A normative study of the maintenance of wakefulness test (MWT)
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The maintenance of wakefulness test (MWT) is a daytime polysomnographic procedure which quantifies wake tendency by measuring the ability to remain awake during soporific circumstances. We present normative data based on 64 healthy subjects (27 males and 37 females) who adhered to uniform MWT procedural conditions including polysomnographic montage, illuminance level, seating position, room temperature, meal timing, and subject instructions. When allowed a maximum trial duration of 40 min, subjects' mean sleep latency to the first epoch of sustained sleep was 35.2 +/- 7.9 min. The lower normal limit, defined as two standard deviations below the mean, was 19.4 min. Calculation of data on the basis of a maximum trial duration of 20 min and sleep latency to the first appearance of brief sleep (a microsleep episode or one epoch of any stage of sleep) yielded a mean sleep latency of 18.1 +/- 3.6 min and a lower normal limit of 10.9 min. Sleep latency scores were significantly higher than those previously reported in patients with disorders of excessive somnolence. Therefore, the MWT appears to be a useful procedure in differentiating groups with normal daytime wake tendency from those with impaired wake tendency and in identifying individuals with pathologic inability to remain awake under soporific circumstances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,675
Guidelines for the Multiple Sleep Latency Test (MSLT): A Standard Measure of Sleepiness
Carskadon, M. A. (1986) · Sleep · doi:10.1093/sleep/9.4.519 · Cited by 1,603
Sleep in Normal Aging and Dementia
Bliwise, D. L. (1993) · Sleep · doi:10.1093/sleep/16.1.40 · Cited by 852
Sleepiness in Different Situations Measured by the Epworth Sleepiness Scale
Johns, M. W. (1994) · Sleep · doi:10.1093/sleep/17.8.703 · Cited by 734
Mitler, M. M., Gujavarty, K. S., & Browman, C. P. (1982) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(82)90142-0 · Cited by 522
Self-citationThe Clinical Use of the Multiple Sleep Latency Test
(1992) · Sleep · doi:10.1093/sleep/15.3.268 · Cited by 273
Daytime sleepiness: Quantification of a behavioral state
Carskadon, M. A., & Dement, W. C. (1987) · Neuroscience & Biobehavioral Reviews · doi:10.1016/s0149-7634(87)80016-7 · Cited by 172
Maintenance of Wakefulness Test and Multiple Sleep Latency Test
Sangal, R. B., Thomas, L., & Mitler, M. M. (1992) · Chest · doi:10.1378/chest.101.4.898 · Cited by 151
Self-citationMaintenance of Wakefulness Test in Obstructive Sleep Apnea Syndrome
Poceta, J. S., Timms, R. M., Jeong, D., Ho, S.-L., Erman, M. K., & Mitler, M. M. (1992) · CHEST Journal · doi:10.1378/chest.101.4.893 · Cited by 145
Self-citationMitler, M. M., Hajdukovic, R., Erman, M., & Koziol, J. A. (1990) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199001000-00008 · Cited by 99
Self-citationDisorders of Excessive Sleepiness
Sangal, R. B., Thomas, L., & Mitler, M. M. (1992) · CHEST Journal · doi:10.1378/chest.102.3.699 · Cited by 91
Self-citationPhysiological Sleep Tendency and Ability to Maintain Alertness at Night
Sugerman, J. L., & Walsh, J. K. (1989) · SLEEP · doi:10.1093/sleep/12.2.106 · Cited by 47
Treatment of Narcolepsy with Codeine
Fry, J. M., Pressman, M. R., DiPhillipo, M. A., & Forst-Paulus, M. (1986) · SLEEP · doi:10.1093/sleep/9.1.269 · Cited by 43
Browman, C. P., Gujavarty, K. S., Sampson, M. G., & Mitler, M. M. (1983) · SLEEP · doi:10.1093/sleep/6.1.23 · Cited by 40
Self-citationForty-Eight-Hour Polysomnographic Evaluation of Narcolepsy
Browman, C. P., Gujavarty, K. S., Yalles, S. F., & Mitler, M. M. (1986) · SLEEP · doi:10.1093/sleep/9.1.183 · Cited by 35
Self-citationSangal, R. B., & Sangal, J. M. (1997) · Clinical Electroencephalography · doi:10.1177/155005949702800311 · Cited by 29
Self-citationMultiple Sleep Latency Test (MSLT) and Sleep Apnea in Aged Women
Valencia‐Flores, M., Campos, R. M., Mendez, J. L., Haro, R., Schenkel, E., Bliwise, D. L., & Guilleminault, C. (1993) · SLEEP · doi:10.1093/sleep/16.2.114 · Cited by 20
Cited by
Littner, M. R., Kushida, C., Wise, M., G. Davila, D., Morgenthaler, T., Lee-Chiong, T., Hirshkowitz, M., Loube, D. L., Bailey, D., Berry, R. B., et al. (2005) · Sleep · doi:10.1093/sleep/28.1.113 · Cited by 1,142
Vigilance, alertness, or sustained attention: physiological basis and measurement
Oken, B. S., Salinsky, M. C., & Elsas, S. M. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2006.01.017 · Cited by 887
Jenkinson, C., Davies, R. J., Mullins, R., & Stradling, J. R. (1999) · The Lancet · doi:10.1016/s0140-6736(98)10532-9 · Cited by 826
Johns, M. W. (2000) · Journal of Sleep Research · doi:10.1046/j.1365-2869.2000.00177.x · Cited by 824
Distinguishing sleepiness and fatigue: focus on definition and measurement
Shen, J., Barbera, J., & Shapiro, C. M. (2006) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2005.05.004 · Cited by 687
Self-citation
Metadata
- Authors
- Doghramji, K., Mitler, M. M., Sangal, R. B., Shapiro, C., Taylor, S., Walsleben, J., Belisle, C., Erman, M. K., Hayduk, R., Hosn, R., B. O'Malley, E., Sangal, J. M., Schutte, S. L., & Youakim, J. M.
- Venue
- Electroencephalography and Clinical Neurophysiology
- Publisher
- Elsevier BV
- Published
- 1997-11
- Volume
- 103
- Issue
- 5
- Pages
- 554-562
- ISSN
- 0013-4694 (ISSN-L)
- OpenAlex
- W2111766101
- Cited by
- 331
- References
- 18
- FWCI
- 12.32
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.