The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Properties of the hyperpolarization-activated current (If) in isolated mouse sino-atrial cells
Open accessAbstract
OBJECTIVE: We have investigated the properties of the hyperpolarization-activated (I(f)) current in pacemaker cells from the mouse sino-atrial node (SAN). METHODS: The I(f) current was studied in cells isolated enzymatically from the SAN region of adult C57BL6/J mice. The whole-cell variation of the patch-clamp technique was employed to investigate the basic properties of I(f). RESULTS: In mouse SAN cells, the I(f) current density at -120 mV was 18+/-2 pA/pF (n=23). I(f) was not detected in cells showing atrial-like morphology that were also found in SAN preparations (n=7). I(f) was blocked by 5 mM Cs(+), was inhibited by application of 5 microM acetylcholine, and was increased by 10 microM noradrenaline. The I(f) current reversal potential was -31+/-2 mV under physiological concentration of Na(+) and K(+) ions. Lowering the extracellular Na(+) concentration reduced I(f) amplitude, while increased when the extracellular K(+) concentration was augmented. I(f) voltage for half activation was -87+/-1 mV (n=6). CONCLUSIONS: We conclude that the native I(f) current in mouse SAN cells shows functional properties that are similar to I(f) described in rabbit SAN tissue. This study opens the possibility of investigating the involvement of I(f) in the regulation of heart rate in genetically modified mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Cited by
Zamponi, G. W., Striessnig, J., Koschak, A., & Dolphin, A. C. (2015) · Pharmacological Reviews · doi:10.1124/pr.114.009654 · Cited by 1,103
Genesis and Regulation of the Heart Automaticity
Mangoni, M. E., & Nargeot, J. (2008) · Physiological Reviews · doi:10.1152/physrev.00018.2007 · Cited by 600
Self-citationAbsence epilepsy and sinus dysrhythmia in mice lacking the pacemaker channel HCN2
Ludwig, A. (2003) · The EMBO Journal · doi:10.1093/emboj/cdg032 · Cited by 534
Functional role of L-type Ca v 1.3 Ca 2+ channels in cardiac pacemaker activity
Mangoni, M. E., Couette, B., Bourinet, E., Platzer, J., Reimer, D., Striessnig, J., & Nargeot, J. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0935295100 · Cited by 467
Self-citationCNG AND HCN CHANNELS: Two Peas, One Pod
Craven, K. B., & Zagotta, W. N. (2006) · Annual Review of Physiology · doi:10.1146/annurev.physiol.68.040104.134728 · Cited by 432
Metadata
- Authors
- Mangoni, M.
- Venue
- Cardiovascular Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-10
- Volume
- 52
- Issue
- 1
- Pages
- 51-64
- ISSN
- 0008-6363 (ISSN-L)
- OpenAlex
- W2073045131
- Cited by
- 176
- References
- 1
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Properties of the hyperpolarization-activated current (If) in isolated mouse sino-atrial cells. https://app.cochat.ai/papers/10.1016/s0008-6363(01)00370-4
- The paper
- Mangoni, M. (2001). Properties of the hyperpolarization-activated current (If) in isolated mouse sino-atrial cells. Cardiovascular Research. https://doi.org/10.1016/s0008-6363(01)00370-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.