The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
In vitro fatigue of human tendons
Abstract
The purpose of this study was to determine the fatigue behaviour of human tendons in vitro. The testing was accomplished with the use of specially designed grips and the local measurement of tendon cross-sectional area. Ninety specimens prepared from Extensor digitorum longus (EDL) tendons of the foot were subjected to a cyclic square tension-tension stress waveform at physiological frequencies. The maximum tensile stress was normalised to values corresponding to prescribed levels between 10% and 90% of the calculated ultimate tensile strength (UTS) of 100 MPa. The minimum stress was set at 1% of the UTS. A replication of 10 specimens per stress level allowed the use of statistical models for the distribution of fatigue life. Results followed a linear model, of form S = 101.3 - 14.8 log(N), relating the normalised stress to the median number of cycles to failure, therefore suggesting the absence of an endurance limit. The Weibull distribution was found to describe adequately the probability of failure at each stress level. A model which takes into account in vivo healing was proposed. This model was able to explain the presence of intact tendons throughout the lifetime of an individual.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Previous studies (Schechtman and Bader, 1997; Adeeb et al., 2004; Lipps et al., 2013; Purevsuren et al., 2017) reported a high cyclic loading or stress might decrease the number of cycles to cause fatigue failure of ligament and tendon and result in a faster rupture.”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Schechtman and Bader, 1997
Citations
Cites
Textbook of Medical Physiology
Guyton, A. C., & Hall, J. E. (1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,760
Miner, M. A. (1945) · Journal of Applied Mechanics · doi:10.1115/1.4009458 · Cited by 6,537
Statistical Models and Methods for Lifetime Data.
Francis, B. J., & Lawless, J. F. (1983) · Biometrics · doi:10.2307/2531129 · Cited by 2,774
The Mechanical Properties of Rat Tail Tendon
Rigby, B. J., Hirai, N., Spikes, J. D., & Eyring, H. B. (1959) · The Journal of General Physiology · doi:10.1085/jgp.43.2.265 · Cited by 482
The Statistical Treatment of Fatigue Experiments
Amster, S. J., & Johnson, L. G. (1965) · Technometrics · doi:10.1080/00401706.1965.10490284 · Cited by 432
Woo, S. L., Gomez, M. A., Sites, T. J., Newton, P. O., Orlando, C. A., & Akeson, W. H. (1987) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198769080-00014 · Cited by 388
Butler, D. L., Grood, E. S., Noyes, F. R., Zernicke, R. F., & Brackett, K. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90090-3 · Cited by 386
Why are mammalian tendons so thick?
Ker, R. F., Alexander, R. M., & Bennett, M. B. (1988) · Journal of Zoology · doi:10.1111/j.1469-7998.1988.tb02432.x · Cited by 380
Biomechanical Loading of Achilles Tendon During Normal Locomotion
Komi, P. V., Fukashiro, S., & Järvinen, M. (1992) · Clinics in Sports Medicine · doi:10.1016/s0278-5919(20)30506-8 · Cited by 375
Mechanical properties of various mammalian tendons
Bennett, M. B., Ker, R. F., Imery, N. J., & Alexander, R. M. (1986) · Journal of Zoology · doi:10.1111/j.1469-7998.1986.tb03609.x · Cited by 368
Research works printed but not linked: 1
- Palmgren, 1924, Die Lebensdauer von Kugellagern, Z. Ver. Dt. Ing., 68, 339
Cited by
Sorted by citations
Items 101–200 of 218
Sichting, F., Steinke, H., Wägner, M., Fritsch, S., Hädrich, C., & Hammer, N. (2015) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2015.04.028 · Cited by 21
Cheng, R., Wang, H., Jiang, Z., Dimitriou, D., Cheng, C.-K., & Tsai, T.-Y. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.797389 · Cited by 20
Subramani, A. V., Whitley, P. E., Garimella, H. T., & Kraft, R. H. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2020.1764545 · Cited by 20
Multiscale model of fatigue of collagen gels
Dhume, R. Y., Shih, E. D., & Barocas, V. H. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1075-y · Cited by 19
Gallagher, S., & Heberger, J. R. (2015) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2015.03.005 · Cited by 18
Peloquin, J. M., Santare, M. H., & Elliott, D. M. (2018) · Royal Society Open Science · doi:10.1098/rsos.181166 · Cited by 17
A tissue explant system for assessing tendon overuse injury
Devkota, A. C., & Weinhold, P. S. (2005) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.02.008 · Cited by 17
Firminger, C. R., & Edwards, W. B. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104156 · Cited by 16
Wu, J. Z., Brumfield, A., Miller, G. R., Metheny, R., & Cutlip, R. G. (2004) · PubMed · Cited by 16
A Novel, Open-Source, Low-Cost Bioreactor for Load-Controlled Cyclic Loading of Tendon Explants
Pedaprolu, K., & Szczesny, S. E. (2022) · Journal of Biomechanical Engineering · doi:10.1115/1.4053795 · Cited by 15
Islán, M., Haro, F. B., Pedro, P. S., D’Amato, R., Urquijo, E. L., & Méndez, J. A. J. (2018) · Journal of Medical Systems · doi:10.1007/s10916-018-0908-7 · Cited by 15
Devkota, A. C., & Weinhold, P. S. (2010) · Connective Tissue Research · doi:10.3109/03008200903318261 · Cited by 15
Do Dietary Factors Influence Tendon Metabolism?
Scott, A., & Nordin, C. (2016) · Advances in experimental medicine and biology · doi:10.1007/978-3-319-33943-6_27 · Cited by 14
Tendon cell and tissue culture: Perspectives and recommendations
Szczesny, S. E., & Corr, D. T. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25532 · Cited by 14
Götz, C. W., Handge, U. A., Piątek, M., Fray, M. E., & Altstädt, V. (2009) · Polymer · doi:10.1016/j.polymer.2009.09.051 · Cited by 14
Screen, H. R. C., Byers, S. R., Lynn, A. D., Nguyen, V., Patel, D., & Bryant, S. J. (2010) · Advanced Functional Materials · doi:10.1002/adfm.200901711 · Cited by 14
Houghton, L. A., DAWSON, B. T., & Rubenson, J. (2013) · Journal of Applied Biomechanics · doi:10.1123/jab.29.4.453 · Cited by 14
A non-linear multiaxial fatigue damage model for the cervical intervertebral disc annulus
Motiwale, S., Subramani, A. V., Kraft, R. H., & Zhou, X. A. (2018) · Advances in Mechanical Engineering · doi:10.1177/1687814018779494 · Cited by 13
Rehabilitation After Tendon Injuries
Curwin, S. L. (2005) · Springer eBooks · doi:10.1007/1-84628-050-8_24 · Cited by 13
Tendon micromechanics and research methods in tendinopathy.
Archambault, J. M. (2003) · PubMed · Cited by 13
Rodzak, K. M., Slaughter, P. R., Wolf, D. N., Ice, C. C., Fine, S. J., & Zelik, K. E. (2024) · Wearable Technologies · doi:10.1017/wtc.2024.8 · Cited by 12
Fatigue life of bovine meniscus under longitudinal and transverse tensile loading
Creechley, J. J., Krentz, M. E., & Lujan, T. J. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.12.020 · Cited by 12
Adeeb, S. M., Zec, M. L., Thornton, G. M., Frank, C. B., & Shrive, N. G. (2004) · Journal of Biomechanical Engineering · doi:10.1115/1.1800556 · Cited by 11
Does neuromuscular electrostimulation have the potential to increase intrinsic foot muscle strength?
Ebrecht, F., & Sichting, F. (2018) · The Foot · doi:10.1016/j.foot.2018.01.006 · Cited by 11
A multiscale study of morphological changes in tendons following repeated cyclic loading
Makhzoomi, A. K. A., Kirk, T. B., & Allison, G. T. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110790 · Cited by 11
Fatigue of self-healing hierarchical soft nanomaterials: The case study of the tendon in sportsmen
Bosia, F., Merlino, M., & Pugno, N. M. (2014) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2014.335 · Cited by 10
Griffith, K. M., Hammer, L. C., Iannuzzi, N. P., Takatani, K. C., Hsu, J. E., Cotton, J. D., Gee, A. O., Gardner, R. J., & Lack, W. D. (2022) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2022.05.030 · Cited by 10
Schwab, T., Johnston, C. R., Oxland, T. R., & Thornton, G. M. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.04.014 · Cited by 10
Tendon and ligament biochemistry and pathology
Riley, G. P. (2013) · Oxford University Press eBooks · doi:10.1093/med/9780199533909.003.0001 · Cited by 10
Zimmerman, B., Maas, S. A., Weiss, J. A., & Ateshian, G. A. (2024) · Journal of Biomechanical Engineering · doi:10.1115/1.4066219 · Cited by 9
Zec, M. L., Thistlethwaite, P. A., Frank, C. B., & Shrive, N. G. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000108 · Cited by 9
Bioreactors: enabling technologies for research and manufacturing
Egger, D., Nebel, S., Gensler, M., Kreß, S., Hansmann, J., & Kasper, C. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824459-3.00013-5 · Cited by 9
Ker, R. F. (2008) · Springer eBooks · doi:10.1007/978-0-387-73906-9_5 · Cited by 9
Kawanishi, D. T., Brinker, J., Reeves, R. A., Kay, G. N., GROSS, J. N., PIOGER, G., PETITOT, J. C., Esler, A. L., & Grunkemeier, G. L. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb01175.x · Cited by 9
Characterization of hyperelastic and damage behavior of tendons
López-Campos, J. A., Ferreira, J. P. S., Segade, A., Fernández, J. R., & Jorge, R. N. (2020) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2019.1710742 · Cited by 8
Pelvic floor muscle injury during a difficult labor. Can tissue fatigue damage play a role?
Pouca, M. C. P. V., Parente, M., Jorge, R. N., DeLancey, J. O. L., & Ashton‐Miller, J. A. (2021) · International Urogynecology Journal · doi:10.1007/s00192-021-05012-5 · Cited by 8
Cheng, R., Wang, H., Dimitriou, D., Jiang, Z., Cheng, C., & Tsai, T. (2022) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3590 · Cited by 8
Zhu, P., Brückner, A., Neumeyer, T., Standau, T., Ruckdäschel, H., Altstädt, V., Dong, X., & Wang, D. (2022) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.2c02176 · Cited by 8
Islán, M., Carvajal, J., Pedro, P. S., D’Amato, R., Méndez, J. A. J., & Soriano, E. (2017) · Ninth International Conference on Technological Ecosystems for Enhancing Multiculturality (TEEM'21) · doi:10.1145/3144826.3145408 · Cited by 7
A constitutive relation for the tissue composed of type-I collagen fibers under uniaxial tension
Ji, X. L., Li, H. M., & Li, L. X. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.05.029 · Cited by 7
Response of tibialis anterior tendon to a chronic exposure of stretch-shortening cycles: age effects
Ensey, J. S., Hollander, M. S., Wu, J. Z., Kashon, M. L., Baker, B. B., & Cutlip, R. G. (2009) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-8-12 · Cited by 7
The constitutive relation of self-healing hierarchical fiber bundle materials
Ji, X. L., & Li, L. X. (2018) · Journal of Materials Science · doi:10.1007/s10853-018-2658-9 · Cited by 7
Nail-Ulloa, I., Zabala, M. E., Pool, N., Sesek, R., Thiese, M. S., Sesek, R. F., Schall, M. C., & Gallagher, S. (2025) · Ergonomics · doi:10.1080/00140139.2025.2460695 · Cited by 7
Low cycle fatigue properties of porcine aorta — Pilot study
Polzer, S., & Vitásek, R. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.105725 · Cited by 6
Sadeghi, S., Lin, C.-Y., Bader, D. A., & Cortés, D. H. (2018) · Journal of Engineering and Science in Medical Diagnostics and Therapy · doi:10.1115/1.4041503 · Cited by 6
Self-citationCell Culture Conditions: Cultivation of Stem Cells Under Dynamic Conditions
Clementi, A., Egger, D., Charwat, V., & Kasper, C. (2020) · Springer eBooks · doi:10.1007/978-3-319-08831-0_58 · Cited by 5
Fatigue exhaustion of the mitral valve tissue
Javid, F., Shahmansouri, N., Angeles, J., & Mongrain, R. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1070-3 · Cited by 5
Review of human supraspinatus tendon mechanics. Part I: fatigue damage accumulation and failure
Griffith, K. M., Hammer, L. C., Iannuzzi, N. P., Takatani, K. C., Hsu, J. E., Cotton, J. D., Gee, A. O., Gardner, R. J., & Lack, W. D. (2022) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2022.06.017 · Cited by 5
Time-dependent damage in predictions of fatigue behaviour of normal and healing ligaments
Thornton, G. M., Bailey, S. J., & Schwab, T. (2015) · Mechanics of Time-Dependent Materials · doi:10.1007/s11043-015-9267-7 · Cited by 5
Weibull Analyses of the Fatigue Life of Human Tissues
Gallagher, S. (2012) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181312561246 · Cited by 5
Gerber, J. I., Garimella, H. T., & Kraft, R. H. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/346700 · Cited by 5
Subregions of the Rotator Cuff Muscles Present Distinct Anatomy, Biomechanics, and Function
Cavanaugh, E., Santillan, A. A., Hoshikawa, K., & Giambini, H. (2024) · Sports · doi:10.3390/sports12120349 · Cited by 4
Szarek, P., & Ruberti, J. W. (2026) · Sub-cellular biochemistry/Subcellular biochemistry · doi:10.1007/978-3-032-05273-5_10 · Cited by 4
Zhou, Z., Zhou, H., Xu, D., Hooren, B. V., Yuan, Y., Jie, T., Gao, X., Qu, X., Zhang, Z., Gao, Z., et al. (2026) · PLOS Digital Health · doi:10.1371/journal.pdig.0001537 · Cited by 4
In vitro fatigue of human flexor digitorum tendons
Firminger, C. R., Smith, N. C., Edwards, W. B., & Gallagher, S. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106842 · Cited by 4
Hashemi, S. S., Callejas, A., Siles, A. F., Molina, A. R., Martin-Rodriguez, L., & Rus, G. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.114197 · Cited by 4
Muraoka, T., Muramatsu, T., Kanosue, K., Fukunaga, T., & Kanehisa, H. (2005) · International Journal of Sport and Health Science · doi:10.5432/ijshs.3.304 · Cited by 4
Cell Culture Conditions: Cultivation of Stem Cells Under Dynamic Conditions
Clementi, A., Egger, D., Charwat, V., & Kasper, C. (2018) · Springer eBooks · doi:10.1007/978-3-319-37076-7_58-1 · Cited by 4
Fatigue Testing of Human Flexor Tendons Using a Customized 3D-Printed Clamping System
Scholze, M., Safavi, S., Ramezani, M., Ondruschka, B., & Hammer, N. (2022) · Applied Sciences · doi:10.3390/app12157836 · Cited by 4
Volume Loss and Recovery in Bovine Knee Meniscus Loaded in Circumferential Tension
Peloquin, J. M., Santare, M. H., & Elliott, D. M. (2023) · Journal of Biomechanical Engineering · doi:10.1115/1.4062142 · Cited by 4
Validation of A Fatigue Failure-based Risk Assessment Tool For Distal Upper Extremity MSDs
Gallagher, S., Schall, M. C., Sesek, R. F., & Huangfu, R. (2017) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931213601707 · Cited by 4
Firminger, C. R., Haider, I. T., Bruce, O. L., Wannop, J. W., Stefanyshyn, D. J., & Edwards, W. B. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1975683 · Cited by 3
Horvath, P., Gläser, F., Antipova, V., Klug, C., Lin, A. C., Scholze, M., & Hammer, N. (2024) · Applied Sciences · doi:10.3390/app142411537 · Cited by 3
Bi-Directional Fatigue Life Behavior of Bovine Meniscus
Creechley, J. J. (2016) · Scholar Works (Boise State University) · Cited by 3
Fatigue behaviour of biocomposites
Pegoretti, A., & Dorigato, A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100752-5.00019-6 · Cited by 3
Mechanical Characterisation of Tendons in Vitro
(2000) · Pergamon materials series · doi:10.1016/s1470-1804(00)80010-3 · Cited by 3
Quan, W., Zhou, H., Ma, Y., Xu, D., Gao, Z., Wang, X., Radak, Z. O., & Gu, Y. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1741450 · Cited by 2
Validation of Fatigue Failure Risk Assessment Tools Against Physician-Diagnosed Outcomes
Bandekar, A., Sesek, R. F., Schall, M. C., Huangfu, R., Hani, D. B., & Gallagher, S. (2021) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181321651194 · Cited by 2
Lor, W. S., & Kim, J. (2023) · doi:10.1109/ieem58616.2023.10406589 · Cited by 2
Shear Wave Propagation as a Noninvasive Metric of Loading and Microdamage in Tendon Fascicles
Kotha, S. R., Blank, J. L., Kahr, S. M., Reiter, A. J., Candan, S. Ş., Franck, C., & Thelen, D. G. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.107081 · Cited by 2
Takatani, K. C., & Bruchal, L. C. (2017) · Theoretical Issues in Ergonomics Science · doi:10.1080/1463922x.2017.1284281 · Cited by 2
YAMAMOTO, E., & Kousuke, O. H. T. A. (2009) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.4.539 · Cited by 2
Park, J.-G., Park, S., & 정의승 (2006) · Journal of the Ergonomics Society of Korea · doi:10.5143/jesk.2006.25.1.007 · Cited by 2
Biryukov, S. Y. (2023) · Terapevticheskii arkhiv · doi:10.26442/00403660.2023.12.202533 · Cited by 1
Gallagher, S., & Schall, M. C. (2016) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931213601228 · Cited by 1
Upper extremity load during wheelchair related tasks in subjects with a spinal cord injury
van Drongelen, S. (2005) · VU Research Portal · Cited by 1
Ligaments vs tendons in joint reconstruction: a review of histology and biomechanics
Ge, S. M., Alnaif, N. M., Azzi, A. J., & Zadeh, T. (2019) · Muscles Ligaments and Tendons Journal · doi:10.32098/mltj.02.2018.14 · Cited by 1
In Vitro Tensile Fatigue of Human Flexor Digitorum Profundus and Superficialis Tendons
Smith, N. C. (2019) · Cited by 1
Shoulder Risk Assessment Based on Fatigue Failure Theory
Hani, D. B., Gallagher, S., Sesek, R. F., Huangfu, R., Schall, M. C., & Davis, J. (2019) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181319631395 · Cited by 1
In-vitro tensile testing machine for vibration study of fresh rabbit Achilles tendon
Revel, G. M., Scalise, A., Scalise, L., & Pianosi, A. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.446700 · Cited by 1
Fatigue Analysis of Arteries Using Finite Element Method
Banerjee, R. (2012) · NDSU Repository (North Dakota State University) · Cited by 1
Fatigue Failure of Musculoskeletal Tissues
Gallagher, S., & Barbe, M. F. (2022) · Wiley eBooks · doi:10.1002/9781119640172.ch7 · Cited by 1
The influence of cyclic loading on the extensibility of human hamstring muscle-tendon units in vivo
Dombroski, E. (2005) · Tuwhera (Auckland University of Technology)
Soft Tissues and Their Functional Repair
Bader, D. L. (2000) · Springer eBooks · doi:10.1007/978-4-431-66967-8_18
Self-citationTreino moderado de corrida causa alterações nas propriedades biomecânicas do tendão do calcâneo?
de Oliveira, R. R., Bezerra, M. A., Silveira, P. V. D. C., de Mesquita, G. N., Teixeira, M. F. H. B. I., & de Moraes, S. R. A. (2013) · Revista Brasileira de Ciências do Esporte · doi:10.1590/s0101-32892013000300002
different modes on tendon elasticity in vivo Influences of repetitive muscle contractions with
Kanehisa, H., Kawakami, Y., Fukunaga, T., Dempsey, J. A., Romer, L. M., Haverkamp, H. C., Amann, M., Lovering, A. T., Pegelow, D. F., Peltonen, J. T., et al. (2005)
Self-citationtendon structures in vivo Effects of isometric training on the elasticity of human
Kanehisa, H., Ito, M., Fukunaga, T., Wearing, S. C., SMEATHERS, J. E., Hooper, S., Locke, S., Purdam, C. R., Lacy, J., Waugh, C., et al. (2015)
Development and implementation of a simulated cricket batting innings for testing and training
Houghton, L. A. (2012) · UWA Profiles and Research Repository (University of Western Australia)
Fatigue and Creep Failure in Musculoskeletal Tissues
Taylor, D. M. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.00961-9
The interaction of force and repetition on systemic inflammatory cytokine response in a rat model
Gallagher, S., Barbe, M. F., Massicotte, V. S., & Barr-Gillespie, A. E. (2013) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931213571190
Common Musculoskeletal Disorders
Gallagher, S., & Barbe, M. F. (2022) · Wiley eBooks · doi:10.1002/9781119640172.ch2
Peloquin, J. M., Santare, M. H., & Elliott, D. M. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/292623
Use of Varied Definitions of Repetition with the Distal Upper Extremity Tool (DUET)
Gallagher, S., Schall, M. C., Sesek, R. F., & Huangfu, R. (2018) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1541931218621187
Determinants of the Fatigue Life of Musculoskeletal Tissues
Gallagher, S. (2021) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/1071181321651216
Tendons and Jumping: Anatomy and Pathomechanics of Tendon Injuries
Weisskopf, L., Hesse, T., Sokolowski, M., & Hirschmüller, A. (2021) · Springer eBooks · doi:10.1007/978-3-030-60216-1_3
Fatigue behaviour of biocomposites
Pegoretti, A. (2010) · Elsevier eBooks · doi:10.1533/9781845697372.3.465
Using Fatigue Failure Principles to Assess MSD Risk
Gallagher, S., & Barbe, M. F. (2022) · Wiley eBooks · doi:10.1002/9781119640172.ch13
Implications for MSD Prevention
Gallagher, S., & Barbe, M. F. (2022) · Wiley eBooks · doi:10.1002/9781119640172.ch14
Gallagher, S., & Barbe, M. F. (2022) · Wiley eBooks · doi:10.1002/9781119640172.ch1
Metadata
- Authors
- Schechtman, H., & Bader, D. L.
- Affiliations
- University of London (GB)
- Corresponding author
- Bader, D.L.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1997-08
- Volume
- 30
- Issue
- 8
- Pages
- 829-835
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2065382062
- Cited by
- 218
- References
- 30
- Citations by year
- 2026: 9 · 2025: 6 · 2024: 7 · 2023: 8 · 2022: 19 · 2021: 11 · 2020: 9 · 2019: 8 · 2018: 14 · 2017: 8 · 2016: 9 · 2015: 9 · 2014: 4 · 2013: 10 · 2012: 7
- FWCI
- 3.73
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
- Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- tendon fatigue, human tendon, extensor digitorum longus, cyclic tensile loading, fatigue life distribution, Weibull distribution, fatigue limit, ultimate tensile strength, tendon healing
- MeSH terms
- Aged, Aged, 80 and over, Foot, Humans, Middle Aged, Models, Biological, Tendons, Tensile Strength, Muscle Fatigue, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review