Repeatability of gait data using a functional hip joint centre and a mean helical knee axis
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Repeatability of traditional kinematic and kinetic models is affected by the ability to accurately locate anatomical landmarks (ALs) to define joint centres and anatomical coordinate systems. Numerical methods that define joint centres and axes of rotation independent of ALs may also improve the repeatability of kinematic and kinetic data. The purpose of this paper was to compare the repeatability of gait data obtained from two models, one based on ALs (AL model), and the other incorporating a functional method to define hip joint centres and a mean helical axis to define knee joint flexion/extension axes (FUN model). A foot calibration rig was also developed to define the foot segment independent of ALs. The FUN model produced slightly more repeatable hip and knee joint kinematic and kinetic data than the AL model, with the advantage of not having to accurately locate ALs. Repeatability of the models was similar comparing within-tester sessions to between-tester sessions. The FUN model may also produce more repeatable data than the AL model in subject populations where location of ALs is difficult. The foot calibration rig employed in both the AL and FUN model provided an easy alternative to define the foot segment and obtain repeatable data, without accurately locating ALs on the foot.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Hip and knee joint centres were calculated from functional movement tasks, 14,15 which allowed us to determine joint centres independently of marker placement and thus improved the reliability of the kinematics.”
From Lower-Limb Kinematics of Single-Leg Squat Performance in Young Adults (2014) · cites this paper as [14]
Citations
Cites
Cappozzo, A., Catani, F., Della Croce, U., & Leardini, A. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)91394-t · Cited by 1,677
Repeatability of kinematic, kinetic, and electromyographic data in normal adult gait
Kadaba, M. P., Ramakrishnan, H. K., Wootten, M. E., Gainey, J., Gorton, G., & Cochran, G. V. B. (1989) · Journal of Orthopaedic Research · doi:10.1002/jor.1100070611 · Cited by 1,476
A Fortran package for generalized, cross-validatory spline smoothing and differentiation
Woltring, H. J. (1986) · Advances in Engineering Software (1978) · doi:10.1016/0141-1195(86)90098-7 · Cited by 1,055
ISB recommendations for standardization in the reporting of kinematic data
Wu, G., & Cavanagh, P. R. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00017-c · Cited by 884
Three-dimensional kinematics of the human knee during walking
Lafortune, M. A., Cavanagh, P. R., Sommer, H. J., & Kalenak, A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90254-x · Cited by 694
Rigid body motion calculated from spatial co-ordinates of markers
Spoor, C. W., & Veldpaus, F. E. (1980) · Journal of Biomechanics · doi:10.1016/0021-9290(80)90020-2 · Cited by 579
The Transepicondylar Axis Approximates the Optimal Flexion Axis of the Knee
Churchill, D. L., Incavo, S. J., Johnson, C. C., & Beynnon, B. D. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199811000-00016 · Cited by 497
Validation of a functional method for the estimation of hip joint centre location
Leardini, A., Cappozzo, A., Catani, F., Toksvig-Larsen, S., Petitto, A., Sforza, V., Cassanelli, G., & Giannini, S. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00148-1 · Cited by 415 · cited 2×
“Previous investigations have shown the functional method of locating HJCs to be superior to definitions based on regression equations or models of 'best-fit' (Leardini et al., 1999).”
MethodCappozzo, A. (1984) · Human Movement Science · doi:10.1016/0167-9457(84)90004-6 · Cited by 361
Della Croce, U., Cappozzo, A., & Kerrigan, D. C. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513282 · Cited by 256
Cited by
Items 601–625 of 625
Joint center estimation by single-frame optimization
Frick, E., Rahmatalla, S. F., Wilder, D. G., Grosland, N., Sugiyama, H., & Lim, T. H. (2018) · doi:10.17077/etd.itzm-9z0b
Changes in lower extremity stiffness with triathlon specific training
Lorimer, A. V., Hume, P. A., Keogh, J., & Pearson, S. N. (2018) · Bond University Research Portal (Bond University)
Adamowicz, L. (2019) · ScholarWorks -A service of University of Vermont Libraries (University of Vermont)
Xu, W. (2018) · eSpace (Curtin University)
Beeler, D. (2021) · ScholarSpace (University of Hawaii at Manoa)
Plack, M. M., & Birkmeier, M. (2015) · Pediatric Physical Therapy · doi:10.1097/pep.0000000000000103
Saikko, V. O., Morad, O., & Viitala, R. (2022) · Journal of Tribology · doi:10.1115/1.4056224
Hamill, J. (2024) · Progress in Orthopedic Science · doi:10.47363/pos/2024(10)175
Dynamic Control Strategies Used by ACL-Deficient Copers and Non-Copers during Stair Climbing
Ste-Croix, C. (2008) · UWSpace (University of Waterloo)
Κλινική εκτίμηση της λειτουργικής έσω στροφής ισχίου
Mavropanos, T. (2018) · University of Thessaly Institutional Repository (University of Thessaly) · doi:10.26253/heal.uth.12470
Φωτιάδου, Σ. (2004) · University of Thessaly Institutional Repository (University of Thessaly) · doi:10.26253/heal.uth.2456
Contribution to the validation of functional methods in clinical gait analysis
Gómez, S. Á. (2013) · EIA University Library (EIA University)
Evaluation of the functional hip joint centre method in children with cerebral palsy
Öztürk, O. (2021) · Marmara University Open Access System
Hamstring strain injury prevention in high-performance football players
Silva, M. P. (2026) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Unlocking the vault: Functional kinematic profiling of elite level pole vaulters
Baker, J. (2026) · UWA Profiles and Research Repository (UWA) · doi:10.26182/j1tv-jm86
Specification for the Biomechanical Assessment of Stair Negotiation
Meijin, H., Ye, M. A., Houde, D. A. I., Yueming, G. A. O., ZHENG, Z., Shutao, W. E. I., Dongwei, L. I. U., ZHANG, L., Chenyi, G. U. O., Siling, W. U., et al. (2026) · Rehabilitation Medicine · doi:10.3724/sp.j.1329.2026.09001
Transferability of a previously validated IMU system for lower extremity kinematics
Fain, A., Hindle, B., Andersen, J., Nindl, B. C., Bird, M. B., Wills, J. A., & Doyle, T. L. A. (2022) · Macquarie University
THE POWER FLOW THROUGH THE SWINGING LIMB DURING AN INSTEP KICK IN SOCCER
Smith, N. A., Aderson, J., Sweeney, M., & Elliott, B. C. (2008) · Research Bank (Australian Catholic University)
Metadata
- Authors
- Besier, T. F., Sturnieks, D. L., Alderson, J. A., & Lloyd, D. G.
- Affiliations
- The University of Western Australia (AU)
- Corresponding author
- Lloyd, David G.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2003-08
- Volume
- 36
- Issue
- 8
- Pages
- 1159-1168
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2087343645
- Cited by
- 532
- References
- 23
- Citations by year
- 2026: 8 · 2025: 21 · 2024: 11 · 2023: 12 · 2022: 23 · 2021: 25 · 2020: 28 · 2019: 37 · 2018: 40 · 2017: 31 · 2016: 37 · 2015: 28 · 2014: 45 · 2013: 46 · 2012: 19
- FWCI
- 7.60
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- other-oa
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- UWA Profiles and Research Repository (UWA) (submittedVersion)
- ResearchSpace (University of Auckland) (submittedVersion, other-oa)
- Funders
- Australian Football League
- National Health and Medical Research Council
- National Medical Research Council
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Keywords
- anatomical landmarks, joint kinematics, joint kinetics
- MeSH terms
- Ankle Joint, Computer Simulation, Female, Gait, Hip Joint, Humans, Knee Joint, Male, Models, Biological, Movement, Rotation, Sensitivity and Specificity, Stress, Mechanical, Reproducibility of Results, Range of Motion, Articular, Torque
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.