Kinetic parameters of the lipoprotein transport systems in the adrenal gland of the rat determined in vivo. Comparison of low and high density lipoproteins of human and rat origin.

Andersen, J.M., Dietschy, J.M.·1981·Journal of Biological Chemistry

Abstract

These studies were done to characterize the rate of uptake of high (HDL) and low (LDL) density lipoprotein cholesterol by the adrenal gland of the rat under in vivo conditions. Animals were pretreated for 4 days with 4-aminopyrazolo[3,4-d]pyrimidine to essentially eliminate endogenous plasma lipoproteins and with aminoglutethimide for 1 h to block conversion of cholesterol to adrenal hormones. Such animals were then infused with varying amounts of HDL and LDL from both human and rat plasma, and this led to rapid accumulation of cholesterol, both free and esterified, in the adrenal glands over the subsequent 4-h period of observation. This uptake process was linear with respect to time and manifested saturation kinetics with respect to the steady state level of plasma lipoprotein cholesterol. When human lipoproteins were infused, the maximal rate of cholesterol uptake was approximately 0.45 mg/pair of adrenal glands/h for both HDL and LDL; however, the half-maximal rate of uptake (Km) was achieved at a plasma HDL cholesterol concentration of only 12 mg/dl while a concentration of 61 mg/dl was required to achieve the same velocity with LDL. When similar experiments were carried out with rat HDL, the Km equaled 7.2 mg/dl and a maximal rate of uptake of 0.32 mg/pair of adrenal glands/h was achieved. It was not possible to obtain complete kinetic curves using rat LDL, but at physiological plasma concentrations, there was no difference in the rate of cholesterol uptake from LDL of…

Overview

Integrity signals

Registry

Crossref · 10.1016/s0021-9258(19)68971-4

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Mice and other rodents have very low levels of LDL and use HDL to deliver cholesterol to the adrenal, whereas in humans and other species LDL is the predominant cholesterol-carrying lipoprotein.

    “Mice and other rodents have very low levels of LDL and use HDL to deliver cholesterol to the adrenal (31, 32); however, in other species, including humans, LDL is the predominant cholesterol-carrying lipoprotein.”

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 31

  1. Srere, 1948, J. Biol. Chem., 176, 829, 10.1016/S0021-9258(19)52697-7 · DOI
  2. Morris, 1959, J. Biol. Chem., 234, 1095, 10.1016/S0021-9258(18)98137-8 · DOI
  3. Borokowski, 1972, J. Clin. Invest., 51, 1664, 10.1172/JCI106968 · DOI
  4. Turley, 1980, J. Lipid Res.
  5. Dexter, 1970, Endocrinology, 87, 836, 10.1210/endo-87-5-836 · DOI
  6. Andersen, 1976, Biochem. Biophys. Res. Common., 72, 880, 10.1016/S0006-291X(76)80214-8 · DOI
  7. Andersen, 1977, J. Biol. Chem., 252, 3646, 10.1016/S0021-9258(17)40301-2 · DOI
  8. Andersen, 1979, J. Lipid Res., 20, 740, 10.1016/S0022-2275(20)40027-6 · DOI
  9. Andersen, 1976, Science, 193, 903, 10.1126/science.948751 · DOI
  10. Balasubramaniam, 1977, J. Biol. Chem., 252, 1771, 10.1016/S0021-9258(17)40617-X · DOI
  11. Andersen, 1977, J. Biol. Chem., 252, 3652, 10.1016/S0021-9258(17)40302-4 · DOI
  12. Balasubramaniam, 1977, Proc. Natl. Acad. Sci. U. S. A., 74, 1421, 10.1073/pnas.74.4.1421 · DOI
  13. Porter, 1965, Am. J. Physiol., 209, 811, 10.1152/ajplegacy.1965.209.4.811 · DOI
  14. Andersen, 1978, J. Biol. Chem., 253, 9024, 10.1016/S0021-9258(17)34280-1 · DOI
  15. Gwynne, 1976, Proc. Natl. Acad. Sci. U. S. A., 73, 4329, 10.1073/pnas.73.12.4329 · DOI
  16. Gwynne, 1978, Metabolism, 27, 1593, 10.1016/0026-0495(78)90281-0 · DOI
  17. Noble, 1968, J. Lipid Res., 9, 693, 10.1016/S0022-2275(20)42680-X · DOI
  18. Weber, 1969, J. Biol. Chem., 244, 4406, 10.1016/S0021-9258(18)94333-4 · DOI
  19. Innerarity, 1980, J. Biol. Chem., 255, 11163, 10.1016/S0021-9258(19)70270-1 · DOI
  20. Brown, 1979, Hormone Res., 35, 215
  21. Dexter, 1967, J. Clin. Endocrinol., 27, 473, 10.1210/jcem-27-4-473 · DOI
  22. Lasser, 1973, J. Lipid Res., 14, 1, 10.1016/S0022-2275(20)39322-6 · DOI
  23. Thomson, 1977, J. Theor. Biol., 64, 277, 10.1016/0022-5193(77)90357-5 · DOI
  24. Shen, 1977, Proc. Natl. Acad. Sci. U. S. A., 74, 837, 10.1073/pnas.74.3.837 · DOI · Paper page
  25. Weis, 1975, Biochim. Biophys. Acta, 398, 315, 10.1016/0005-2760(75)90147-2 · DOI
  26. Jeske, 1980, J. Lipid Res., 21, 364, 10.1016/S0022-2275(20)39816-3 · DOI · Paper page
  27. Kovanen, 1979, J. Biol. Chem., 254, 5498, 10.1016/S0021-9258(18)50623-2 · DOI · Paper page
  28. Faust, 1977, J. Biol. Chem., 252, 4861, 10.1016/S0021-9258(17)40133-5 · DOI
  29. Kovanen, 1979, Endocrinology, 104, 599, 10.1210/endo-104-3-599 · DOI
  30. Kovanen, 1979, Endocrinology, 104, 610, 10.1210/endo-104-3-610 · DOI · Paper page
  31. Carr, 1980, Endocrinology, 106, 1854, 10.1210/endo-106-6-1854 · DOI

Cited by

Sorted by citations

Metadata

Authors
Andersen, J. M., & Dietschy, J. M.
Venue
Journal of Biological Chemistry
Publisher
Elsevier BV
Published
1981-07
Volume
256
Issue
14
Pages
7362-7370
ISSN
0021-9258
Cited by
51
References
1
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review