Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

Repeatability of gait data using a functional hip joint centre and a mean helical knee axis

Open access
Besier, Thor F., Sturnieks, Daina L., Alderson, Jacque A., Lloyd, David G. · 2003 · Journal of Biomechanics

Abstract

Repeatability of traditional kinematic and kinetic models is affected by the ability to accurately locate anatomical landmarks (ALs) to define joint centres and anatomical coordinate systems. Numerical methods that define joint centres and axes of rotation independent of ALs may also improve the repeatability of kinematic and kinetic data. The purpose of this paper was to compare the repeatability of gait data obtained from two models, one based on ALs (AL model), and the other incorporating a functional method to define hip joint centres and a mean helical axis to define knee joint flexion/extension axes (FUN model). A foot calibration rig was also developed to define the foot segment independent of ALs. The FUN model produced slightly more repeatable hip and knee joint kinematic and kinetic data than the AL model, with the advantage of not having to accurately locate ALs. Repeatability of the models was similar comparing within-tester sessions to between-tester sessions. The FUN model may also produce more repeatable data than the AL model in subject populations where location of ALs is difficult. The foot calibration rig employed in both the AL and FUN model provided an easy alternative to define the foot segment and obtain repeatable data, without accurately locating ALs on the foot.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0021-9290(03)00087-3

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 23 references

Cited by

See all 532

Metadata

Authors
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G.
Affiliations
The University of Western Australia (AU)
Corresponding author
Lloyd, David G.
Venue
Journal of Biomechanics
Publisher
Elsevier BV
Published
2003-08
Volume
36
Issue
8
Pages
1159-1168
ISSN
0021-9290 (ISSN-L)
OpenAlex
W2087343645
Cited by
532
References
23
Citations by year
2026: 8 · 2025: 21 · 2024: 11 · 2023: 12 · 2022: 23 · 2021: 25 · 2020: 28 · 2019: 37 · 2018: 40 · 2017: 31 · 2016: 37 · 2015: 28 · 2014: 45 · 2013: 46 · 2012: 19
FWCI
7.60
Type
journal article
Language
en
Open access
Licence
  • other-oa
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
Locations
  • Journal of Biomechanics (publishedVersion)
  • PubMed (publishedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion)
  • ResearchSpace (University of Auckland) (submittedVersion, other-oa)
Funders
  • Australian Football League
  • National Health and Medical Research Council
  • National Medical Research Council
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
  • Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
Keywords
anatomical landmarks, joint kinematics, joint kinetics
MeSH terms
Ankle Joint, Computer Simulation, Female, Gait, Hip Joint, Humans, Knee Joint, Male, Models, Biological, Movement, Rotation, Sensitivity and Specificity, Stress, Mechanical, Reproducibility of Results, Range of Motion, Articular, Torque

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. https://app.cochat.ai/papers/10.1016/s0021-9290(03)00087-3
The paper
Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G. (2003). Repeatability of gait data using a functional hip joint centre and a mean helical knee axis. Journal of Biomechanics. https://doi.org/10.1016/s0021-9290(03)00087-3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.