The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Radioimmunoassay for Cyclic Nucleotides
Open accessAbstract
Abstract Sensitive and specific radioimmunoassays have been developed for cyclic adenosine 3',5'-monophosphate (cAMP), cyclic guanosine 3',5'-monophosphate (cGMP), cyclic inosine 3',5'-monophosphate (cIMP), and cyclic uridine 3',5'-monophosphate (cUMP). These assays are based upon competition of the cyclic nucleotide with isotopically labeled cyclic nucleotide derivatives for binding sites on specific antibody. Antibodies to the cyclic nucleotides were obtained by immunizing rabbits with an antigen prepared by conjugating the 2'-O-succinyl derivative of the cyclic nucleotide with protein (human serum albumin or keyhole limpet hemocyanin). High specific activity derivatives of the cyclic nucleotides (g150 Ci per mmole) were prepared by iodinating (125I) the tyrosine methyl ester derivative of the succinylated cyclic nucleotide. Free and bound 125I-labeled cyclic nucleotides were separated by either the second antibody precipitation technique or (NH4)2SO4 fractionation. Binding equilibrium was reached in 24 hours, but sensitive and reproducible assays were obtained after 4 to 6 hours of incubation. The sensitivity and assay range for the various radioimmunoassays are (picomoles per tube): cAMP, 0.01 to 2; cGMP, 0.01 to 1.0; cIMP, 0.12 to 10.0; and cUMP, 0.1 to 10.0. Structurally related purine and pyrimidine nucleotides and nucleosides exhibited ≤0.005% competitive binding in all immunoassays except cIMP which showed 0.35% competitive binding in the cGMP assay, cGMP 1% in the cIMP assay, and cIMP 1% in the cUMP assay.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Immunoassay of endogenous plasma insulin in man
Yalow, R. S., & Berson, S. A. (1960) · Journal of Clinical Investigation · doi:10.1172/jci104130 · Cited by 3,041
Cited by
Arnold, W. P., Mittal, C. K., Katsuki, S., & Murad, F. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.8.3203 · Cited by 1,455
Agonist-induced endothelium-dependent relaxation in rat thoracic aorta may be mediated through cGMP
Rapoport, R. M., & Murad, F. (1983) · Circulation Research · doi:10.1161/01.res.52.3.352 · Cited by 928
Establishment and Characterization of Two Distinct Mouse Testicular Epithelial Cell Line
Matfier, J. P. (1980) · Biology of Reproduction · doi:10.1095/biolreprod23.1.243 · Cited by 396
Sprecher, H., VanRollins, M., Sun, F., Wyche, A., & Needleman, P. (1982) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)34869-5 · Cited by 76
Bhushan, S., Kondo, K., Polhemus, D. J., Otsuka, H., Nicholson, C. K., Tao, Y.-X., Huang, H., Georgiopoulou, V. V., Murohara, T., Calvert, J. W., et al. (2014) · Circulation Research · doi:10.1161/circresaha.114.301475 · Cited by 69
Metadata
- Authors
- Steiner, A. L., Parker, C. W., & Kipnis, D. M.
- Venue
- Journal of Biological Chemistry
- Publisher
- Elsevier BV
- Published
- 1972-02
- Volume
- 247
- Issue
- 4
- Pages
- 1106-1113
- ISSN
- 0021-9258 (ISSN-L)
- OpenAlex
- W1518913349
- Cited by
- 2,026
- References
- 1
- FWCI
- 24.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Radioimmunoassay for Cyclic Nucleotides. https://app.cochat.ai/papers/10.1016/s0021-9258(19)45621-4
- The paper
- Steiner, A. L., Parker, C. W., & Kipnis, D. M. (1972). Radioimmunoassay for Cyclic Nucleotides. Journal of Biological Chemistry. https://doi.org/10.1016/s0021-9258(19)45621-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.