oxygen in tissue in vivo using near-infrared phosphors
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
A newly developed water-soluble phosphor suitable for measuring oxygen pressure in the blood (Green 2W) was used for noninvasive, in vivo imaging of oxygen distribution in the vascular systems of mice. Oxygen quenches the phosphorescence of Green 2W, measured in the presence of 2% albumin, according to the Stern-volmer relationship. This oxygen-dependent quenching of phosphorescence has been used to obtain digital maps of the oxygen distribution in the tissue vasculature. EMT-6 mammary carcinoma tumors were grown by injecting 1 x 10(6) cells in 0.1-ml carrier into the subcutaneous space over the muscle on the hindquarter. When the tumors were approximately 8 mm in diameter, 300 micrograms of phosphorescence probe (Green 2W; absorption maximum 636 nm) was injected into the tail vein. The mice were immobilized with intraperotoneal Ketamine (133 mg/kg) and Xylazine (10 mg/kg) and illuminated with flashes (< 4-microseconds t1/2) of light of 630 +/- 12 nm. The emitted phosphorescence (790-nm maximum) was imaged an intensified CCD camera. Images were collected beginning at 30, 50, 80, 120, 180, 240, 420, and 2500 microseconds after the flash and used to calculate digital maps of the phosphorescence lifetimes and oxygen pressure. Both the illumination light and the phosphorescence were in the near-infrared region of the spectrum, where tissue has greatly decreased absorbance. The light therefore readily passed through the skin and centimeter thicknesses of tissue. The oxygen maps could be obtained by illuminating from the side of the mouse opposite the camera (and tumor). The tumors were readily observed as regions with oxygen pressures substantially below those of the surrounding tissue. Thus, phosphorescence measurements can noninvasively detect volumes of tissue with below-normal oxygen pressure in the presence of much larger volumes of tissue with normal oxygen pressures. In addition, tissue oxygen pressures can be monitored in real time, even through centimeter thicknesses of tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An optical method for measurement of dioxygen concentration based upon quenching of phosphorescence.
Vanderkooi, J. M., Maniara, G., Green, T. J., & Wilson, D. F. (1987) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)45596-2 · Cited by 592
Self-citationImaging of phosphorescence: a novel method for measuring oxygen distribution in perfused tissue
Rumsey, W., Vanderkooi, J., & Wilson, D. (1988) · Science · doi:10.1126/science.241.4873.1649 · Cited by 534
Self-citationvan der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Wilson, D. F., Rumsey, W. L., Green, T. J., & Vanderkooi, J. M. (1988) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)69126-4 · Cited by 387
Self-citationRumsey, W. L., Schlosser, C., Nuutinen, E. M., Robiolio, M., & Wilson, D. F. (1990) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)55409-0 · Cited by 211
Self-citationMicrovessel PO2 measurements by phosphorescence decay method
Filho, I. P. T., & Intaglietta, M. (1993) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1993.265.4.h1434 · Cited by 153
Localization of tumors and evaluation of their state of oxygenation by phosphorescence imaging.
Wilson, D. F., & Cerniglia, G. J. (1992) · PubMed · Cited by 101
Self-citationPawlowski, M., & Wilson, D. F. (1992) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-3404-4_21 · Cited by 92
Self-citationOxygen diffusion and mitochondrial respiration in neuroblastoma cells
Robiolio, M., Rumsey, W. L., & Wilson, D. F. (1989) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1989.256.6.c1207 · Cited by 77
Self-citationShonat, R. D., Wilson, D. F., Riva, C. E., & Cranstoun, S. D. (1992) · PubMed · Cited by 72
Self-citation
Cited by
Singlet oxygen: there is indeed something new under the sun
Ogilby, P. R. (2010) · Chemical Society Reviews · doi:10.1039/b926014p · Cited by 1,266
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Conductive Polymers: Opportunities and Challenges in Biomedical Applications
Nezakati, T., Seifalian, A., Tan, A., & Seifalian, A. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00275 · Cited by 977
Vascularization Strategies for Tissue Engineering
Lovett, M., Lee, K., Edwards, A., & Kaplan, D. L. (2009) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2009.0085 · Cited by 923
Correlation between intraluminal oxygen gradient and radial partitioning of intestinal microbiota
Albenberg, L., Esipova, T. V., Judge, C. P., Bittinger, K., Chen, J., Laughlin, A., Grunberg, S., Baldassano, R. N., Lewis, J. D., Li, H., et al. (2014) · Gastroenterology · doi:10.1053/j.gastro.2014.07.020 · Cited by 886
“Similar changes in tissue PO2 levels upon inhalation of pure oxygen have been observed previously in other tissues.(31) Remarkably, inhalation of pure oxygen also led to an increase in the luminal PO2, which decreased upon return to ambient air.”
BackgroundSelf-citationCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
Implicit and explicit dosimetry in photodynamic therapy: a New paradigm
Wilson, B. C., Patterson, M. S., & Lilge, L. (1997) · Lasers in Medical Science · doi:10.1007/bf02765099 · Cited by 411
Ratiometric Single‐Nanoparticle Oxygen Sensors for Biological Imaging
Wu, C., Bull, B., Christensen, K., & McNeill, J. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805894 · Cited by 378
Zhang, S., Hosaka, M., Yoshihara, T., Negishi, K., Iida, Y., Tobita, S., & Takeuchi, T. (2010) · Cancer Research · doi:10.1158/0008-5472.can-09-3948 · Cited by 349
Hawrysz, D. J., & Sevick-Muraca, E. M. (2000) · Neoplasia · doi:10.1038/sj.neo.7900118 · Cited by 340
Oxyphor R2 and G2: phosphors for measuring oxygen by oxygen-dependent quenching of phosphorescence
Dunphy, I., Vinogradov, S. A., & Wilson, D. F. (2002) · Analytical Biochemistry · doi:10.1016/s0003-2697(02)00384-6 · Cited by 288
Self-citationPhosphorescent Oxygen Sensor with Dendritic Protection and Two-Photon Absorbing Antenna
Briñas, R. P., Troxler, T., Hochstrasser, R. M., & Vinogradov, S. A. (2005) · Journal of the American Chemical Society · doi:10.1021/ja052947c · Cited by 267
Self-citationPeer Reviewed: Oxygen Sensors Based on Luminescence Quenching.
Demas, J. N., DeGraff, B. A., & Coleman, P. B. (1999) · Analytical Chemistry · doi:10.1021/ac9908546 · Cited by 263
Two New “Protected” Oxyphors for Biological Oximetry: Properties and Application in Tumor Imaging
Esipova, T. V., Karagodov, A., Miller, J., Wilson, D. F., Busch, T. M., & Vinogradov, S. A. (2011) · Analytical Chemistry · doi:10.1021/ac2022234 · Cited by 247
Self-citationDendritic Phosphorescent Probes for Oxygen Imaging in Biological Systems
Lebedev, A. Y., Cheprakov, A. V., Sakadžić, S., Boas, D. A., Wilson, D. F., & Vinogradov, S. A. (2009) · ACS Applied Materials & Interfaces · doi:10.1021/am9001698 · Cited by 231
Self-citationAssessment of tumor oxygenation by electron paramagnetic resonance: principles and applications
Gallez, B., Baudelet, C., & Jordan, B. F. (2004) · NMR in Biomedicine · doi:10.1002/nbm.900 · Cited by 222
Recent progress and applications for metallodendrimers
Hwang, S.-H., Shreiner, C. D., Moorefield, C. N., & Newkome, G. R. (2007) · New Journal of Chemistry · doi:10.1039/b612656c · Cited by 203
Dewhirst, M. W., Ong, E. T., Braun, R. D., Smith, B., Klitzman, B., Evans, S. M., & Wilson, D. (1999) · British Journal of Cancer · doi:10.1038/sj.bjc.6690273 · Cited by 187
“Details of these methods have been publi previously (Wilson et al, 1992; Vinogradov et al, 1996; Cerni et al, 1997).”
Self-citationOxygen‐Sensing Methods in Biomedicine from the Macroscale to the Microscale
Roussakis, E., Li, Z., Nichols, A. J., & Evans, C. L. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201410646 · Cited by 184
Tumor Hypoxia as a Barrier in Cancer Therapy: Why Levels Matter
Hompland, T., Fjeldbo, C. S., & Lyng, H. (2021) · Cancers · doi:10.3390/cancers13030499 · Cited by 179
“In a preclinical setting, optical pO2 imaging based on oxygen induced quenching of phosphorescence, is an exciting approach (Figure 4A) [45].”
BackgroundOptical Oxygen Sensors for Applications in Microfluidic Cell Culture
Grist, S. M., Chrostowski, L., & Cheung, K. C. (2010) · Sensors · doi:10.3390/s101009286 · Cited by 169
“For excitation spectrum versatility and compatibility with other systems such as fluorescent microscopes, filtered broader-spectrum sources such as Xenon flash lamps and mercury-arc lamps have also been used [46-51,52,56,83,100-103,105,136].”
BackgroundMethodInfluential
Metadata
- Authors
- Vinogradov, S. A., Lo, L. W., Jenkins, W. T., Evans, S. M., Koch, C., & Wilson, D. F.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1996-04
- Volume
- 70
- Issue
- 4
- Pages
- 1609-1617
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2060238620
- Cited by
- 175
- References
- 13
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.