Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 161

The DOI matches its Crossref record.

The lysosomal proton pump is electrogenic.

Open access
Harikumar, P, Reeves, J P·1983·Journal of Biological Chemistry

Abstract

Lysosomes were purified approximately 40-fold from rat kidney cortex by differential and Percoll density gradient centrifugation. In a sucrose medium, the lysosomes quenched the fluorescence of the potential sensitive dye diS-C3-(5) (3,3'-dipropylthiocarbo-cyanine iodide) in a time-dependent manner, indicating that the dye accumulates within the lysosomal interior. After treatment of the lysosomes with valinomycin, the dye fluorescence displayed a logarithmic dependence upon the external K+ concentration; thus, the fluorescence signal provides a semiquantitative measure of the lysosomal membrane potential (delta psi). In the absence of valinomycin, lysosomal quenching of diS-C3-(5) fluorescence was partially reversed by agents which collapse the lysosomal pH gradient (ammonium sulfate, chloroquine, and K nigericin), suggesting that the proton gradient across the lysosomal membrane contributes to delta psi. A rapid increase in diS-C3-(5) fluorescence, indicative of an increase in delta psi, was observed upon the addition of Mg-ATP to the lysosomes. The ATP-dependent fluorescence change was inhibited by protonophores, K valinomycin, permeable anions, and N-ethylmaleimide, but was unaffected by ammonium sulfate, K nigericin, or sodium vanadate. Oligomycin had no effect at concentrations below 2 micrograms/ml; at higher concentrations, oligomycin partially inhibited the fluorescence response to Mg-ATP, but it also inhibited the fluorescence response to K valinomycin, suggesting that it had modified the permeability of the lysosomal membrane. Dicylohexylcarbodiimide behaved similarly to oligomycin. Mg-ATP also altered the lysosomal distribution of 86Rb+ (in the presence of valinomycin) and S[14C]CN-, consistent with an increase in the potential of the lysosomal interior of 40-50 mV. The results demonstrate that the lysosomal proton pump is electrogenic.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(17)44471-1

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 161

Metadata

Authors
Harikumar, P., & Reeves, J. P.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1983-09
Volume
258
Issue
17
Pages
10403-10410
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1590346152
Cited by
161
References
0
FWCI
5.06
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The lysosomal proton pump is electrogenic. https://app.cochat.ai/papers/10.1016/s0021-9258(17)44471-1
The paper
Harikumar, P., & Reeves, J. P. (1983). The lysosomal proton pump is electrogenic. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(17)44471-1

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.