Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 387

The DOI matches its Crossref record.

The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration.

Open access
Wilson, D F, Rumsey, W L, Green, T J, Vanderkooi, J M·1988·Journal of Biological Chemistry

Abstract

Oxygen-dependent quenching of phosphorescence has been used to measure the dependence of mitochondrial oxidative phosphorylation on oxygen concentration in suspensions of isolated rat liver mitochondria. An instrument has been designed which simultaneously monitors the phosphorescence lifetime of a fluorophor and the reduction of cytochrome c by dual wavelength spectrophotometry. The phosphorescence lifetime method gives very rapid (less than 100 ms) measure of the oxygen concentration (Vanderkooi, J. M., Maniara, G., Green, T. J., and Wilson, D. F. (1987) J. Biol. Chem. 262, 5476-5482) from concentrations characteristic of air-saturated media to as low as 2 x 10(-8) M. The results may be summarized as follows. For well coupled rat liver mitochondria at pH 7.0 and in the presence of ATP, as the oxygen concentration was lowered, increased cytochrome c reduction was observed to begin at oxygen concentrations greater than 20 microM. For mitochondria in the presence of uncoupler, cytochrome c reduction began at oxygen concentrations less than 1.0 microM. The oxygen dependence of reduction of cytochrome c in well coupled mitochondria treated with ATP was strongly dependent on the pH of the suspending medium. Reduction of cytochrome c began at higher oxygen concentrations as the pH was made more alkaline. The oxygen concentration for half-maximal respiratory rates was much larger for well coupled mitochondria treated with ATP (approximately 0.7 microM) than for mitochondria treated with uncoupler (less than 0.1 microM). It is concluded that the oxygen dependence of mitochondrial oxidative phosphorylation is such that mitochondria could function in their proposed role of tissue oxygen sensors for regulation of such diverse functions as local blood flow and electrical activity in the carotid body.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(18)69126-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 387

Metadata

Authors
Wilson, D. F., Rumsey, W. L., Green, T. J., & Vanderkooi, J. M.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1988-02
Volume
263
Issue
6
Pages
2712-2718
ISSN
0021-9258 (ISSN-L)
OpenAlex
W1562098826
Cited by
387
References
0
FWCI
2.54
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration. https://app.cochat.ai/papers/10.1016/s0021-9258(18)69126-4
The paper
Wilson, D. F., Rumsey, W. L., Green, T. J., & Vanderkooi, J. M. (1988). The oxygen dependence of mitochondrial oxidative phosphorylation measured by a new optical method for measuring oxygen concentration. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(18)69126-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.