The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Large index-fingertip forces are produced by subject-independent patterns of muscle excitation
Open accessAbstract
Are fingertip forces produced by subject-independent patterns of muscle excitation? If so, understanding the mechanical basis underlying these muscle coordination strategies would greatly assist surgeons in evaluating options for restoring grasping. With the finger in neutral ad- abduction and flexed 45 degrees at the MCP and PIP, and 10 degrees at DIP joints, eight subjects attempted to produce maximal voluntary forces in four orthogonal directions perpendicular to the distal phalanx (palmar, dorsal, lateral and medial) and in one direction collinear with it (distal). Forces were directed within 4.7 +/- 2.2 degrees (mean +/- S.D.) of target and their magnitudes clustered into three distinct levels (p < 0.05; post hoc pairwise RMANOVA). Palmar (27.9 +/- 4.1 N), distal (24.3 +/- 8.3 N) and medial (22.9 +/- 7.8 N) forces were highest, lateral (14.7 +/- 4.8 N) was intermediate, and dorsal (7.5 +/- 1.5 N) was lowest. Normalized fine-wire EMGs from all seven muscles revealed distinct muscle excitation groups for palmar, dorsal and distal forces (p < 0.05; post hoc pairwise RMANOVA). Palmar force used flexors, extensors and dorsal interosseous; dorsal force used all muscles; distal force used all muscles except for extensors; medial and lateral forces used all muscles including significant co-excitation of interossei. The excitation strategies predicted to achieve maximal force by a 3-D computer model (four pinjoints, inextensible tendons, extensor mechanism and isometric force models for all seven muscles) reproduced the observed use of extensors and absence of palmar interosseous to produce palmar force (to regulate net joint flexion torques), the absence of extensors for distal force, and the use of intrinsics (strong MCP flexors) for dorsal force. The model could not predict the interossei co-excitation seen for medial and lateral forces, which may be a strategy to prevent MCP joint damage. The model predicts distal force to be most sensitive to dorsal interosseous strength, and palmar and distal forces to be very sensitive to MCP and PIP flexor moment arms, and dorsal force to be sensitive to the moment arm of and the tension allocation to the PIP extensor tendon of the extensor mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. S. (2017) · CRC Press eBooks · doi:10.1201/9781315136370 · Cited by 6,694
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,021
Self-citationA Mathmematical Introduction to Robotic Manipulation
Murray, R. M., Li, Z., & Sastry, S. (1994) · Cited by 2,676
Grip and pinch strength: normative data for adults.
Mathiowetz, V. G., Kashman, N., Volland, G., Weber, K., Dowe-Keval, M., & Rogers, S. R. (1985) · PubMed · Cited by 2,154
Neurobiology of muscle fatigue
Enoka, R. M., & Stuart, D. G. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.5.1631 · Cited by 1,429
Clinical mechanics of the hand
Brand, P. W. (1985) · Medical Entomology and Zoology · Cited by 586
Foundations of robotics: analysis and control
(1991) · Choice Reviews Online · doi:10.5860/choice.28-5104 · Cited by 535
Tendon excursion and moment arm of index finger muscles
An, K. N., Ueba, Y., Chao, E. Y., Cooney, W. P., & Linscheid, R. L. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90074-x · Cited by 385
Lieber, R. L., Jacobson, M. D., Fazeli, B. M., Abrams, R. A., & Botte, M. J. (1992) · The Journal Of Hand Surgery · doi:10.1016/0363-5023(92)90444-t · Cited by 369
Long, C., Conrad, P. W., Hall, E. A., et al. (1970) · PubMed · Cited by 282
Cited by
Optimality principles in sensorimotor control
Todorov, E. (2004) · Nature Neuroscience · doi:10.1038/nn1309 · Cited by 1,746
The Dynamics of Legged Locomotion: Models, Analyses, and Challenges
Holmes, P., Full, R. J., Koditschek, D., & Guckenheimer, J. (2006) · SIAM Review · doi:10.1137/s0036144504445133 · Cited by 714
Muscle Synergies Characterizing Human Postural Responses
Torres-Oviedo, G., & Ting, L. H. (2007) · Journal of Neurophysiology · doi:10.1152/jn.01360.2006 · Cited by 551
Neuromechanics of muscle synergies for posture and movement
Ting, L. H., & McKay, J. L. (2007) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2008.01.002 · Cited by 514
Hand function: peripheral and central constraints on performance
Schieber, M. H., & Santello, M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01063.2003 · Cited by 483
Metadata
- Authors
- Valero-Cuevas, F. J., Zajac, F. E., & Burgar, C. G.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1998-08
- Volume
- 31
- Issue
- 8
- Pages
- 693-703
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2130732995
- Cited by
- 306
- References
- 25
- FWCI
- 3.98
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Large index-fingertip forces are produced by subject-independent patterns of muscle excitation. https://app.cochat.ai/papers/10.1016/s0021-9290(98)00082-7
- The paper
- Valero-Cuevas, F. J., Zajac, F. E., & Burgar, C. G. (1998). Large index-fingertip forces are produced by subject-independent patterns of muscle excitation. Journal of Biomechanics. https://doi.org/10.1016/s0021-9290(98)00082-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.