The DOI matches its Crossref record.
The rate of oxygen uptake by human red blood cells.
Open accessAbstract
Oxygen uptake into intact and reconstituted human red blood cells was measured using dual wavelength, stopped flow techniques. The rate of oxygen uptake by human erythrocytes is roughly 40 times slower (t 1/2 congruent to 80 ms at 0.125 mM O2, 25 degrees C) than the corresponding rate of oxygen combination with free hemoglobin. Oxygen transport through the red cell cytoplasm accounts for part of this difference and predicts a half-time of uptake of about 15 ms, which is still 5 times smaller than that observed experimentally. Further limitation of uptake appears to be due to the presence of unstirred layers of solvent adjacent to the red cell surface. Very rapidly after mixing, these layers form and become depleted of O2 due to uptake by the cells. This requires that the bulk of the oxygen molecules must diffuse over rather large distances, 1.0 to 5.0 micrometer, before they can penetrate the erythrocytes. A mathematical model was developed to take into account diffusion through an unstirred solvent layer which increases in thickness with time. This scheme can account quantitatively both for the dependence of the apparent rate of uptake on O2 concentration and for the shape of the observed time courses. In addition, the diffusion parameters which were developed for the O2 reaction can also be used to describe quantitatively the rates and time courses of CO and ethyl isocyanide uptake and the rates and time courses of O2 release from cells in the presence of sodium dithionite. Finally, the parameters used to describe the stopped flow results can also be used to simulate quantitatively O2 uptake time courses obtained from previous studies with thin films of red cells (Sinha, A. K. (1969) Ph.D. dissertation, University of California, San Francisco; Thews, G. (1959) Arch. Gesamte Physiol. Mens. Tiere (Pflufgers) 268, 308-317).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rother, R. P., Bell, L., Hillmen, P., & Gladwin, M. T. (2005) · JAMA · doi:10.1001/jama.293.13.1653 · Cited by 1,557
Cell-free hemoglobin limits nitric oxide bioavailability in sickle-cell disease
Reiter, C. D., Wang, X., Tanus-Santos, J. E., Hogg, N., Cannon, R. O., Schechter, A. N., & Gladwin, M. T. (2002) · Nature Medicine · doi:10.1038/nm1202-799 · Cited by 1,330
Donadee, C., Raat, N. J. H., Kanias, T., Tejero, J., Lee, J. S., Kelley, E. E., Zhao, X., Liu, C., Reynolds, H., Azarov, I., et al. (2011) · Circulation · doi:10.1161/circulationaha.110.008698 · Cited by 572
Diffusion-limited reaction of free nitric oxide with erythrocytes
Liu, X., Miller, M. J. S., Joshi, M. S., Sadowska-Krowicka, H., Clark, D. A., & Lancaster, J. R. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.30.18709 · Cited by 512
Wittenberg, B. A., & Wittenberg, J. B. (1989) · Annual Review of Physiology · doi:10.1146/annurev.ph.51.030189.004233 · Cited by 471
Metadata
- Authors
- Coin, J. T., & Olson, J. S.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1979-02
- Volume
- 254
- Issue
- 4
- Pages
- 1178-1190
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1584104642
- Cited by
- 199
- References
- 0
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The rate of oxygen uptake by human red blood cells. https://app.cochat.ai/papers/10.1016/s0021-9258(17)34185-6
- The paper
- Coin, J. T., & Olson, J. S. (1979). The rate of oxygen uptake by human red blood cells. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(17)34185-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.