An improved method for measuring tibiofemoral contact areas in total knee arthroplasty: a comparison of K-scan sensor and Fuji film
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,055
Fukubayashi, T., & Kurosawa, H. (1980) · Acta Orthopaedica Scandinavica · doi:10.3109/17453678008990887 · Cited by 813
A study of lower-limb mechanics during stair-climbing.
Andriacchi, T. P., Andersson, G. B., Fermier, R. W., Stern, D., & Galante, J. O. (1980) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198062050-00008 · Cited by 765
WASIELEWSKI, R. C., GALANTE, J. O., LEIGHTY, R. M., NATARAJAN, R. N., & ROSENBERG, A. G. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00005 · Cited by 563 · cited 1×
“(Collier et al., 1990; Kadoya et al., 1997; Wang et al., 1995; Wasielewski et al., 1994) Many factors contribute to wear and failure of UHMWPE including component geometry and loading conditions.”
BackgroundLoad-bearing mode of the knee joint: physical behavior of the knee joint with or without menisci.
Kurosawa, H., Fukubayashi, T., & Nakajima, H. (1980) · PubMed · Cited by 528
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 499
Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint with or Without Menisci
KUROSAWA, H., FUKUBAYASHI, T., & NAKAJIMA, H. (1980) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198006000-00039 · Cited by 469
Function of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 319
The transmission of load through the human hip joint
Greenwald, A. S., & O'Connor, J. J. (1971) · Journal of Biomechanics · doi:10.1016/0021-9290(71)90041-8 · Cited by 197
In vitro contact stress distribution on the femoral condyles
Brown, T. D., & Shaw, D. T. (1984) · Journal of Orthopaedic Research · doi:10.1002/jor.1100020210 · Cited by 165 · cited 1×
“, 1995); piezoelectric transducers (Brown and Shaw, 1984; Manouel et al., 1992); micro-indentation transducers (Ahmed and Burke, 1983); and computer models (Bartel et al.”
BackgroundAteshian, G. A., Kwak, S. D., Soslowsky, L. J., & Mow, V. C. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90038-8 · Cited by 149 · cited 5×
“Contact area measurements using this jig demonstrated the limitations of Fuji "lms in determining contact areas reported with other studies (Ateshian et al., 1994; Stewart et al., 1995; Szivek et al., 1995).”
BackgroundMethodInfluentialPatellofemoral joint after total knee arthroplasty
Matsuda, S., Ishinishi, T., White, S., & Whiteside, L. A. (1997) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(97)90010-3 · Cited by 118
Wear Particulate Species and Bone Loss in Failed Total Joint Arthroplasties
Kadoya, Y., Revell, P. A., Kobayashi, A., Al-Saffar, N., Scott, G., & Freeman, M. A. R. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199707000-00016 · Cited by 117
Tibiofemoral Contact Pressures in Degenerative Joint Disease
Riegger‐Krugh, C., Gerhart, T. N., Powers, W. R., et al. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199803000-00035 · Cited by 75 · cited 1×
“, 1996) Similar to tibiofemoral contact area and pressures in the intact cadaver knee, these values in the prosthetic knee can be in#uenced by many factors including load magnitude, loading time, joint position, component design and experimental method (Riegger-Krugh et al., 1998).”
BackgroundKirby, R. (1996) · New Zealand Engineering · Cited by 25
Cited by
Tibiofemoral Contact Mechanics after Serial Medial Meniscectomies in the Human Cadaveric Knee
Lee, S. J., Aadalen, K. J., Malaviya, P., Lorenz, E. P., Hayden, J. K., Farr, J., Kang, R. W., & Cole, B. J. (2006) · The American Journal of Sports Medicine · doi:10.1177/0363546506286786 · Cited by 435
Li, G., DeFrate, L. E., Zayontz, S., Park, S. E., & Gill, T. J. (2004) · Journal of Orthopaedic Research · doi:10.1016/j.orthres.2003.11.011 · Cited by 169
Al-Fakih, E., Abu Osman, N. A., & Mahamd Adikan, F. R. (2012) · Sensors · doi:10.3390/s121012890 · Cited by 159
“Measurements of contact area, contact force and stress distribution in the tibiofemoral joint have been made using commercially available stress-sensitive films such as I-Scan and Fujifilm [40–43].”
MethodNagura, T., Matsumoto, H., Kiriyama, Y., Chaudhari, A., & Andriacchi, T. P. (2006) · Journal of Applied Biomechanics · doi:10.1123/jab.22.4.305 · Cited by 91
“The reported contact area of total knee prostheses is between 100 and 850 mm(2), and there were 30 to 50% reductions in the contact area with flexion of 110 degrees or more (Chapman-Sheath et al., 2003; Harris et al., 1999; Stukenborg-Colsman et al., 2002; Nakayama et al., 2005).”
Metadata
- Authors
- Harris, M. L., Morberg, P., Bruce, W. J. M., & Walsh, W. R.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1999-09
- Volume
- 32
- Issue
- 9
- Pages
- 951-958
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2070424218
- Cited by
- 159
- References
- 15
- FWCI
- 3.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.