Abstract
This review will attempt to provide an overview as well as a theoretical and practical understanding of the use of microextraction technologies for drug analysis. The majority of the published reports to date focus on the use of fibre solid-phase microextraction and so the review is significantly focused on this technology. Other areas of microextraction such as single drop and solvent film microextraction are also described. Where there are insufficient examples in the literature to illustrate important concepts, examples of non-drug analyses are presented. The review is intended for readers new to the field of microextraction or its use in drug extraction, but also provides an overview of the most recent advances in the field which may be of interest to more experienced users. Particular emphasis is placed on the effect various sample matrices have on extraction characteristics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, microextraction techniques, for example solid phase microextraction (SPME) and liquid phase microextraction (LPME), which will be discussed below, are considered to be green extraction techniques, owing to the use of very small quantities of solvents of the extraction phase in relation to the volume of the sample or to the solvent volume used in classical approaches [7].”
From Microextraction Techniques with Deep Eutectic Solvents (2020) · cites this paper as [7]
Citations
Cites
Solid phase microextraction with thermal desorption using fused silica optical fibers
Arthur, C. L., & Pawliszyn, J. (1990) · Analytical Chemistry · doi:10.1021/ac00218a019 · Cited by 4,997
Self-citationSolid phase microextraction : theory and practice
Pawliszyn, J. B. (1997) · Medical Entomology and Zoology · Cited by 2,277
Self-citationSolvent Microextraction into a Single Drop
Jeannot, M. A., & Cantwell, F. F. (1996) · Analytical Chemistry · doi:10.1021/ac960042z · Cited by 1,282
Pedersen-Bjergaard, S., & Rasmussen, K. E. (1999) · Analytical Chemistry · doi:10.1021/ac990055n · Cited by 1,245
Buffers for pH and Metal Ion Control
Perrin, D. D., & Dempsey, B. (1979) · Springer eBooks · doi:10.1007/978-94-009-5874-6 · Cited by 987
Applications of Solid Phase Microextraction
(1999) · Royal Society of Chemistry eBooks · doi:10.1039/9781847550149 · Cited by 830
Analytical Chemistry in a Drop. Solvent Extraction in a Microdrop
Liu, H., & Dasgupta, P. K. (1996) · Analytical Chemistry · doi:10.1021/ac960145h · Cited by 751
He, Y., & Lee, H. K. (1997) · Analytical Chemistry · doi:10.1021/ac970242q · Cited by 681
Dynamics of organic compound extraction from water using liquid-coated fused silica fibers
Louch, D., Motlagh, S., & Pawliszyn, J. (1992) · Analytical Chemistry · doi:10.1021/ac00034a020 · Cited by 603
Self-citationCunningham's Text-Book of Anatomy.
(1952) · Annals of Internal Medicine · doi:10.7326/0003-4819-36-1-204_2 · Cited by 574
Research works printed but not linked: 18
- H. Lord, J. Pawliszyn, Evolution of SPME. Invited review, J. Chromatogr. A (in press).
- Ugland, 1999, M. Krogh and K.E. Rasmussen. J, Pharm, Biomed. Anal., 19, 463
- Kroll, 1998, Pharmazie, 53, 172
- Ahnfelt, 1980, Acta Pharm. Suec., 17, 307
- Majors, 1996, LC–GC, 14, 54
- Makino, 1997, Chromatography, 18, 185
- Ishii, 1997, Jpn. J. Forensic Toxicol., 15, 189
- Reubsaet, 1998, J. Pharmaceut. Biomed. Anal., 18, 667, 10.1016/S0731-7085(98)00275-1 · DOI
- Seno, 1997, Jpn. J. Forensic Toxicol., 15, 16
- Kumazawa, 1995, Jpn. J. Forenic Toxicol., 13, 207
- Kumazawa, 1995, Jpn. J. Forensic Toxicol., 13, 182
- Kumazawa, 1995, Jpn. J. Forensic Toxicol., 13, 25
- Okeyo, 1997, J. High Resolut. Chromatogr., 20, 171, 10.1002/jhrc.1240200309 · DOI
- Yashiki, 1995, Jpn. J. Forensic Toxicol., 13, 17
- Lee, 1998, Jpn. J. Forensic. Toxicol., 16, 64
- 1989, Clinical Chemistry, Vol. 106, 219
- Kongshaug, 1999, Chromatographia, 50, 247, 10.1007/BF02490660 · DOI
- Z. Mester, J. Lam, R. Sturgeon, J. Pawliszyn, J. Anal. At. Spectrom. (in press).
Cited by
Items 301–400 of 467
Wu, J., Lu, G., & Huang, X. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105549 · Cited by 14
Aghamohammadi, M., Shahdousti, P., & Harooni, B. (2015) · Microchemical Journal · doi:10.1016/j.microc.2015.07.028 · Cited by 14
Chang, M. S., Shen, J. Y., Yang, S.-H., & Wu, G. J. (2012) · Toxicological & Environmental Chemistry Reviews · doi:10.1080/02772248.2012.684687 · Cited by 16
“Addition of NaCl seemed to be helpful for the recovery of 4- n -NP but gave a negative recovery enhancement to TCS and DBP (Lord and Pawliszyn 2000 ).”
Pan, Y., Chen, F., Zhang, M., Wang, T., Xu, Z., Zhang, W., Chu, Q., & Ye, J. (2013) · Electrophoresis · doi:10.1002/elps.201200320 · Cited by 16
A Microfluidic SPLITT Device for Fractionating Low-Molecular Weight Samples
Kinde, T. F., & Dutta, D. (2013) · Analytical Chemistry · doi:10.1021/ac400843s · Cited by 14
van Hout, M. W. J., Jas, V., Niederländer, H. A. G., de Zeeuw, R. A., & de Jong, G. J. (2003) · Journal of Separation Science · doi:10.1002/jssc.200301567 · Cited by 14
Davarani, S. S. H., Masoomi, L., Banitaba, M. H., Zhad, H. R. L. Z., Sadeghi, O., & Samiei, A. (2012) · Chromatographia · doi:10.1007/s10337-012-2213-9 · Cited by 14
Headspace single-drop microextraction and GC–ECD determination of chlorpyrifos-ethyl in rat liver
Wielgomas, B., & Czarnowski, W. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1831-4 · Cited by 14
Zheng, L., Wu, J., Wang, J., Wu, Y., & Huang, X. (2024) · Separation and Purification Technology · doi:10.1016/j.seppur.2024.128548 · Cited by 13
Zhang, Y., Tang, D., Wu, Y., & Huang, X. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.342967 · Cited by 13
Hu, L., & Chen, D. (2009) · Acta Pharmacologica Sinica · doi:10.1038/aps.2009.148 · Cited by 13
A new strategy to eliminate sample mixing during in-tube solid phase microextraction
Yang, Y., Lord, H. L., & Pawliszyn, J. B. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.10.001 · Cited by 13
Self-citationMelwanki, M. B., & Huang, S. (2006) · Journal of Separation Science · doi:10.1002/jssc.200600050 · Cited by 16
Yeh, M., Lin, S., Leong, M., Huang, S., & Fuh, M. (2011) · Analytical Sciences · doi:10.2116/analsci.27.49 · Cited by 16
Chen, H., Wu, J., Xiong, Q., Li, X., & Huang, X. (2022) · Microchemical Journal · doi:10.1016/j.microc.2023.108575 · Cited by 13
Zou, Y., Zhang, Z., Shao, X., Chen, Y., Wu, X., Yang, L., Zhu, J., & Zhang, D. (2014) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2013.873874 · Cited by 15
“increase further, which directly leads to a decrease of the respond.([30,31]) In addition, [C8MIM][PF6] became more easily dissolved in the aqueous phase at higher salt concentration, and thus decrease the extraction efficiency.”
BackgroundMohamed, A. I., Abdel-Wadood, H. M., & Mousa, H. S. (2016) · New Journal of Chemistry · doi:10.1039/c5nj03719k · Cited by 13
Pang, X., Lewis, A. C., & Shaw, M. (2016) · Journal of Separation Science · doi:10.1002/jssc.201600561 · Cited by 13
“The further addition of NaCl increases the solution viscosity, which may potentially decrease the extraction efficiency [23].”
BackgroundPei, M., & Huang, X. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.08.007 · Cited by 13
Horta, R. P., do Amaral, B., Peralta-Zamora, P., & da Silva, B. J. G. (2018) · Journal of Chromatographic Science · doi:10.1093/chromsci/bmy023 · Cited by 13
Wu, J., Yang, R., Liu, J., & Huang, X. (2021) · Talanta · doi:10.1016/j.talanta.2021.122246 · Cited by 12
Granados-Guzmán, G., Díaz-Hernández, M., Álvarez-Román, R., Cavazos-Rocha, N., & Portillo-Castillo, O. J. (2023) · Reviews in Analytical Chemistry · doi:10.1515/revac-2023-0057 · Cited by 12
Applications of mass spectrometry in cosmetic analysis: An overview
Shang, Y., Meng, X., Liu, J., Song, N., Zheng, H., Han, C., & Ma, Q. (2023) · Journal of Chromatography A · doi:10.1016/j.chroma.2023.464175 · Cited by 11
Bodur, S., Erarpat, S., Günkara, Ö. T., & Bakırdere, S. (2021) · Journal of Pharmacological and Toxicological Methods · doi:10.1016/j.vascn.2021.106949 · Cited by 11
“…and microextraction methods such as solid phase microextraction (SPME) (Beale et al., 2018; Kudlejova, Risticevic, & Vuckovic, 2012; Lord & Pawliszyn, 2000; Risticevic, Lord, Górecki, Arthur, & Pawliszyn, 2010), headspace solid phase microextraction (HS-SPME) (Miekisch, Fuchs, Kamysek,…”
Lord, H. L., & Bojko, B. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-416017-0.00010-3 · Cited by 12
Self-citationSPME/GC‐MS in the Characterisation of Terpenic Resins
Bleton, J., & Tchapla, A. (2009) · doi:10.1002/9780470741917.ch10 · Cited by 12
Liao, Y., Ouyang, X., Lü, M., Peng, J., & Huang, X. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105189 · Cited by 11
Gao, X., Lin, J., Li, T., Zhang, X., Zeng, B., Wang, X., & Zhao, F. (2023) · The Analyst · doi:10.1039/d3an01060k · Cited by 11
Hu, J., Cheng, Q., Zhang, Y., Tian, Y., & Duan, Y. (2020) · Analytical Methods · doi:10.1039/d0ay01153c · Cited by 11
Sehati, N., Dizdaş, T. N., Bolat, S., Pelit, F. O., Rasoulifard, M. H., & Pelit, L. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.112310 · Cited by 10
Chen, H., Luo, S., & Huang, X. (2021) · Journal of Separation Science · doi:10.1002/jssc.202100666 · Cited by 10
Luo, S., Wu, J., & Huang, X. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2022.463743 · Cited by 10
Salami, F. H., & Queiroz, M. E. C. (2013) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826076.2013.836710 · Cited by 10
“Thus, it is reasonable to suppose that there is an initial increase in the amount of extracted analyte upon increasing salt concentration, followed by a reduction as the salt interaction with the analytes in solution predominates.([32]) We also evaluated the different solvents (methanol, mobile phase, water, and buffe…”
MethodAsghari, A., Khanalipoor, F., Barfi, B., & Rajabi, M. (2016) · RSC Advances · doi:10.1039/c6ra18795a · Cited by 10
Michulec, M., & Wardencki, W. (2007) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0235-4 · Cited by 10
Advances in Extraction Techniques for Beer Flavor Compounds
Ferreira, I. M., & Guido, L. F. (2023) · Beverages · doi:10.3390/beverages9030071 · Cited by 9
Zhang, Y., Wang, J., Yu, A., Wu, Y., & Huang, X. (2023) · Microchemical Journal · doi:10.1016/j.microc.2023.109776 · Cited by 9
Green Chemistry for Green Solvent Production and Sustainability Toward Green Economy
Mostafazadeh, A. K., Karimiestahbanati, M., Diop, A., Adjallé, K., Drogui, P., & Tyagi, R. D. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821878-5.00017-9 · Cited by 10
Wu, J., Zheng, L., & Huang, X. (2023) · Talanta · doi:10.1016/j.talanta.2023.125572 · Cited by 9
Ahmad, S., Baker, D., Murnane, D., Spooner, N., & Gerhard, U. (2021) · Bioanalysis · doi:10.4155/bio-2021-0109 · Cited by 9
Pre-concentration of 218 multiclass pesticide in groundwater samples using MSU-1 mesoporous sorbent
Kharbouche, L., Galera, M. M., Galiano, F. J. D., & García, M. D. G. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.108168 · Cited by 9
Liquid–Liquid and Solid-Phase Extraction Techniques
Nickerson, B., & Colón, I. (2011) · Springer eBooks · doi:10.1007/978-1-4419-9631-2_4 · Cited by 11
New developments in integrated sample preparation for bioanalysis
van Hout, M. W. J., Niederländer, H. A. G., de Zeeuw, R. A., & de Jong, G. J. (2003) · Handbook of analytical separations · doi:10.1016/s1567-7192(03)80002-5 · Cited by 15
Gal, C., & Nuţiu, R. (2008) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067310701819002 · Cited by 10
Farajzadeh, M. A., & Assadi, A. (2009) · Journal of Separation Science · doi:10.1002/jssc.200800608 · Cited by 9
Nanomaterials for Sample Preparation
Hussain, C. M., & Mitra, S. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00057-0 · Cited by 9
Shabir, G., Lough, W. J., Arain, S. A., & Shar, G. Q. (2006) · Journal of Liquid Chromatography & Related Technologies · doi:10.1080/10826070600598399 · Cited by 9
“Three primary classes of these compounds are known: antimicrobials, antioxidants, and chelating agents.([1]) Preservatives, some of them naturally occurring, are used in a wide range of applications to maintain overall product quality.”
BackgroundNardi, L. (2003) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)01463-2 · Cited by 9
Wang, Y., Wang, Y., Chen, Y., Zheng, X., Han, J., Jing, X., & Yang, J. (2025) · Analytical Methods · doi:10.1039/d4ay01823k · Cited by 10
Zeng, Y., Peng, M., Zhou, H., & Huang, X. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.137982 · Cited by 9
Zahradníčková, H., & Bouman, E. A. P. (2006) · Journal of Separation Science · doi:10.1002/jssc.200500282 · Cited by 8
Li, W., Wu, J., & Huang, X. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.03.056 · Cited by 8
Wang, M. ‐., Chang, H., & Wang, S. (2013) · Journal of the Chinese Chemical Society · doi:10.1002/jccs.201300326 · Cited by 8
Yang, R., Wu, J., Lu, G., & Huang, X. (2021) · Microchemical Journal · doi:10.1016/j.microc.2021.106833 · Cited by 9
Wei, F., Wang, J., Luo, Q., & Huang, X. (2025) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2025.139111 · Cited by 7
Recent Advances in the Combination of Assisted Extraction Techniques
Moreda–Piñeiro, J., & Moreda‐Piñeiro, A. (2017) · Comprehensive analytical chemistry · doi:10.1016/bs.coac.2016.12.002 · Cited by 7
Yu, Y., Lin, Z., Luo, Y., Liao, Y., & Huang, X. (2023) · Separation and Purification Technology · doi:10.1016/j.seppur.2023.125877 · Cited by 7
Jiang, L., Zhao, X. D., Ye, J., Liu, D., Chen, X., & Bi, K. (2012) · Biomedical Chromatography · doi:10.1002/bmc.2790 · Cited by 7
Sagratini, G., Maggi, F., Bílek, T., Papa, F., & Vittori, S. (2011) · Natural Product Research · doi:10.1080/14786419.2011.585757 · Cited by 7
“The fibre can also be desorbed into a LC eluent using a static or dynamic mode for which several commercial interfaces are available (Lord & Pawliszyn, 2000 ; Saito et al, 2002 ).”
BackgroundSaraji, M., Bidgoli, A. A. H., Ensafi, A. A., Heydari‐Bafrooei, E., & Farajmand, B. (2013) · Analytical Methods · doi:10.1039/c3ay40962g · Cited by 9
Kuo, P.-H., Lin, S., & Fuh, M. (2018) · International Journal of Environmental & Analytical Chemistry · doi:10.1080/03067319.2018.1504935 · Cited by 7
Modification of disused floral foam with polyethylene diamine for the removal of heavy metal ions
Yu, Y., Huang, J., Liao, Y., Lin, Z., & Huang, X. (2023) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2023.08.021 · Cited by 7
Synthesis of molecularly imprinted co-polymers for recognition of ephedrine
Tian, S., Guo, Z., Zhang, X., & Wu, X. (2013) · Analytical Methods · doi:10.1039/c3ay41202d · Cited by 12
Headspace Microextraction: Recent Bioanalytical Applications and Issues
Fiamegos, Y. C., Florou, A. V., & Stalikas, C. D. (2009) · Bioanalysis · doi:10.4155/bio.09.132 · Cited by 7
Zeng, Y., Peng, J., Liu, J., & Huang, X. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.465351 · Cited by 6
Li, X., Wang, Z., & Huang, X. (2022) · Journal of Chromatography A · doi:10.1016/j.chroma.2022.463260 · Cited by 6
Needle-Trap Devices for Environmental Sample Preparation
Saito, Y., Ueta, I., Ogawa, M., & Jinno, K. (2012) · Elsevier eBooks · doi:10.1016/b978-0-12-381373-2.00122-8 · Cited by 6
Botrel, B. M. C., Abreu, D. C. P., Bazzana, M. J. F., Rosa, P. V., & Saczk, A. A. (2019) · Food Analytical Methods · doi:10.1007/s12161-019-01467-x · Cited by 6
Chapter 23 Sampling and sample preparation for clinical and pharmaceutical analysis
Kataoka, H., & Lord, H. L. (2002) · Comprehensive analytical chemistry · doi:10.1016/s0166-526x(02)80060-5 · Cited by 13
Self-citationSeparation and identification methods for metalloproteinase inhibitors
Peng, S. X. (2001) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(01)00316-4 · Cited by 6
Influence of solute-solute interactions on membrane filtration
Neale, P. A. (2009) · ERA · Cited by 6
Microextraction Techniques in LC‐MS Bioanalysis
Rodrigues, M., Fortuna, A., Falcão, A., & Alves, G. (2019) · Sample Preparation in LC‐MS Bioanalysis · doi:10.1002/9781119274315.ch8 · Cited by 5
Headspace-solvent microextraction for identification of volatile components ofMyrtus communisL.
Hashemi, P., Abolghasemi, M. M., Ahmadi, S., & Ghiasvand, A. (2009) · Acta Chromatographica · doi:10.1556/achrom.21.2009.1.12 · Cited by 5
Luo, S., Wu, J., & Huang, X. (2022) · Microchemical Journal · doi:10.1016/j.microc.2022.107996 · Cited by 5
Abdali, S., Daneshfar, A., Ghaedi, M., & Khezeli, T. (2016) · Analytical Methods · doi:10.1039/c6ay01598k · Cited by 5
Samanidou, V., Imamidou, I. P., & Papadoyannis, I. N. (2002) · Journal of Liquid Chromatography & Related Technologies · doi:10.1081/jlc-100108739 · Cited by 5
Wang, J., Jiang, D., & Yan, X. (2005) · Analytica Chimica Acta · doi:10.1016/j.aca.2005.04.078 · Cited by 5
A realistic approach to radiation-induced treatment of micropollutants in wastewater
Genç, A., Ergun, E., Kantoğlu, Ö., İnce, M., & Acar, O. (2023) · Chemical Papers · doi:10.1007/s11696-023-03168-6 · Cited by 4
“Under these conditions, the electrostatic interaction between the anionic forms of KET, DCF, and IBF with salt ions in the neutral solution may have reduced their ability to move into the organic phase (Lord and Pawliszyn 2000).”
Application of negligible and full depletion micro-extraction in environmental sciences
Tolessa, T., & Liu, J. (2015) · Trends in Environmental Analytical Chemistry · doi:10.1016/j.teac.2015.04.002 · Cited by 4
Tomaszewski, W., Гунько, В. М., & Skubiszewska-Zięba, J. (2016) · Journal of Separation Science · doi:10.1002/jssc.201501141 · Cited by 4
Vilela, A. D. O., Faroni, L. R. D., Rodrigues, A. A. Z., Heleno, F. F., de Queiroz, M. E. L. R., Moura, E. D. S., & Gomes, J. L. (2020) · ACS Omega · doi:10.1021/acsomega.0c01385 · Cited by 7
Chronology of preceding medico-legal practices with Reference to post-mortem forensic toxicology
Singh, R. (2022) · Forensic Science International Reports · doi:10.1016/j.fsir.2022.100275 · Cited by 4
Monitoring potential semiochemicals in individual mouse urine samples
Kayali-Sayadi, M. N., Polo-Díez, L. M., & Salazar, I. (2005) · Chemoecology · doi:10.1007/s00049-005-0305-9 · Cited by 4
“Fortunately, to date there are several systems used in conjunction with gas chromatography (GC) to analyse volatiles in urine samples, and the one we have chosen, SPME ( Lord & Pawliszyn 2000 ), is capable of determining low concentrations of volatile and semi-volatile organic compounds.”
MethodSemenistaya, E. N., Virus, E. D., & Rodchenkov, G. M. (2009) · Russian Journal of Physical Chemistry A · doi:10.1134/s0036024409040037 · Cited by 4
PDMS extraction bars for the determination of volatile aromatic hydrocarbons in water and wastewater
da Silva, D. S., Brenner, C. G. B., Mayer, F. M., Montipó, S., & Martins, A. F. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200491 · Cited by 6
Sample Pretreatment in Clinical Chemistry
Papadoyannis, I. N., & Samanidou, V. (2003) · doi:10.1201/9780203911105-3 · Cited by 4
Solid‐Phase Microextraction for Drug Analysis
Lord, H. L. (2010) · doi:10.1002/9780813823621.ch20 · Cited by 4
Self-citationWang, S., Fu, C., Lin, Z., Lin, Y., Xu, Y., Gao, Z., Zhang, F., Fang, L., Li, X., & Fu, J. (2025) · Journal of Molecular Liquids · doi:10.1016/j.molliq.2025.128577 · Cited by 3
Zhang, Y., Huang, Y., Peng, J., & Huang, X. (2023) · Journal of Separation Science · doi:10.1002/jssc.202300250 · Cited by 3
Meng, X., Zhang, Y., Song, X., Luo, Q., & Huang, X. (2024) · Journal of Chromatography A · doi:10.1016/j.chroma.2024.464800 · Cited by 3
Zheng, L., Wang, L., Lü, M., & Huang, X. (2025) · Journal of Chromatography A · doi:10.1016/j.chroma.2025.465860 · Cited by 3
Strating, S. J., Juarez, T. J., Stevens, M. E., White, D. W., & Smith, P. A. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.831982 · Cited by 3
“”(10) The SPME technique is usually employed for passive sampling, where analytes in the system being sampled diffuse into a thin layer of polymer material coated over a small fused silica fiber.”
MethodOnline Automated Micro Sample Preparation for High-Performance Liquid Chromatography
Kataoka, H., Ishizaki, A., & Saito, K. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.89079 · Cited by 4
Luo, S., Song, X., Peng, J., & Huang, X. (2022) · Journal of Separation Science · doi:10.1002/jssc.202200034 · Cited by 3
Sardar, M. R., Yang, Y., & Wei, Y. (2011) · Review Journal of Chemistry · doi:10.1134/s2079978011030022 · Cited by 2
de Oliveira, C. D. R. (2005) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.9.2005.tde-21082007-160740 · Cited by 4
Chapter 1 Gas chromatographic analysis of environmental amines with selective detectors
Kataoka, H., Yamamoto, S., & Narimatsu, S. (2001) · Handbook of analytical separations · doi:10.1016/s1567-7192(01)80004-8 · Cited by 3
Greif, M., Rosin, J., Rößler, T., Knepper, T. P., Hühn, C., Wagner, S., & Pütz, M. (2025) · Forensic Science International · doi:10.1016/j.forsciint.2025.112659 · Cited by 2
Yu, Y., Wei, F., Liu, B. L., Wu, Y., & Huang, X. (2025) · Microchimica Acta · doi:10.1007/s00604-025-07786-7 · Cited by 2
“…analytes obtained with pseudo-second-order model vary from 0.9967 to 0.9977, which are higher that of simulated with pseudo-first-order, Elovich and intra-particle diffusion models, signifying the adsorption procedure mainly relies on chemical interactions formed between TPs and the PFMN [30, 31].”
InfluentialZeng, Y., Wang, J., Luo, S., & Huang, X. (2024) · Microchemical Journal · doi:10.1016/j.microc.2024.110823 · Cited by 2
Metadata
- Authors
- Lord, H., & Pawliszyn, J.
- Affiliations
- University of Waterloo (CA)
- Corresponding author
- Lord, Heather
- ORCID
- Pawliszyn, Janusz
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 2000-11
- Volume
- 902
- Issue
- 1
- Pages
- 17-63
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2068966336
- Cited by
- 468
- References
- 113
- Citations by year
- 2026: 3 · 2025: 11 · 2024: 10 · 2023: 16 · 2022: 14 · 2021: 14 · 2020: 12 · 2019: 12 · 2018: 19 · 2017: 15 · 2016: 18 · 2015: 14 · 2014: 14 · 2013: 22 · 2012: 23
- FWCI
- 1.90
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Life Sciences › Pharmacology, Toxicology and Pharmaceutics › Toxicology › Forensic Toxicology and Drug Analysis
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Keywords
- microextraction, single-drop microextraction, pharmaceutical analysis, sample matrix effects
- MeSH terms
- Adsorption, Body Fluids, Breath Tests, Chemistry, Physical, Chromatography, Liquid, Pharmaceutical Preparations, Hair, Humans, Microchemistry, Illicit Drugs, Technology, Pharmaceutical, Chemical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.