ANALYZER FOR ACCURATE ESTIMATION OF RESPIRATORY GASES IN ONE-HALF CUBIC CENTIMETER SAMPLES
Open accessAbstract
The present analyzer permits the determination of carbon dioxide, oxygen, and nitrogen in 0.5 cc. or less of respiratory gases with an accuracy of +0.015 volume per cent. It will handle directly samples containing from zero to over 99 per cent absorbable gases. The analysis requires 6 to 8 minutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Anaerobic threshold and respiratory gas exchange during exercise.
Wasserman, K., Whipp, B. J., Koyl, S. N., & Beaver, W. L. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.35.2.236 · Cited by 2,094
Validity of four motion sensors in measuring moderate intensity physical activity
BASSETT, D. R. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00006 · Cited by 527
THE PHYSIOLOGICAL MEANING OF THE MAXIMAL OXYGEN INTAKE TEST1
Mitchell, J. H., Sproule, B. J., & Chapman, C. B. (1958) · Journal of Clinical Investigation · doi:10.1172/jci103636 · Cited by 516
Phinney, S. D., Bistrian, B. R., Evans, W. J., Gervino, E., & Blackburn, G. L. (1983) · Metabolism · doi:10.1016/0026-0495(83)90106-3 · Cited by 422
The Influence of Increasing Ventilatory Effort on Arousal from Sleep
Gleeson, K., Zwillich, C. W., & White, D. P. (1990) · American Review of Respiratory Disease · doi:10.1164/ajrccm/142.2.295 · Cited by 411
Metadata
- Authors
- Scholander, P. F.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1947-01
- Volume
- 167
- Issue
- 1
- Pages
- 235-250
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W138127152
- Cited by
- 1,025
- References
- 0
- FWCI
- 21.48
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ANALYZER FOR ACCURATE ESTIMATION OF RESPIRATORY GASES IN ONE-HALF CUBIC CENTIMETER SAMPLES. https://app.cochat.ai/papers/10.1016/s0021-9258(17)35161-x
- The paper
- Scholander, P. F. (1947). ANALYZER FOR ACCURATE ESTIMATION OF RESPIRATORY GASES IN ONE-HALF CUBIC CENTIMETER SAMPLES. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(17)35161-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.