Effect of sampling time and air humidity on the bioefficiency of filter samplers for bioaerosol collection
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“with an average aerodynamic diameter reported to range from approximately 0.8-1.1 µm.(14,16,17)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [17]
Citations
Cites
Bioaerosols and occupational lung disease
Lacey, J., & Dutkiewicz, J. (1994) · Journal of Aerosol Science · doi:10.1016/0021-8502(94)90215-1 · Cited by 342
Collection of airborne micro‐organisms on Nuclepore filters, estimation and analysis—CAMNEA method
Palmgren, U., Ström, G., Blomquist, G., & Malmberg, P. (1986) · Journal of Applied Bacteriology · doi:10.1111/j.1365-2672.1986.tb04303.x · Cited by 259
Comparison of bioaerosol sampling methods in barns housing swine
Thorne, P. S., Kiekhaefer, M. S., Whitten, P., & Donham, K. J. (1992) · Applied and Environmental Microbiology · doi:10.1128/aem.58.8.2543-2551.1992 · Cited by 188
Eduarda, W., & Heederik, D. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010370 · Cited by 160
Health effects from work in swine confinement buildings
Donham, K. J. (1990) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700170105 · Cited by 129
Performance of Air-O-Cell, Burkard, and Button Samplers for Total Enumeration of Airborne Spores
Aizenberg, V., Reponen, T. A., Grinshpun, S. A., & Willeke, K. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984598 · Cited by 118
Self-citationPerformance Characteristics of the Button Personal Inhalable Aerosol Sampler
Aizenberg, V., Grinshpun, S. A., Willeke, K., Smith, J., & Baron, P. A. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984550 · Cited by 107
Self-citationHealth effects of organic dust exposure in dairy farmers
Malmberg, P. (1990) · American Journal of Industrial Medicine · doi:10.1002/ajim.4700170104 · Cited by 82
Techniques for Dispersion of Microorganisms into Air
Reponen, T., Willeke, K., Ulevicius, V., Grinshpun, S. A., & Donnelly, J. (1997) · Aerosol Science and Technology · doi:10.1080/02786829708965481 · Cited by 81 · cited 1×
“The "rst unit was an agar-tube disperser (Reponen et al., 1997) designed to release dry fungal spores.”
BackgroundSelf-citationPerformance of Air-O-Cell, Burkard, and Button Samplers for Total Enumeration of Airborne Spores
Aizenberg, V., Reponen, T. A., Grinshpun, S. A., & Willeke, K. (2000) · American Industrial Hygiene Association Journal · doi:10.1202/0002-8894(2000)061<0855:poaocb>2.0.co;2 · Cited by 72
Self-citation
Research works printed but not linked: 2
- American Conference of Governmental Industrial Hygienists (1995). Industrial ventilation (22nd ed.) (pp. 5–51). Cincinnati, OH: ACGIH.
- Willeke, K., & Macher, J. M. (1999). Air sampling. In: J.M. Macher (Ed.), Bioaerosols: Assessment and control (pp. 11-1–11-25) Cincinnati, OH: American Conference of Governmental Industrial Hygienists.
Cited by
Items 101–200 of 217
Molecular comparison of the sampling efficiency of four types of airborne bacterial samplers
Li, K. (2011) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2011.09.010 · Cited by 28
Han, T., Zhen, H., Fennell, D. E., & Mainelis, G. (2015) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.04.0206 · Cited by 24
Unterwurzacher, V., Pogner, C., Berger, H., Strauss, J., Strauss-Goller, S., & Gorfer, M. (2018) · Environmental Science Processes & Impacts · doi:10.1039/c8em00253c · Cited by 24
Docampo, S., Trigo, M. M., Recio, M., Melgar, M., García-Sánchez, J., Calderón-Ezquerro, M. D. C., & Cabezudo, B. (2009) · Aerobiologia · doi:10.1007/s10453-009-9146-2 · Cited by 24
“Many comparative studies between spore-sampling devices were found in the literature (Burge 1990; Li and Lin 1999; Morris et al. 2000; Wang et al. 2001; Spurgeon 2003; Wüst et al. 2003).”
BackgroundSampling and Analysis Using Filters
Raynor, P. C., Leith, D. E., Lee, K. W., & Mukund, R. (2011) · Wiley eBooks · doi:10.1002/9781118001684.ch7 · Cited by 24
Williams, A. P., Edwards‐Jones, G., & Jones, D. L. (2009) · Bioresource Technology · doi:10.1016/j.biortech.2009.03.018 · Cited by 23
“Another agar (R2A agar; Oxoid) was trialled as a way of estimating overall bacteria numbers, but proved to be unsuccessful as are many culturing techniques with bioaerosols (Amann et al., 1995; Wang et al., 2001).”
MethodJung, J. H., Lee, J. E., Hwang, G. B., Lee, B. U., Lee, S. B., Jurng, J., & Bae, G. N. (2009) · Analytical Chemistry · doi:10.1021/ac902189n · Cited by 22
King, M. D., & McFarland, A. R. (2012) · Aerosol Science and Technology · doi:10.1080/02786826.2012.669507 · Cited by 22
“A possible explanation for the lower concentration determined with the 47-mm filter is that the culturability of fragile organisms could have been affected by desiccation stresses resulting from continued passage of air over collected particles (Wang et al. 2001).”
BackgroundMadsen, A. M. (2003) · Aerobiologia · doi:10.1023/a:1024401523656 · Cited by 22
“actual number of spores due to aggregation of spores, inadequate staining of spores and loss of viability due to flow on the sampling filter (Eduard and Aalen, 1988; Heldal, Skogstad and Eduard, 1996; Wang et al., 2001) and the fact that not all fungi are cultureable.”
BackgroundFlash infrared radiation disinfection of fibrous filters contaminated with bioaerosols
Damit, B., Lee, C., & Wu, C.-Y. (2011) · Journal of Applied Microbiology · doi:10.1111/j.1365-2672.2011.04965.x · Cited by 23
“It must be noted that the viability of microorganisms collected on an air filter can decrease depending on relative humidity, loading time, and microbial species (Wang et al. 2001).”
BackgroundMethodInfluentialA New Field-Compatible Methodology for the Collection and Analysis of Fungal Fragments
Seo, S., Grinshpun, S. A., Iossifova, Y. Y., Schmechel, D., Rao, C. Y., & Reponen, T. A. (2007) · Aerosol Science and Technology · doi:10.1080/02786820701459940 · Cited by 24
“For this, particles collected onto the polycarbonate filter were suspended in two ml of sterile deionized water with 0.05% Tween 80 in a 10-ml sterile tube (Fisher Scientific, Pittsburgh, PA) by vortexing for two minutes followed by a 10-min ultrasonic bath agitation (Fisher Ultrasonic Cleaners, Model FS20, 3 qt., 120…”
MethodInfluentialSelf-citationCapture of bacterial bioaerosol with a wet electrostatic scrubber
Natale, F. D., Manna, L., Motta, F. L., Colicchio, R., Scaglione, E., Pagliuca, C., & Salvatore, P. (2018) · Journal of Electrostatics · doi:10.1016/j.elstat.2018.04.003 · Cited by 21
Viable fungi and bacteria in personal exposure samples in relation to microenvironments
Toivola, M., Alm, S., & Nevalainen, A. I. (2004) · Journal of Environmental Monitoring · doi:10.1039/b309960a · Cited by 21
Indoor air pollution control through ionization
Grinshpun, S. A., Adhikari, A., Lee, B. U., Trunov, M., Mainelis, G., Yermakov, M. V., & Reponen, T. A. (2004) · doi:10.2495/air040681 · Cited by 21
“9 μm for Bacillus subtilis [17], and 1.”
BackgroundSelf-citationDesign and development of a passive bioaerosol sampler using polarized ferroelectric polymer film
Therkorn, J., Myers, N. T., Calderon, L., Scheinbeim, J. I., & Mainelis, G. (2016) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2016.12.002 · Cited by 19
Design and evaluation of a new device for fungal spore aerosolization for laboratory applications
Scheermeyer, E., & Agranovski, I. E. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2009.06.003 · Cited by 18
Morisseau, K., Joubert, A., Coq, L. L., & Andrès, Y. (2016) · Indoor Air · doi:10.1111/ina.12330 · Cited by 21
Gashi, N., Szőke, Z., Fauszt, P., Dávid, P., Mikolás, M., Gal, F., Stündl, L., Remenyik, J., & Paholcsek, M. (2025) · Agronomy · doi:10.3390/agronomy15051003 · Cited by 22
“They allow for microbial analysis, especially when dilution of the sample is necessary, though their efficiency can decrease with prolonged sampling due to evaporation of the liquid medium, and they can be costly and require sterilization [203].”
Zand, E., Brockmann, G., Schottroff, F., Žunabović-Pichler, M., Hartmann, A., Kriegel, M., & Jaeger, H. (2022) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2022.111157 · Cited by 20
Comparison and evaluation of enumeration methods for measurement of fungal spore emission
Gopalakrishnan, S., Arigela, R., Thyagarajan, S., & Ravikrishna, R. (2022) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2022.106033 · Cited by 18
Chamber Evaluation of a Personal, Bioaerosol Cyclone Sampler
Macher, J. M., Chen, B. T., & Rao, C. Y. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802380351 · Cited by 18
“( 13 , 14 , 15 ) The fungi were grown on potato dextrose agar from spore suspensions in sterile distilled water that were spread evenly across the agar surface.”
MethodWang, H. X., Reponen, T. A., Adhikari, A., Willeke, K., & Grinshpun, S. A. (2004) · Aerosol Science and Technology · doi:10.1080/027868290891488 · Cited by 20
Self-citationLore, M. B., Sebastian, J. M., Brown, T. L., Viner, A. S., McCullough, N. V., & Hinrichs, S. H. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.640273 · Cited by 17
Indoor air sampling for detection of viral nucleic acids
Justen, L. J., Grimm, S. L., Esvelt, K. M., & Bradshaw, W. J. (2025) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2025.106549 · Cited by 19
Quantifying Airborne Dispersal Route of Corynespora cassiicola in Greenhouses
Zhao, Q. J., Shi, Y., Wang, Y., Xie, X., Li, L., Guo, L., Chai, A., & Li, B. (2021) · Frontiers in Microbiology · doi:10.3389/fmicb.2021.716758 · Cited by 18
Impact of culture media and sampling methods on Staphylococcus aureus aerosols
Chang, C., & Wang, L.-J. (2014) · Indoor Air · doi:10.1111/ina.12162 · Cited by 17
Sampling for Airborne Microorganisms
Grinshpun, S. A., Buttner, M. P., & Willeke, K. (2007) · Wiley eBooks · doi:10.1128/9781555815882.ch74 · Cited by 27
Self-citationZhong, C., & Xiong, X. (2021) · Progress in Organic Coatings · doi:10.1016/j.porgcoat.2021.106486 · Cited by 16
The Suitability of the IOM Foam Sampler for Bioaerosol Sampling in Occupational Environments
Haatainen, S., Laitinen, J., Linnainmaa, M., Reponen, T. A., & Kalliokoski, P. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903298015 · Cited by 16
“Even though the Andersen samples indicated that concentrations of bacteria were higher, bacteria were mainly gram-negative, which are more sensitive to desiccation stress caused by filter sampling than gram-positive or spore-forming bacteria.(13) On the other hand, both gram-positive and gram-negative bacteria survive…”
BackgroundSelf-citationHan, T., Thomas, N. M., & Mainelis, G. (2018) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2018.07.004 · Cited by 16
Occupational exposure to microorganisms used as biocontrol agents in plant production
Madsen, A. M. (2010) · Frontiers in Bioscience-Scholar · doi:10.2741/s174 · Cited by 15
An overview about varieties and detection methods of pathogenic microorganisms in indoor air
Li, X., Weng, Z., Aili, C., Liu, Q., & Sui, G. (2018) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/n972018-00328 · Cited by 16
Evaluation of the Bioaerosol Inactivation Ability of Chitosan-Coated Antimicrobial Filters
Hsu, Y.-F., Chuang, C.-Y., & Yang, S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18137183 · Cited by 14
“subtilis bioaerosols) as the testing aerosol to understand the efficiency with which aerosols penetrate the CCF filters according to previous studies [25,26].”
MethodPersonal Sampler for Viable Airborne Microorganisms: Main Development Stages
Agranovski, I. E. (2007) · CLEAN - Soil Air Water · doi:10.1002/clen.200600020 · Cited by 14
Agranovski, I. E., Pyankov, O. V., & Altman, I. S. (2005) · Aerosol Science and Technology · doi:10.1080/02786820500380230 · Cited by 14
“Particle counters (Model 1.108, Grimm Aerosol Technik, Ainring, Germany), which were previously used for real-time measurement of airborne bacteria (Wang et al. 2001; Agranovski et al. 2005), were employed for measurement of the particle concentration and size distribution of airborne…”
MethodInfluentialHan, T., Fennell, D. E., & Mainelis, G. (2015) · Aerosol Science and Technology · doi:10.1080/02786826.2015.1017040 · Cited by 13
“Here, particles collected on the filter were extracted into sterile DI water as described elsewhere (Wang et al. 2001).”
BackgroundMethodPrevalence, Dispersion and Nature of Bioaerosols over a Solid Landfill Site in Central India
Bhoyar, P. D., Kamdi, P., Bafana, A., Devara, P. C. S., Sivanesan, S., Kumar, A., & Krishnamurthi, K. (2023) · Aerosol and Air Quality Research · doi:10.4209/aaqr.220431 · Cited by 13
Simon, X., Bau, S., Boivin, A., Duquenne, P., Witschger, O., & Görner, P. (2016) · Aerosol Science and Technology · doi:10.1080/02786826.2016.1166173 · Cited by 13
“The collection into a liquid is a favorable aspect because it is considered to avoid the stress associated with desiccation of sampled microorganisms that occurs when samples are collected on filters (Jensen et al. 1992; Crook et al. 1997; Li et al. 1999; Wang et al. 2001).”
BackgroundInfluentialWalls, H. J., Kim, J., Yaga, R., Harvey, L. A., Haines, L. G., Ensor, D., Hering, S. V., Spielman, S., & Kreisberg, N. M. (2017) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1286290 · Cited by 13
“Several researchers showed that wet collection typically provides better viability maintenance (King and McFarland 2012; Li et al. 1999; Wang et al. 2001).”
Agarwal, S. (2017) · Environmental Science and Pollution Research · doi:10.1007/s11356-017-8705-2 · Cited by 14
Hsiao, P.-K., Cheng, C.-C., Chang, K., Yiin, .-M., Hsieh, C., & Tseng, C. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.865833 · Cited by 13
“However, the dehydration stress test only accounted for the stress caused by air flow, not for stress resulting from the impaction of bacterial particles onto the filter (Wang et al. 2001).”
BackgroundMethodInfluentialGupta, A. D., Srivastava, V., & Gupta, T. (2021) · Aerobiologia · doi:10.1007/s10453-021-09715-6 · Cited by 12
Jung, J. H., Lee, J. E., & Bae, G. N. (2011) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2011.05.005 · Cited by 12
Gaüzère, C., Moletta‐Denat, M., Bousta, F., Moularat, S., Orial, G., Ritoux, S., Godon, J., & Robine, E. (2012) · CLEAN - Soil Air Water · doi:10.1002/clen.201100699 · Cited by 12
Jeong, S. B., Heo, K. J., Ko, H. S., Ahn, J. P., Lee, S., & Jung, J. H. (2021) · Indoor Air · doi:10.1111/ina.12816 · Cited by 14
“…layer, defined as the ratio of the number of particles transferred from the filter to the extraction suspension to the number of particles removed from airflow using the filter. ξextraction for all filter layers was evaluated using the comparable method as >95%, as proposed by Wang et al (2001)18.”
MethodUnterwurzacher, V., Bruck, S., Biedermann, M., Pogner, C., Konlechner, A., Tondl, G., Berger, H., Pfeifer, C., Strauss, J., Gorfer, M., et al. (2021) · Aerosol Science and Engineering · doi:10.1007/s41810-021-00110-9 · Cited by 12
Han, T., Myers, N. T., Manibusan, S., & Mainelis, G. (2022) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2022.105951 · Cited by 12
Amato, P., Brisebois, E., Draghi, M., Duchaine, C., Fröhlich‐Nowoisky, J., Huffman, J. A., Mainelis, G., Robine, E., & Thibaudon, M. (2017) · Wiley eBooks · doi:10.1002/9781119132318.ch1b · Cited by 13
Electrochemical Detection of Airborne Influenza Virus using Air Sampling System
Kim, H., Min, J., Park, G., Shin, D., Sung, G., Kim, T., & Lee, M. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2018.06.0221 · Cited by 12
Aerosolization of fine particles increases due to microbial contamination of metalworking fluids
Wang, H. X., Reponen, T. A., Li, W., Martuzevičius, D., Grinshpun, S. A., & Willeke, K. (2004) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2004.11.007 · Cited by 11
Self-citationZhou, X.-Y., Liu, X., Zhao, H., Guo, G., Jiang, X., Liu, S., Sun, X., & Yang, H. (2024) · Microchimica Acta · doi:10.1007/s00604-024-06213-7 · Cited by 11
“The results showed that the bioefficiency of the samplers depended not only on the microbial species but also on the sampling time and RH [83].”
Unveiling the Role of Bioaerosols in Climate Processes: A Mini Review
Kumari, K., & Yadav, S. (2024) · International Journal of Environmental Research · doi:10.1007/s41742-024-00633-2 · Cited by 11
“Inevi-tably, sampling efficiency is dependent on time of sampling, temperature, relative humidity and microbial species (Wang et al. 2001).”
Miniaturizing Wet Scrubbers for Aerosolized Droplet Capture
Lee, U. N., van Neel, T. L., Lim, F. Y., Khor, J. W., He, J., Vaddi, R. S., Ong, A. Q. W., Tang, A., Berthier, J., Meschke, J. S., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01296 · Cited by 10
Biological Particles in the Indoor Environment
Colbeck, I., & Whitby, C. B. (2019) · Royal Society of Chemistry eBooks · doi:10.1039/9781788016179-00127 · Cited by 11
Grinshpun, S. A. (2010) · Wiley eBooks · doi:10.1002/9783527630134.ch13 · Cited by 12
Optimizing the Recovery of Surrogates for Bacterial Bioterrorism Agents from Ventilation Filters
Kim, S. W., Raynor, P. C., Kuehn, T. H., Goyal, S. M., Ramakrishnan, M. A., Anantharaman, S., & Farnsworth, J. E. (2008) · CLEAN - Soil Air Water · doi:10.1002/clen.200700182 · Cited by 10
The Optimization of Methods for the Collection of Aerosolized Murine Norovirus
Boles, C., Brown, G., Park, J. H., & Nonnenmann, M. W. (2020) · Food and Environmental Virology · doi:10.1007/s12560-020-09430-4 · Cited by 8
Methods of sampling airborne fungi in working environments of waste treatment facilities
Černá, K., Wittlingerová, Z., Zimová, M., & Janovský, Z. (2015) · International Journal of Occupational Medicine and Environmental Health · doi:10.13075/ijomeh.1896.00568 · Cited by 8
Evaluation of micro-well collector for capture and analysis of aerosolized Bacillus subtilis spores
He, J., Beck, N. K., Kossik, A. L., Zhang, J., Seto, E., Meschke, J. S., & Novosselov, I. V. (2018) · PLoS ONE · doi:10.1371/journal.pone.0197783 · Cited by 8
Bioanalysis within Microfluidics: A Review
Jing, W., & Sui, G. (2015) · ACS symposium series · doi:10.1021/bk-2015-1215.ch013 · Cited by 7
Evaluation of four sampling devices for Burkholderia pseudomallei laboratory aerosol studies
Schuit, M. A., Gardner, S., Taylor, J. R., & Dabisch, P. A. (2021) · PLoS neglected tropical diseases · doi:10.1371/journal.pntd.0009001 · Cited by 6
Reponen, T. A., Wang, H., & Grinshpun, S. A. (2005) · Journal of ASTM International · doi:10.1520/jai12838 · Cited by 6
Self-citationSalam, L. B. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96122-6.00003-7 · Cited by 8
Piri, A., Massoudifarid, M., & Hwang, J. (2024) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2024.135491 · Cited by 5
Nasrabadi, A. M., Han, J. S., Massoudifarid, M., Lee, S.-G., & Hwang, J. (2017) · Aerosol Science and Technology · doi:10.1080/02786826.2017.1350257 · Cited by 5
Xu, Z., Xu, H. T., & Yao, M. (2012) · Environmental Science and Pollution Research · doi:10.1007/s11356-012-1204-6 · Cited by 5
“Studies indicated that filter sampling could result in desiccation effects (Agranovski et al. 2004; Burton et al. 2005; Wang et al. 2001; Xu and Yao 2011).”
BackgroundPersonal exposure to microbial aerosols
Toivola, M. (2004) · STM:n Hallinnonalan avoin julkaisuarkisto (Julkari) · Cited by 5
Tseng, C., Yu, P.-Y., Liou, J.-W., & Chang, K. (2018) · Indoor Air · doi:10.1111/ina.12487 · Cited by 5
Chen, Y., Chen, J., Shankar, S. N., Amanatidis, S., Eiguren-Fernandez, A., Kreisberg, N. M., Spielman, S., Lednicky, J. A., & Wu, C. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2301941 · Cited by 5
“…desiccation, and cell damage of microorganisms from the prolonged sampling time can occur, thus affecting the viability of the microorganisms collected (Jensen et al. 1992; Durand et al. 2002; Uhrbrand, Schultz, and Madsen 2011; Stewart et al. 1995; Wang et al. 2001; Uhrbrand et al. 2017).”
BackgroundShin, S., Yoon, W., Lee, H. S., Jo, J. H., & Byeon, S. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-024-34749-x · Cited by 4
“In the case of filtration, drying of the collected particles due to long sampling times (Lundholm 1982; Jensen et al. 1992; Thorne et al. 1992; Wang et al. 2001) and sample loss during elution (Dabisch et al. 2012) can occur, which is especially noticeable in fibrous filters (Adams et al. 2015).”
Zhang, S., Li, S., Xu, Y., Du, Y., Wang, A., Liu, Z., & Yan, K. (2023) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2023.138790 · Cited by 4
Lee, J. (2009) · Cited by 4
Measuring airborne microorganisms and dust from livestock houses
Zhao, Y. (2011) · doi:10.18174/165388 · Cited by 8
León, I. M., Auvermann, B. W., Bush, K. J., Casey, K. D., Pinchak, W. E., Levent, G., Vinasco, J., Lawhon, S. D., Smith, J. K., Scott, H. M., et al. (2025) · Applied Microbiology · doi:10.3390/applmicrobiol5030063 · Cited by 3
Purification de l'air ambiant par l'action bactéricide de la photocatalyse
Faure, M. J. (2010) · theses.fr (ABES) · doi:10.70675/f15b6d82zb2f5z4c2fz95b7z4479346084d8 · Cited by 3
Lee, S.-A., Low, Y.-L., Adhikari, A., Wang, W.-K., Liang, C., Chang, L.-T., & Tsai, C. (2025) · Aerosol and Air Quality Research · doi:10.1007/s44408-025-00021-1 · Cited by 2
Mutalik, C., & Roy, C. J. (2026) · Talanta · doi:10.1016/j.talanta.2026.129409 · Cited by 4
Model of Staphylococcus aureus Growth and Reproduction on the Surface of Activated Carbon
Zhang, G., Yan, X., Liu, S., Chen, C., & Wang, Y. (2025) · Buildings · doi:10.3390/buildings15060874 · Cited by 2
Indoor and Outdoor Air Sampling
Omberg, K. M., & Stetzenbach, L. D. (2014) · ASM Press eBooks · doi:10.1128/9781555817473.ch6 · Cited by 2
Chatterjee, K., & Sigler, V. (2014) · Aerobiologia · doi:10.1007/s10453-014-9343-5 · Cited by 2
“…membrane overlay while limiting growth, suggesting that the modifications could be utilized to overcome the previously reported desiccation limitations associated with extended impaction times or multiple, short samplings that occur throughout en extended period (Wang et al. 2001; Xu et al. 2013a).”
BackgroundAnalysis on agarwood vapour using headspace volatile DVB-CAR-PDMS SPME with different sampling time
Ismail, N., Rahiman, M. H. F., Taib, M. N., Ibrahim, M., Zareen, S., & Tajuddin, S. N. (2016) · IEEE Control and System Graduate Research Colloquium (ICSGRC) · doi:10.1109/icsgrc.2016.7813322 · Cited by 2
“This finding supports previous by other researcher [5, 13].”
ResultGrinshpun, S. A., Weber, A. M., Yermakov, M. V., Indugula, R., Elmashae, Y., Reponen, T. A., & Rose, L. J. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1304645 · Cited by 2
“We recognize that two extractions may not remove 100% of the spores; however, it was found[22] with epifluorescent microscopy that only 2–4% of microorganisms remained on a polycarbonate filter after a single extraction.”
InfluentialSelf-citationClimate Change and Bioaerosols: Impacts on Airborne Microbial Distribution and Public Health
Sharmi, K. R., Poorniammal, R., Prabhu, S., Karthikeyan, S., Vaishnav, K. S., & Jeyasurya, T. (2026) · Aerobiology · doi:10.3390/aerobiology4030016 · Cited by 2
Investigation of bioaerosol characterization bias due to aerosolization and sampling
Zhen, H. (2015) · doi:10.7282/t3s75j6v · Cited by 1
Sampling of Microbiological Samples
Stam, C., Behar, A., & Cooper, M. (2016) · Springer protocols handbooks/Springer protocols · doi:10.1007/978-1-4939-3185-9_3 · Cited by 1
Miettinen, H. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100155-4.00045-5 · Cited by 1
Sampling methods for airborne microorganisms
Mohammed, S. S. D., & Balogu, T. V. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-96122-6.00001-3 · Cited by 5
Microbial aerosols: analytical methods, dispersal mechanisms and health risk assessment
Gautam, S., Setu, S., Khan, M. N. H., Khan, M. G. Q., & Khan, M. B. (2023) · Elsevier eBooks · doi:10.1016/b978-0-443-15319-8.00003-4 · Cited by 1
Hou, Y., Xie, J., Jin, L. N., You, R., & Li, X. D. (2025) · ACS ES&T Air · doi:10.1021/acsestair.5c00285 · Cited by 1
Miettinen, H. (2005) · Elsevier eBooks · doi:10.1533/9781845690533.3.619 · Cited by 1
Tracking the fate of biocontrol microorganisms in the environment using intrinsic SCAR markers
Holmberg, A.-I. J. (2011) · Epsilon Open Archive (Sveriges lantbruksuniversitet biblioteket (Swedish University of Agricultural Sciences)) · Cited by 1
Lancereau, Q. (2012) · theses.fr (ABES) · doi:10.70675/ee88b021z25a5z425aza520z711a6f756e6f · Cited by 1
Zhao, Y., Aarnink, A. J. A., & Dijkman, R. (2012)
Development and application of quantitative bioaerosol analysis method using PCR
An, H. R. (2009) · Rutgers University Community Repository (Rutgers University) · doi:10.7282/t3251jdt · Cited by 1
Characterization of bacterial processes in the subsurface and the atmosphere
Son, E.-K. (2009) · Rutgers University Community Repository (Rutgers University) · doi:10.7282/t34q7v4c
“common soil bacteria, which has been widely studied for a variety of purposes and which is often used as a model microorganism in aerobiological studies (An et al., 2004; Wang et al., 2001; Yao et al., 2005).”
BackgroundThe Effect of Recovery on Modeling Inactivation of Bacillus Spores on HVAC Filters
Murali, B., & Mitchell, J. (2014) · ScholarsArchive (Brigham Young University)
Effect of Environmental Parameters on the Biocidal Performance of Iodine-Treated Filters
Wu, C., Lee, J., Reiemenschneider, L., & Theodore, A. (2008) · Defense Technical Information Center (DTIC)
Pellerin, G. (2017) · theses.fr (ABES) · doi:10.70675/a022dcb0z82ddz4ad0z82dazdefb534de2fa · Cited by 3
“Les spores bactériennes et fongiques présentent un taux de survie plus important que les bactéries végétatives (Jensen et al., 1992; Palmgren et al., 1986; Wang et al., 2001).”
Impact of Passive Air Treatment on Microbial Contamination in a Controlled Chamber Environment
Troup, D. J. (2017) · UA Campus Repository (The University of Arizona)
New Methods of Controlling Biological Aerosols
Huang, S. (2010) · Griffith Research Online · doi:10.25904/1912/605
Metadata
- Authors
- Wang, Z., Reponen, T., A. Grinshpun, S., L. Górny, R., & Willeke, K.
- Affiliations
- University of Cincinnati (US)
- Corresponding author
- Reponen, Tiina
- Venue
- Journal of Aerosol Science
- Publisher
- Elsevier BV
- Published
- 2001-05
- Volume
- 32
- Issue
- 5
- Pages
- 661-674
- ISSN
- 0021-8502 (ISSN-L)
- OpenAlex
- W2161558350
- Semantic Scholar
- 7151ee46ff3594338e85f05711a3391ed2996d72
- Cited by
- 213
- References
- 19
- Citations by year
- 2026: 3 · 2025: 10 · 2024: 10 · 2023: 9 · 2022: 6 · 2021: 10 · 2020: 4 · 2019: 6 · 2018: 13 · 2017: 10 · 2016: 8 · 2015: 10 · 2014: 7 · 2013: 4 · 2012: 11
- FWCI
- 4.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Aerosol Science (publishedVersion)
- Funders
- University of Cincinnati
- National Institute for Occupational Safety and Health
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- bioaerosol sampling, sampling time, relative humidity, biological efficiency, fungal spores, endospores, culturability, Penicillium melinii, Aspergillus versicolor, Bacillus subtilis, Pseudomonas fluorescens, Serratia marcescens, polycarbonate filters
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.