A Continuous-Flow Capillary Mixing Method to Monitor Reactions on the Microsecond Time Scale
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A continuous-flow capillary mixing apparatus, based on the original design of Regenfuss et al. (Regenfuss, P., R. M. Clegg, M. J. Fulwyler, F. J. Barrantes, and T. M. Jovin. 1985. Rev. Sci. Instrum. 56:283-290), has been developed with significant advances in mixer design, detection method and data analysis. To overcome the problems associated with the free-flowing jet used for observation in the original design (instability, optical artifacts due to scattering, poor definition of the geometry), the solution emerging from the capillary is injected directly into a flow-cell joined to the tip of the outer capillary via a ground-glass joint. The reaction kinetics are followed by measuring fluorescence versus distance downstream from the mixer, using an Hg(Xe) arc lamp for excitation and a digital camera with a UV-sensitized CCD detector for detection. Test reactions involving fluorescent dyes indicate that mixing is completed within 15 micros of its initiation and that the dead time of the measurement is 45 +/- 5 micros, which represents a >30-fold improvement in time resolution over conventional stopped-flow instruments. The high sensitivity and linearity of the CCD camera have been instrumental in obtaining artifact-free kinetic data over the time window from approximately 45 micros to a few milliseconds with signal-to-noise levels comparable to those of conventional methods. The scope of the method is discussed and illustrated with an example of a protein folding reaction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enzyme structure and mechanism
Fersht, A. (1977) · Medical Entomology and Zoology · Cited by 2,875
INTERMEDIATES IN THE FOLDING REACTIONS OF SMALL PROTEINS
Kim, P. S., & Baldwin, R. L. (1990) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.59.070190.003215 · Cited by 1,135 · cited 1×
“Methods like stopped flow and quenched flow coupled with optical detection, NMR, or electron paramagnetic resonance have been especially important for elucidating mechanisms of enzyme catalysis and protein folding (Fersht, 1985; Roder, 1989; Kuwajima et al., 1989; Kim and Baldwin, 1990; Matthews, 1993).”
MethodRoder, H., Elöve, G. A., & Englander, S. W. (1988) · Nature · doi:10.1038/335700a0 · Cited by 813 · cited 1×
“This property has been exploited in earlier studies on the folding mechanism of cyt c (Tsong, 1976; Brems and Stellwagen, 1983; Roder et al., 1988; Elöve et al., 1992, 1994; Jones et al., 1993; Colón et al., 1996).”
MethodSelf-citationMatthews, C. R. (1993) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.62.070193.003253 · Cited by 436 · cited 2×
“protein folding (Fersht, 1985; Roder, 1989; Kuwajima et al., 1989; Kim and Baldwin, 1990; Matthews, 1993 ).”
BackgroundThe barriers in protein folding
Sosnick, T. R., Mayne, L., Hiller, R., & Englander, S. W. (1994) · Nature Structural Biology · doi:10.1038/nsb0394-149 · Cited by 433
Khorasanizadeh, S., Peters, I. D., & Roder, H. (1996) · Nature Structural Biology · doi:10.1038/nsb0296-193 · Cited by 346 · cited 1×
“These submilliseond processes were largely inaccessible until recently, although their existence was implied by the observation of “missing amplitude” in SF experiments (Kuwajima et al., 1987; Elöve et al., 1992; Parker et al., 1995; Khorasanizadeh et al., 1996; Sauder et al., 1996; Park et al., 1997).”
BackgroundSelf-citationKinetic role of early intermediates in protein folding
Roder, H., & Colón, W. (1997) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(97)80004-8 · Cited by 316 · cited 1×
“In many proteins, major conformational changes are known to take place during early stages of folding (Matthews, 1993; Roder and Elöve, 1994; Ptitsyn, 1995; Miranker and Dobson, 1996; Roder and Colón, 1997).”
BackgroundSelf-citationA method of measuring the velocity of very rapid chemical reactions
Hartridge, H., & Roughton, F. J. W. (1923) · Proceedings of the Royal Society of London Series A Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1923.0116 · Cited by 314 · cited 1×
“continuous-flow (CF) and stopped-flow (SF) methods ( Hartridge and Roughton, 1923; Chance, 1940; Gibson and”
Fast events in protein folding initiated by nanosecond laser photolysis.
Jones, C. M., Henry, E. R., Hu, Y., Chan, C. K., Luck, S. D., Bhuyan, A., Roder, H., Hofrichter, J., & Eaton, W. A. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.24.11860 · Cited by 306 · cited 1×
“This property has been exploited in earlier studies on the folding mechanism of cyt c (Tsong, 1976; Brems and Stellwagen, 1983; Roder et al., 1988; Elöve et al., 1992, 1994; Jones et al., 1993; Colón et al., 1996).”
MethodSelf-citationKinetic Mechanism of Cytochrome c Folding: Involvement of the Heme and Its Ligands
Elove, G. A., Bhuyan, A. K., & Roder, H. (1994) · Biochemistry · doi:10.1021/bi00188a023 · Cited by 267
Self-citation
Cited by
Control and detection of chemical reactions in microfluidic systems
deMello, A. J. (2006) · Nature · doi:10.1038/nature05062 · Cited by 1,495
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Centrifugal microfluidics for biomedical applications
Gorkin, R., Park, J., Siegrist, J., Amasia, M., Lee, B. S., Park, J.-M., Kim, J., Kim, H., Madou, M., & Cho, Y.-K. (2010) · Lab on a Chip · doi:10.1039/b924109d · Cited by 731
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Single-Molecule Fluorescence Studies of Protein Folding and Conformational Dynamics
Michalet, X., Weiss, S., & Jäger, M. (2006) · Chemical Reviews · doi:10.1021/cr0404343 · Cited by 525
Fast Kinetics and Mechanisms in Protein Folding
Eaton, W. A., Muñoz, V., Hagen, S. J., Jas, G. S., Lapidus, L. J., Henry, E. R., & Hofrichter, J. (2000) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.29.1.327 · Cited by 488
Small-Angle X-ray Scattering of Polymers
Chu, B., & Hsiao, B. S. (2001) · Chemical Reviews · doi:10.1021/cr9900376 · Cited by 455
Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
The fundamentals of protein folding: bringing together theory and experiment
Dobson, C. M., & Karplus, M. (1999) · Current Opinion in Structural Biology · doi:10.1016/s0959-440x(99)80012-8 · Cited by 410
Changes in Biomolecular Conformation Seen by Small Angle X-ray Scattering
Doniach, S. (2001) · Chemical Reviews · doi:10.1021/cr990071k · Cited by 300
Evidence for barrier-limited protein folding kinetics on the microsecond time scale
Shastry, M. C. R., & Roder, H. (1998) · Nature Structural Biology · doi:10.1038/nsb0598-385 · Cited by 261
Self-citationApplications of micromixing technology
Jeong, G. S., Chung, S., Kim, C.-B., & Lee, S.-H. (2010) · The Analyst · doi:10.1039/b921430e · Cited by 234
Hoffmann, A., Kane, A., Nettels, D., Hertzog, D. E., Baumgärtel, P., Lengefeld, J., Reichardt, G., Horsley, D. A., Seckler, R., Bakajin, O., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604353104 · Cited by 226
T HE F AST P ROTEIN F OLDING P ROBLEM
Gruebele, M. (1999) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.50.1.485 · Cited by 203
Fluorescence Spectroscopy in Peptide and Protein Analysis
Ladokhin, A. S. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a1611 · Cited by 182
Single-molecule fluorescence detection in microfluidic channels—the Holy Grail in μTAS?
Dittrich, P. S., & Manz, A. (2005) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-005-3335-9 · Cited by 182
Early Events in Protein Folding Explored by Rapid Mixing Methods
Roder, H., Maki, K., & Cheng, H. (2006) · Chemical Reviews · doi:10.1021/cr040430y · Cited by 169
Self-citationProtein‐folding kinetics and mechanisms studied by pulse‐labeling and mass spectrometry
Konermann, L., & Simmons, D. A. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10044 · Cited by 163
Distinguishing induced fit from conformational selection
Gianni, S., Dogan, J., & Jemth, P. (2014) · Biophysical Chemistry · doi:10.1016/j.bpc.2014.03.003 · Cited by 159
“2,000-20,000 s [39] but commercial instruments are not available.”
Background
Metadata
- Authors
- Shastry, M. C. R., Luck, S. D., & Roder, H.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 1998-05
- Volume
- 74
- Issue
- 5
- Pages
- 2714-2721
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2024794991
- Cited by
- 216
- References
- 23
- FWCI
- 12.30
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.