X-ray microtomography (microCT) of the progression of sulfate attack of cement paste
The DOI matches its Crossref record.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“X-ray microtomography (µCT) is another technique used to evaluate the progression of sulfate attack in cement pastes [100].”
From Sulfate attack testing approaches from concrete to cement paste: A review by RILEM TC 298-EBD (2025) · cites this paper as [100]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 16
- Mehta, 1992, Sulfate attack on concrete—a critical review, vol. III, 105
- Santhanam, 2001, Sulfate attack research—wither now?, Cem. Concr. Res., 31, 845, 10.1016/S0008-8846(01)00510-5 · DOI · Paper page
- Kinney, 1990, Nondestructive investigation of damage in composites using X-ray tomographic microscopy, J. Mater. Res., 5, 1123, 10.1557/JMR.1990.1123 · doi:10.1557/jmr.1990.1123
- T.M. Breunig, Nondestructive evaluation of damage in SiC/Al metal/matrix composite using X-ray tomographic microscopy, PhD Thesis (supervised by S.R. Stock), Georgia Institute of Technology, 1992.
- Breunig, 1993, Damage in aligned fibre SiC/Al quantified using a laboratory X-ray tomographic microscope, Composites, 24, 209, 10.1016/0010-4361(93)90165-5 · DOI
- T.M. Breunig, S.R. Stock, S.D. Antolovich, J.H. Kinney, W.N. Massey, M.C. Nichols, A framework relating macroscopic measures and physical processes of crack closure of Al–Li alloy 2090, Fracture Mechanics: Twenty-Second Symposium, Vol. 1, ASTM Spec. Tech. Publ. 1131 (1992) 749–761.
- Guvenilir, 1999, New direct observations of crack closure processes in Al–Li 2090 T8E41, Philos. Trans. R. Soc. London, 357, 2755, 10.1098/rsta.1999.0464 · doi:10.1098/rsta.1999.0464
- Morgan, 1979, Examination of concrete by computerized tomography, J. Am. Concr. Inst., 77, 23
- Martz, 1993, Computerized tomography analysis of reinforced concrete, ACI Mater. J., 90, 259
- Shah, 1999, Nondestructive techniques for studying fracture processes in concrete, Int. J. Fract., 98, 351, 10.1023/A:1018620008780 · DOI
- Landis, 1999, X-ray microtomography for fracture studies in cement-based materials, vol. 3772, 105
- Industrial Computed Tomography Topical Proceedings (1989)
- Industrial Computed Tomography II Topical Proceedings (1991), ASNT, Columbus, OH.
- Stock, 1999, Microtomography of materials, Int. Mater. Rev., 44, 141, 10.1179/095066099101528261 · DOI · Paper page
- Developments in x-ray tomography, SPIE Proc. 3149 (1997)
- Developments in x-ray tomography II, SPIE Proc. 3772 (1999).
Cited by
Sulfate attack testing approaches from concrete to cement paste: A review by RILEM TC 298-EBD
Wang, Q., Kunther, W., Li, Y., Visalakshi, T., Gomasa, R., Amroun, S., De Souza, D. J., Kasaniya, M., Tole, I., Li, X., et al. (2025) · Materials and Structures · doi:10.1617/s11527-025-02759-x · Cited by 46
Metadata
- Authors
- Stock, S. R., Naik, N. K., Wilkinson, A. P., & Kurtis, K. E.
- Venue
- Cement and Concrete Research
- Publisher
- Elsevier BV
- Published
- 2002-10
- Volume
- 32
- Issue
- 10
- Pages
- 1673-1675
- ISSN
- 0008-8846
- Cited by
- 83
- References
- 0
- Language
- en
- Update notices
- erratum (2002-12-01)
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.