Efficacy, bleeding patterns, and side effects of a 1-year contraceptive vaginal ring

The DOI matches its Crossref record; 10 of the 11 references it cites were found in a registry or an index.

Abstract

A combined contraceptive vaginal ring designed to last 12 months was tested at three clinic sites. This ring released approximately 1 mg of norethindrone acetate (NET-Ac) and 20 micrograms of ethinyl estradiol (EE) daily. A total of 60 women were enrolled to use the ring in a schedule of 3 weeks in/1 week out. Serum norethindrone (NET) and ethinyl estradiol (EE) levels were assayed twice weekly in cycles 6, 9, and 13. Mean NET concentrations between cycles 6 and 9 were relatively stable between 13 and 19 nmol/L but showed a 10%-21% decrease in all centers between cycles 9 and 13. Mean EE concentrations ranged from 75 to 103 pmol/L, but did not have the same decrease as NET between cycles 9 and 13. Cycles with progesterone peaks (> 9.6 nmol/L) compatible with some luteal activity occurred in 4% of cycles sampled in Sydney, 3% in Santo Domingo, and 26% in Los Angeles. Half of these cycles exhibited at least one progesterone value > 32 nmol/L with three of 18 occurring in noncompliant cycles. Heavier body weight was associated with increased probability of luteal activity. Based on serum estradiol peaks > 400 pmol/L, eight of 81 cycles appeared to have marked follicular activity with no luteal activity. No pregnancies occurred. Nausea was reported by about half the subjects in approximately 10% of the visits (mainly in the first 1-2 days in the first cycle immediately after ring insertion). Vomiting was reported by 20% of subjects early in the first cycle only. Headache was repo…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0010-7824(99)00035-9

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 10 references

Cited by

See all 43

Metadata

Authors
Weisberg, E., Fraser, I. S., Lacarra, M., Mishell, D. R., Alvarez, F., Brache, V, & Nash, H. A.
Affiliations
  • The University of Sydney (AU)
  • University of Southern California (US)
  • Profamilia (DO)
  • Population Council (US)
Corresponding author
Weisberg, Edith
Venue
Contraception
Publisher
Elsevier BV
Published
1999-05
Volume
59
Issue
5
Pages
311-318
ISSN
0010-7824 (ISSN-L)
OpenAlex
W2105085410
Cited by
43
References
11
Citations by year
2026: 2 · 2024: 1 · 2021: 2 · 2020: 2 · 2019: 3 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 3 · 2012: 1
FWCI
3.96
Type
journal article
Language
en
Open access
closed
Licence
www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Contraception (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Reproductive Health and Contraception
  • Health Sciences › Medicine › Psychiatry and Mental health › Sexual function and dysfunction studies
  • Social Sciences › Political Science and International Relations › International Human Rights and Reproductive Law
Keywords
contraceptive vaginal ring, norethindrone acetate, ethinyl estradiol, luteal activity, follicular activity, serum progesterone, serum estradiol, bleeding patterns, nausea, headache, vaginal discharge, serum lipids, body weight, contraceptive efficacy, adverse effects, non-compliance, contraception
MeSH terms
Norethindrone Acetate, Adolescent, Adult, Contraceptive Agents, Female, Contraceptive Devices, Female, Corpus Luteum, Ethinyl Estradiol, Female, Ovarian Follicle, Humans, Menstrual Cycle, Norethindrone, Ovary, Time Factors

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Efficacy, bleeding patterns, and side effects of a 1-year contraceptive vaginal ring. https://app.cochat.ai/papers/10.1016/s0010-7824(99)00035-9
The paper
Weisberg, E., Fraser, I. S., Lacarra, M., Mishell, D. R., Alvarez, F., Brache, V, & Nash, H. A. (1999). Efficacy, bleeding patterns, and side effects of a 1-year contraceptive vaginal ring. Contraception. https://doi.org/10.1016/s0010-7824(99)00035-9

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).