The intramedullary skeletal kinetic distractor (ISKD): first clinical results of a new intramedullary nail for lengthening of the femur and tibia
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Problems, Obstacles, and Complications of Limb Lengthening by the Ilizarov Technique
PALEY, D. (1990) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199001000-00011 · Cited by 1,499 · cited 4×
“During lengthening there is a tendency for the limb segments to gradually deviate due to the imbalance of muscle forces on different sides of the bone [5].”
BackgroundInfluentialARONSON, J. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199708000-00019 · Cited by 326
A Fully Implantable Motorized Intramedullary Nail for Limb Lengthening and Bone Transport
Baumgart, R., Betz, A., & Schweiberer, L. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199710000-00023 · Cited by 227 · cited 1×
“[20] further reported 12 additional successful femoral lengthening cases with a similar device.”
BackgroundAnalysis of the External Fixator Pin-Bone Interface
Pettine, K. A., Chao, E. Y. S., & KELLY, P. J. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199308000-00004 · Cited by 101 · cited 1×
“Neurovascular structures are also vulnerable both at the time of screw or wire insertion as well as during distraction [3,4].”
BackgroundMaffulli, N., Lombari, C., Matarazzo, L., Nele, U., Pagnotta, G., & Fixsen, J. A. (1996) · PubMed · Cited by 87
Betz, A. K., Baumgart, R., & Schweiberer, L. (1990) · PubMed · Cited by 52
Cited by
Bone regeneration: current concepts and future directions
Dimitriou, R., Jones, E., McGonagle, D., & Giannoudis, P. V. (2011) · BMC Medicine · doi:10.1186/1741-7015-9-66 · Cited by 2,003
Masquelet technique for the treatment of bone defects: Tips-tricks and future directions
Giannoudis, P. V., Faour, O., Goff, T., Kanakaris, N., & Dimitriou, R. (2011) · Injury · doi:10.1016/j.injury.2011.03.036 · Cited by 414
PRECICE intramedullary limb lengthening system
Paley, D. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1005604 · Cited by 200
“The article by the ISKD’s designer (Cole) reviewed his initial series of 20 nails in 18 patients [34].”
BackgroundGlatt, V., Evans, C. H., & Tetsworth, K. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2016.00678 · Cited by 194
“…nail. various implants available use different strategies to provide the necessary distraction force, including mechanical, motorized, or magnetic devices (Betz et al., 1990; Baumgart et al., 1997; Cole et al., 2001; Thaller et al., 2014; Kucukkaya et al., 2015; Paley, 2015; Paley et al., 2015).”
MethodCurrent management of long bone large segmental defects
Lasanianos, N. G., Kanakaris, N. K., & Giannoudis, P. V. (2010) · Orthopaedics and Trauma · doi:10.1016/j.mporth.2009.10.003 · Cited by 167
Metadata
- Authors
- Cole, J. D., Justin, D., Kasparis, T., DeVlught, D., & Knobloch, C.
- Venue
- Injury
- Publisher
- Elsevier BV
- Published
- 2001-12
- Volume
- 32
- Pages
- 129-139
- ISSN
- 0020-1383 (ISSN-L)
- OpenAlex
- W2098571733
- Cited by
- 210
- References
- 6
- FWCI
- 0.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.