Colour Doppler energy (power) mode ultrasound
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Power Doppler is virtually angle independent, which allows better detection of low-flow velocities compared with colour Doppler.
“Power Doppler is also virtually angle independent which allows better detection of low-flow velocities compared with colour Doppler [58–60].”
From Volume and vascularity: Using ultrasound to unlock the secrets of the first trimester placenta (2019) · cites this paper as [58]
Cites
Power Doppler US: a potentially useful alternative to mean frequency-based color Doppler US.
Rubin, J. M., Bude, R. O., Carson, P. L., Bree, R. L., & Adler, R. S. (1994) · Radiology · doi:10.1148/radiology.190.3.8115639 · Cited by 864 · see citing works
Scattering of Ultrasound by Blood
Shung, K. K., Sigelmann, R. A., & Reid, J. M. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324604 · Cited by 309 · see citing works
Detection of soft-tissue hyperemia: value of power Doppler sonography.
Newman, J. S., Adler, R. S., Bude, R. O., & Rubin, J. M. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.2.8037037 · Cited by 308 · see citing works
Sahn, D. J. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)92621-6 · Cited by 296 · see citing works
Bude, R. O., Rubin, J. M., & Adler, R. S. (1994) · Radiology · doi:10.1148/radiology.192.3.8058946 · Cited by 251 · see citing works
Cowan, F. M., Pennock, J. M., Hanrahan, J., Manji, K. P., & Edwards, A. D. (1994) · Neuropediatrics · doi:10.1055/s-2008-1073018 · Cited by 212 · see citing works
Measurement of blood perfusion in tissue using doppler ultrasound
Dymling, S. O., Persson, H. W., & Hertz, C. H. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90179-z · Cited by 96 · see citing works
Fetal micrognathia: associated anomalies and outcome.
Bromley, B., & Benacerraf, B. R. (1994) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1994.13.7.529 · Cited by 92 · see citing works
Influence of various instrument settings on the flow information derived from the power mode
Jain, S. P., Fan, P. H., Philpot, E. F., Nanda, N. C., Aggarwal, K. K., Moos, S., & Yoganathan, A. P. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90008-k · Cited by 71 · see citing works
Winsberg, F. (1995) · Radiology · doi:10.1148/radiology.195.3.7754025 · Cited by 47 · see citing works
Color Doppler sonography in pyelonephritis
Eggli, K. D., & Eggli, D. F. (1992) · Pediatric Radiology · doi:10.1007/bf02013502 · Cited by 45 · see citing works
Evaluation of doppler ultrasound for blood perfusion measurements
Eriksson, R., Persson, H. W., Dymling, S. O., & Lindström, K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90180-5 · Cited by 37 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Hofbauer, L. C., & Heufelder, A. E. (2001) · Arthritis & Rheumatism · doi:10.1002/1529-0131(200102)44:2 · Cited by 100 · see citing works
Walther, M., Harms, H., Krenn, V., Radke, S., Kirschner, S., & Gohlke, F. (2002) · Radiology · doi:10.1148/radiol.2251011272 · Cited by 177 · see citing works
Bhal, P. S. (1999) · Human Reproduction · doi:10.1093/humrep/14.4.939 · Cited by 119 · see citing works
Power Doppler sonography: clinical applications
Martinoli, C., Pretolesi, F., Crespi, G., Bianchi, S., Gandolfo, N., Valle, M., & Derchi, L. E. (1998) · European Journal of Radiology · doi:10.1016/s0720-048x(98)00054-0 · Cited by 117 · see citing works
Pretorius, D. H., Nelson, T. R., Baergen, R. N., PAI, E. F., & Cantrell, C. J. (1998) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.1998.12010045.x · Cited by 108 · see citing works
Predictive factors for embryo implantation potential
Borini, A., Lagalla, C., Cattoli, M., Sereni, E., Sciajno, R., Flamigni, C., & Coticchio, G. (2005) · Reproductive BioMedicine Online · doi:10.1016/s1472-6483(10)61675-6 · Cited by 97 · see citing works
Myocardial Perfusion Imaging With Contrast Ultrasound
Porter, T. R., & Xie, F. (2010) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2009.09.024 · Cited by 96 · see citing works
Power Doppler sonography: general principles, clinical applications, and future prospects
Martinoli, C., Derchi, L. E., Rizzatto, G., & Solbiati, L. (1998) · European Radiology · doi:10.1007/s003300050540 · Cited by 95 · see citing works
Evaluation of solid breast lesions with power Doppler sonography
Kook, S., Park, H.-W., Lee, Y., Lee, Y.-U., Pae, W.-K., & Park, Y.-L. (1999) · Journal of Clinical Ultrasound · doi:10.1002/(sici)1097-0096(199906)27:5 · Cited by 85 · see citing works
Reproducibility of regional placental vascularity/perfusion measurement using 3D power Doppler
Lai, P., Wang, A. Y., & Welsh, A. W. (2010) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.7608 · Cited by 80 · see citing works
Broillet, A., Puginier, J., VENTRONE, R., & SCHNEIDER, M. (1998) · Investigative Radiology · doi:10.1097/00004424-199804000-00003 · Cited by 67 · see citing works
Bhal, P. S. (2001) · Human Reproduction · doi:10.1093/humrep/16.8.1682 · Cited by 65 · see citing works
High-resolution ultrasonic imaging of blood flow in the anterior segment of the eye.
Silverman, R. H., Kruse, D. E., Coleman, D. J., & Ferrara, K. W. (1999) · PubMed · Cited by 55 · see citing works
Collins, S. L., Stevenson, G. N., Noble, J. A., Impey, L., & Welsh, A. W. (2012) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.10122 · Cited by 52 · see citing works
The assessment of placental blood vessels by three-dimensional power Doppler ultrasound
Matijević, R., & Kurjak, A. (2002) · Journal of Perinatal Medicine · doi:10.1515/jpm.2002.004 · Cited by 51 · see citing works
Shrestha, S. M., Costello, M., Sjöblom, P., McNally, G., Bennett, M. J., Steigrad, S. J., & Hughes, G. J. (2006) · Journal of Assisted Reproduction and Genetics · doi:10.1007/s10815-006-9029-1 · Cited by 47 · see citing works
Color Doppler energy prediction of malignancy in adnexal masses using logistic regression models
Marret, H., Écochard, R., Giraudeau, B., Golfier, F., Raudrant, D., & Lansac, J. (2002) · Ultrasound in Obstetrics and Gynecology · doi:10.1046/j.1469-0705.2002.00853.x · Cited by 47 · see citing works
Quantification of power Doppler and the index 'fractional moving blood volume' (FMBV)
Welsh, A. (2004) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.1037 · Cited by 44 · see citing works
Power Doppler vascularity index for predicting malignancy of adnexal masses
Marret, H., Sauget, S., Giraudeau, B., Body, G., & Tranquart, F. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1893 · Cited by 40 · see citing works
Tailor, A., Jurkovic, D., BOURNE, T. H., NATUCCI, M., COLLINS, W. P., & Campbell, S. C. (1998) · Obstetrics and Gynecology · doi:10.1016/s0029-7844(98)00037-4 · Cited by 37 · see citing works
Costello, M., Shrestha, S. M., Sjöblom, P., McNally, G., Bennett, M. J., Steigrad, S. J., & Hughes, G. J. (2006) · Journal of Assisted Reproduction and Genetics · doi:10.1007/s10815-006-9067-8 · Cited by 35 · see citing works
Vlaisavljević, V., Reljič, M., Lovrec, V. G., Zazula, D., & Sergent, N. (2003) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.225 · Cited by 35 · see citing works
Suematsu, Y., Takamoto, S., & Ohtsuka, T. (2001) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2001.117625 · Cited by 35 · see citing works
Estimation of blood perfusion using ultrasound
Jansson, T. T., Persson, H. W., & Lindström, K. (1999) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411991534834 · Cited by 33 · see citing works
Volume and vascularity: Using ultrasound to unlock the secrets of the first trimester placenta
Mathewlynn, S., & Collins, S. L. (2019) · Placenta · doi:10.1016/j.placenta.2019.06.379 · Cited by 30 · see citing works
A review of the current status of breast ultrasound
Svensson, W. E. (1997) · European Journal of Ultrasound · doi:10.1016/s0929-8266(97)10009-x · Cited by 29 · see citing works
Welsh, A. W., Rubin, J. M., Fowlkes, J. B., & Fisk, N. M. (2005) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.1924 · Cited by 28 · see citing works
Review of Arterial Vascular Ultrasound
Phillips, G. W. L. (2000) · World Journal of Surgery · doi:10.1007/s002689910037 · Cited by 26 · see citing works
Power Doppler in breast tumours: a comparison with conventional colour doppler imaging
Wright, I. A., Pugh, N., Lyons, K., Webster, D. J. T., & Mansel, R. E. (1998) · European Journal of Ultrasound · doi:10.1016/s0929-8266(98)00040-8 · Cited by 25 · see citing works
Perifollicular vascularity monitoring and scoring: a clinical tool for selecting the best oocyte
Borini, A., Tallarini, A., Maccolini, A., Prato, L. D., & Flamigni, C. (2004) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2004.01.021 · Cited by 25 · see citing works
Development of three-dimensional power Doppler ultrasound imaging of fetoplacental vasculature
Welsh, A. W., Humphries, K. N., Cosgrove, D. O., Taylor, M. J. O., & Fisk, N. M. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00409-4 · Cited by 22 · see citing works
Self-citationAllard, L., Cloutier, G., Guo, Z., & Durand, L. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00130-6 · Cited by 21 · see citing works
Cloutier, G., Qin, Z., Garcia, D., Soulez, G., Oliva, V. L., & Durand, L. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00300-8 · Cited by 19 · see citing works
Power Doppler US: Evaluation of the Morphology of Stenoses with a Flow Phantom
Claudon, M., Winninger, D., Briançon, S., & Pesque, P. R. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja03109 · Cited by 19 · see citing works
Arruda, A. M., Dearani, J. A., Click, R. L., Ishikura, F., & Seward, J. B. (1999) · Journal of the American Society of Echocardiography · doi:10.1053/je.1999.v12.a99349 · Cited by 16 · see citing works
A High-Resolution 3D Ultrasonic System for Rapid Evaluation of the Anterior and Posterior Segment
Peyman, G. A., Ingram, C. P., Montilla, L. G., & Witte, R. S. (2012) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/15428877-20120105-01 · Cited by 15 · see citing works
Artificial Reproductive Technology Achievements for Optimizing Embryo Quality
Borini, A., Lagalla, C., Sciajno, R., Distratis, V., Bonu, M. A., Cattoli, M., & Coticchio, G. (2004) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1335.027 · Cited by 13 · see citing works
Peng, S. S., Lin, J.-H., Lee, W., Tsao, P., Shih, J., Liu, H., Li, Y.-W., Hsieh, F.-J., & Yau, K. T. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00047-2 · Cited by 13 · see citing works
Amplitude-coded color Doppler: clinical applications
Turetschek, K., Kollmann, C., Dorffner, R., Wunderbaldinger, P., & Mostbeck, G. (1999) · European Radiology · doi:10.1007/s003300050641 · Cited by 13 · see citing works
Marret, H., Vinatier, L., Sauget, S., Giraudeau, B., Body, G., & Tranquart, F. (2007) · Gynécologie Obstétrique & Fertilité · doi:10.1016/j.gyobfe.2007.04.009 · Cited by 11 · see citing works
Amplitude-coded colour Doppler sonography: physical principles and technique
Kollmann, C., Turetschek, K., & Mostbeck, G. (1998) · European Radiology · doi:10.1007/s003300050454 · Cited by 11 · see citing works
Shrestha, S. M., Costello, M., Sjöblom, P., McNally, G., Bennett, M. J., Steigrad, S. J., & Hughes, G. J. (2004) · Journal of Assisted Reproduction and Genetics · doi:10.1007/s10815-004-7526-7 · Cited by 10 · see citing works
A Brief Overview of Ophthalmic Ultrasound Imaging
Rosen, D. B., Conway, M. D., Ingram, C. P., Ross, R. D., & Montilla, L. G. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.83510 · Cited by 7 · see citing works
Yin, Y., Clark, A. R., & Collins, S. (2024) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2024.3376668 · Cited by 5 · see citing works
Novel Diagnostic Methods in Ophthalmology
Nowińska, A. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.79334 · Cited by 4 · see citing works
Doppler imaging in the diagnosis of ovarian disease
Haoula, Z., Deshpande, R., Jayaprakasan, K., & Raine‐Fenning, N. (2011) · Expert Opinion on Medical Diagnostics · doi:10.1517/17530059.2012.642366 · Cited by 4 · see citing works
Clough, G. R., Truscott, J. G., & Haigh, I. (2005) · Radiography · doi:10.1016/j.radi.2005.04.001 · Cited by 4 · see citing works
Bhal, N. (2001) · Journal of Obstetrics and Gynaecology · doi:10.1080/01443610120072108 · Cited by 4 · see citing works
Eising, E. G., Görges, R., Freudenberg, L., Kanja, J., & Bockisch, A. (2002) · Clinical Radiology · doi:10.1053/crad.2001.0903 · Cited by 4 · see citing works
Gregory, L. (2004) · Springer eBooks · doi:10.1007/978-1-4419-8955-0_3 · Cited by 4 · see citing works
3D Power Doppler Ultrasound Imaging of an in Vitro Arterial Stenosis
Allard, L., Cloutier, G., Fenster, A., & Durand, L. (1997) · Acoustical imaging · doi:10.1007/978-1-4419-8588-0_43 · Cited by 4 · see citing works
Tejada, J. G., Sánchez, V., Zamorano, J. L., Almerı́a, C., Rodrigo, J. L., Serra, V., & Sánchez‐Harguindey, L. (2000) · Revista Española de Cardiología · doi:10.1016/s0300-8932(00)75270-5 · Cited by 4 · see citing works
Clinical Application of Ultrasound in Infertility: From Two-dimensional to Three-dimensional
Chen, C., Wu, H., & Soong, Y. (2007) · Journal of Medical Ultrasound · doi:10.1016/s0929-6441(08)60030-2 · Cited by 3 · see citing works
Contrast Ultrasound Imaging: Methods, Analysis, and Applications
Porter, T. R., & Xie, F. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-3640-1.50007-1 · Cited by 3 · see citing works
Mathewlynn, S., Starck, L., Yin, Y., Soltaninejad, M., Swinburne, M., Nicolaides, K. H., Syngelaki, A., Contreras, A. G., Bigiotti, S., Woess, E. ‐., et al. (2026) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.70161 · Cited by 1 · see citing works
Morante, D. R. (2009) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) · Cited by 1 · see citing works
Cuevas, N. C. (2012) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Myocardial Contrast Stress Echocardiography
Porter, T. R., Venneri, L., & Xie, F. (2003) · Springer eBooks · doi:10.1007/978-3-662-05096-5_27
Review article Amplitude-coded color Doppler: clinical applications
Turetschek, K., Kollmann, C., Dorffner, R., Wunderbaldinger, P., & Mostbeck, G. (1999)
Review article Amplitude-coded colour Doppler sonography: physical principles and technique
Turetschek, K., & Mostbeck, G. (1998)
Svensson, W. E. (2006) · Ultrasound · doi:10.1179/174313406x82434
Jonsson, U. G. (2014) · KTH Publication Database DiVA (KTH Royal Institute of Technology)
Hsieh (2000) · doi:10.1002/(sici)1097-0096(200002)28:2
- Authors
- Macsweeney, J. E., Cosgrove, D. O., & Arenson, J.
- Affiliations
- Hammersmith Hospital (GB)
- Corresponding author
- Cosgrove, D.O.
- Venue
- Clinical Radiology
- Publisher
- Elsevier BV
- Published
- 1996-06
- Volume
- 51
- Issue
- 6
- Pages
- 387-390
- ISSN
- 0009-9260 (ISSN-L)
- OpenAlex
- W2010250556
- Cited by
- 63
- References
- 12
- Citations by year
- 2026: 1 · 2024: 1 · 2019: 3 · 2014: 1 · 2012: 2
- FWCI
- 7.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Clinical Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Ultrasound Imaging and Elastography
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Function and Risk Factors
- Keywords
- color Doppler ultrasound, power Doppler, blood flow imaging
- MeSH terms
- Blood Flow Velocity, Humans, Hyperemia, Ischemia, Regional Blood Flow, Sensitivity and Specificity, Ultrasonography, Doppler, Color
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review