Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 211

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Time course of arteriogenesis following femoral artery occlusion in the rabbit

Open access
Hoefer, Imo E., van Royen, Niels, Buschmann, Ivo R., Piek, Jan J., Schaper, Wolfgang · 2001 · Cardiovascular Research

Abstract

OBJECTIVE: We examined the time course of arteriogenesis (collateral artery growth) after femoral artery ligation and the effect of monocyte chemoattractant protein-1 (MCP-1). METHODS: New Zealand White rabbits received MCP-1 or phosphate buffered saline (PBS) for a 1-week period, either directly or 3 weeks after femoral artery ligation (non-ischemic model). A control group was studied with intact femoral arteries and another 1 min after acute femoral artery ligation. RESULTS: Collateral conductance index significantly increased when MCP-1 treatment started directly after femoral artery ligation (acute occlusion: 0.94+/-0.19; without occlusion: 168.56+/-15.99; PBS: 4.10+/-0.48; MCP-1: 33.96+/-1.76 ml/min/100 mmHg). However, delayed onset of treatment 3 weeks after ligation and final study of conductance at 4 weeks showed no significant difference against a 4-week control (PBS: 79.08+/-7.24; MCP-1: 90.03+/-8.73 ml/min/100 mmHg). In these groups increased conductance indices were accompanied by a decrease in the number of visible collateral vessels (from 18 to 36 identifiable vessels at day 7 to about four at 21 days). CONCLUSION: We conclude that the chemokine MCP-1 markedly accelerated collateral artery growth but did not alter its final extent above that reached spontaneously as a function of time. We show thus for the first time that a narrow time window exists for the responsiveness to the arteriogenic actions of MCP-1, a feature that MCP-1 may share with other growth factors. We show furthermore that the spontaneous adaptation by arteriogenesis stops when only about 50% of the vasodilatory reserve of the arterial bed before occlusion are reached. The superiority of few large arterial collaterals in their ability to conduct large amounts of blood flow per unit of pressure as compared to the angiogenic response where large numbers of small vessels are produced with minimal ability to allow mass transport of bulk flow is stressed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0008-6363(00)00243-1

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 211

Metadata

Authors
Hoefer, I. E., van Royen, N., Buschmann, I. R., Piek, J. J., & Schaper, W.
Venue
Cardiovascular Research
Published
2001-02-16
Volume
49
Issue
3
Pages
609-617
ISSN
  • 0008-6363 (ISSN-L)
  • 1755-3245
OpenAlex
W2171234320
Cited by
211
References
1
FWCI
6.73
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Time course of arteriogenesis following femoral artery occlusion in the rabbit. https://app.cochat.ai/papers/10.1016/s0008-6363(00)00243-1
The paper
Hoefer, I. E., van Royen, N., Buschmann, I. R., Piek, J. J., & Schaper, W. (2001). Time course of arteriogenesis following femoral artery occlusion in the rabbit. Cardiovascular Research. https://doi.org/10.1016/s0008-6363(00)00243-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.