A Novel Application of the Principles of Linear Elastic Fracture Mechanics (LEFM) to the Fatigue Behavior of Tendon Tissue
Abstract
BACKGROUND: Experiments on the fatigue of tendons have shown that cyclic loading induces failure at stresses lower than the ultimate tensile strength (UTS) of the tendons. The number of cycles to failure (Nf) has been shown to be dependent upon the magnitude of the applied cyclic stress. METHOD OF APPROACH: Utilizing data collected by Schechtman (1995), we demonstrate that the principles of Linear Elastic Fracture Mechanics (LEFM) can be used to predict the fatigue behavior of tendons under cyclic loading for maximum stress levels that are higher than 10% of the ultimate tensile strength (UTS) of the tendon (the experimental results at 10% UTS did not fit with our equations). CONCLUSIONS: LEFM and other FM approaches may prove to be very valuable in advancing our understanding of damage accumulation in soft connective tissues.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
High cyclic loading or stress might decrease the number of cycles to cause fatigue failure of ligament and tendon and result in faster rupture.
“Previous studies (Schechtman and Bader, 1997; Adeeb et al., 2004; Lipps et al., 2013; Purevsuren et al., 2017) reported a high cyclic loading or stress might decrease the number of cycles to cause fatigue failure of ligament and tendon and result in a faster rupture.”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Adeeb et al., 2004
Cites
A Critical Analysis of Crack Propagation Laws
Paris, P. C., & Erdoğan, F. (1963) · Journal of Basic Engineering · doi:10.1115/1.3656900 · Cited by 7,168 · see citing works
Elementary engineering fracture mechanics
Broek, D. (1982) · Springer eBooks · doi:10.1007/978-94-009-4333-9 · Cited by 2,895 · see citing works
Fracture mechanics : fundamentals and applications
Anderson, T. (1995) · Cited by 2,004 · see citing works
Mechanical Behavior of Materials: Engineering Methods for Deformation, Fracture, and Fatigue
Dowling, N. E. (1993) · Cited by 1,462 · see citing works
Mechanistic fracture criteria for the failure of human cortical bone
Nalla, R. K., Kinney, J. H., & Ritchie, R. O. (2003) · Nature Materials · doi:10.1038/nmat832 · Cited by 734 · see citing works
Elementary engineering fracture mechanics
Broek, D. (1982) · Springer eBooks · doi:10.1007/978-94-011-9055-8 · Cited by 579 · see citing works
Viscoelastic properties of collagen: synchrotron radiation investigations and structural model
Puxkandl, R., Žižak, I., Paris, O., et al. (2002) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.2001.1033 · Cited by 526 · see citing works
Introduction to Fracture Mechanics
Robert O., R., & Liu, L. (2021) · Elsevier eBooks · doi:10.1016/c2020-0-03038-0 · Cited by 476 · see citing works
In Vitro fatigue of Human Tendons
Schechtman, H., & Bader, D. L. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00033-x · Cited by 218 · see citing works
Experimental validation of a microcracking-based toughening mechanism for cortical bone
Vashishth, D., Tanner, K. E., & Bonfield, W. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00319-6 · Cited by 159 · see citing works
Fatigue Quality of Mammalian Tendons
Ker, R. F., Wang, X. T., & Pike, A. V. L. (2000) · Journal of Experimental Biology · doi:10.1242/jeb.203.8.1317 · Cited by 152 · see citing works
Kahler, B., Swain, M. V., & Moule, A. J. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00327-5 · Cited by 150 · see citing works
Ranking the fracture toughness of thin mammalian soft tissues using the scissors cutting test
Pereira, B. P., Lucas, P. W., & Swee‐Hin, T. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00101-7 · Cited by 139 · see citing works
Biomechanics of integrative cartilage repair
Ahsan, T., & Sah, R. L. (1999) · Osteoarthritis and Cartilage · doi:10.1053/joca.1998.0160 · Cited by 138 · see citing works
Mecholsky, J. J. (1995) · Dental Materials · doi:10.1016/0109-5641(95)80044-1 · Cited by 138 · see citing works
Hannafin, J. A., & ARNOCZKY, S. P. (1994) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100120307 · Cited by 133 · see citing works
Fracture of wood under mixed mode loading
Jernkvist, L. O. (2001) · Engineering Fracture Mechanics · doi:10.1016/s0013-7944(00)00127-2 · Cited by 133 · see citing works
Measurement of the fracture toughness of extensible connective tissues
Purslow, P. P. (1983) · Journal of Materials Science · doi:10.1007/bf00540731 · Cited by 123 · see citing works
Fracture of wood under mixed mode loading
Jernkvist, L. O. (2001) · Engineering Fracture Mechanics · doi:10.1016/s0013-7944(00)00128-4 · Cited by 122 · see citing works
Thornton, G. M., Shrive, N. G., & Frank, C. B. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(02)00028-1 · Cited by 116 · see citing works
Self-citationCriterion for Mixed Mode Fracture in Wood
Mall, S., Murphy, J. F., & Shottafer, J. E. (1983) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1983)109:3(680 · Cited by 113 · see citing works
Fracture of Articular Cartilage
Chin-Purcell, M. V., & Lewis, J. L. (1996) · Journal of Biomechanical Engineering · doi:10.1115/1.2796042 · Cited by 110 · see citing works
Fatigue damage of human tendons
Schechtman, H., & Bader, D. L. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00177-4 · Cited by 107 · see citing works
Positional variations in fracture toughness, stiffness and strength of descending thoracic pig aorta
Purslow, P. P. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90058-1 · Cited by 105 · see citing works
Pollock, R. G., Wang, V. M., Bucchieri, J. S., Cohen, N. P., Huang, C.-Y. C., Pawluk, R. J., Flatow, E. L., Bigliani, L. U., & Mow, V. C. (2000) · Journal of Shoulder and Elbow Surgery · doi:10.1067/mse.2000.108388 · Cited by 88 · see citing works
McCormack, T., & Mansour, J. M. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)00103-6 · Cited by 72 · see citing works
A second study of tensile fatigue properties of human articular cartilage.
Weightman, B., Chappell, D. J., & Jenkins, E. (1978) · Annals of the Rheumatic Diseases · doi:10.1136/ard.37.1.58 · Cited by 71 · see citing works
Shrive, N. G., Chimich, D. D., Marchuk, L. L., Wilson, J., Brant, R., & Frank, C. B. (1995) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100130617 · Cited by 66 · see citing works
Self-citationThe Effects of Hyaluronan on Tissue Healing after Meniscus Injury and Repair in a Rabbit Model
Sonoda, M., Harwood, F. L., Amiel, M. E., Moriya, H., Temple, M. M., Chang, D. G., Lottman, L. M., Sah, R. L., & Amiel, D. (2000) · The American Journal of Sports Medicine · doi:10.1177/03635465000280012801 · Cited by 64 · see citing works
Taylor, D. M., Hazenberg, J. G., & Lee, T. C. (2003) · Journal of Theoretical Biology · doi:10.1016/s0022-5193(03)00222-4 · Cited by 57 · see citing works
Thornton, G. M., Shrive, N. G., & Frank, C. B. (2003) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(03)00051-2 · Cited by 54 · see citing works
Self-citationFracture Mechanics and its Application to Failure in Rubber Articles
Lake, G. J. (2003) · Rubber Chemistry and Technology · doi:10.5254/1.3547761 · Cited by 53 · see citing works
Transmission of Rapidly Applied Loads Through Articular Cartilage Part 2: Cracked Cartilage
Kelly, P., & O'Connor, J. J. (1996) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1996_210_389_02 · Cited by 46 · see citing works
Collagen architecture and failure processes in bovine patellar cartilage
Lewis, J. L., & Johnson, S. L. (2001) · Journal of Anatomy · doi:10.1046/j.1469-7580.2001.19940483.x · Cited by 34 · see citing works
Santis, R. D., Anderson, P., Tanner, K. E., et al. (2000) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1008909830421 · Cited by 30 · see citing works
A model of fracture testing of soft viscoelastic tissues
Koop, B. E., & Lewis, J. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00435-9 · Cited by 23 · see citing works
Dynamic Characterization of Human Tendons
Schechtman, H., & Bader, D. L. (1994) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/pime_proc_1994_208_294_02 · Cited by 22 · see citing works
In vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission
Azangwe, G., Fraser, K., Mathias, K. J., et al. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00039-4 · Cited by 19 · see citing works
Comparison of the durability of cadaveric and autologous fascia using an in vivo model
Kim, H. L., LaBarbera, M., Patel, R. V., et al. (2001) · Urology · doi:10.1016/s0090-4295(01)01315-2 · Cited by 15 · see citing works
Tensile fatigue behaviour of articular cartilage
Bellucci, G., & Seedhom, B. B. (2002) · Biorheology · doi:10.1177/0006355x2002039001002021 · Cited by 13 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Fatigue Injury Risk in Anterior Cruciate Ligament of Target Side Knee during golf Swing
Purevsuren, T., Kwon, M. S., Park, W. M., Kim, K., Jang, S. H., Lim, Y.-T., & Kim, Y. H. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.12.007 · Cited by 28 · see citing works
Cheng, R., Wang, H., Jiang, Z., Dimitriou, D., Cheng, C.-K., & Tsai, T.-Y. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.797389 · Cited by 20 · see citing works
“Previous studies (Schechtman and Bader, 1997; Adeeb et al., 2004; Lipps et al., 2013; Purevsuren et al., 2017) reported a high cyclic loading or stress might decrease the number of cycles to cause fatigue failure of ligament and tendon and result in a faster rupture.”
Background
- Authors
- Adeeb, S. M., Zec, M. L., Thornton, G. M., Frank, C. B., & Shrive, N. G.
- Affiliations
- University of Calgary (CA)
- University of British Columbia (CA)
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2004-10-01
- Volume
- 126
- Issue
- 5
- Pages
- 641-650
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2082064234
- Cited by
- 11
- References
- 40
- Citations by year
- 2024: 1 · 2021: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2012: 1
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Biomechanical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Canadian Institutes of Health Research
- Natural Sciences and Engineering Research Council of Canada
- Topics
- Physical Sciences › Engineering › Mechanics of Materials › Fatigue and fracture mechanics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Tendon Structure and Treatment
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- tendon fatigue, linear elastic fracture mechanics, cyclic loading, number of cycles to failure, ultimate tensile strength
- MeSH terms
- Aged, Aged, 80 and over, Computer Simulation, Elasticity, Hardness, Humans, Middle Aged, Models, Biological, Stress, Mechanical, Tendon Injuries, Tendons, Tensile Strength, Linear Models, In Vitro Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review