Comparison of slab gel electrophoresis and capillary electrophoresis for the detection of the fluorescently labeled polymerase chain reaction products of short tandem repeat fragments
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
The sizing capability of slab gel electrophoresis for short tandem repeat (STR) fragments was compared to the sizing capability of capillary electrophoresis (CE). Both systems used automated laser fluorescence detection to detect four fluorescent dyes, enabling the use of an internal lane standard within each sample. The STR fragments were amplified using a multiplex polymerase chain reaction (PCR) in which the STR fragments Hum CD-4, Hum TH01, Hum D21S11 and Hum SE33 were amplified simultaneously. The reproducibility of the size calling was determined for both systems. The average standard deviation obtained for the slab gel system was 0.2, which was comparable to the standard deviation of 0.12 obtained for the CE system. The CE system produced results comparable to those obtained on the slab gel system, with a level of precision of +/- 1.0 bp (between instruments).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Currently, STR profiling is predominantly performed by resolving multiplexed, fluorescently labeled polymerase chain reaction (PCR) amplicons using capillary electrophoresis (Deforce et al., 1998).”
From Short tandem repeat profiling via next-generation sequencing for cell line authentication (2023) · cites this paper as Deforce et al., 1998
Citations
Cites
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Chelex 100 as a Medium for Simple Extraction of DNA for PCR-Based Typing from Forensic Material
Walsh, P. S., Metzger, D. A., & Higuchi, R. (2013) · BioTechniques · doi:10.2144/000114018 · Cited by 5,830
Hypervariable ‘minisatellite’ regions in human DNA
Jeffreys, A. J., Wilson, V., & Thein, S. L. (1985) · Nature · doi:10.1038/314067a0 · Cited by 3,741
Genetic variation at five trimeric and tetrameric tandem repeat loci in four human population groups
Edwards, A., Hammond, H. A., Jin, L., Caskey, C. T., & Chakraborty, R. (1992) · Genomics · doi:10.1016/0888-7543(92)90371-x · Cited by 1,426
Evaluation of 13 short tandem repeat loci for use in personal identification applications.
Hammond, H. A., Li, J., Zhong, Y., Caskey, C. T., & Chakraborty, R. (1994) · PubMed · Cited by 431
Automated DNA profiling employing multiplex amplification of short tandem repeat loci.
Kimpton, C. P., Gill, P., Walton, A., Urquhart, A., Millican, E. S., & Adams, M. (1993) · Genome Research · doi:10.1101/gr.3.1.13 · Cited by 394
Frégeau, C. J., & Fourney, R. M. (1993) · PubMed · Cited by 217
Kimpton, C., Fisher, D., Watson, S., Adams, M., Urquhart, A., Lygo, J., & Gill, P. (1994) · International Journal of Legal Medicine · doi:10.1007/bf01224776 · Cited by 183
Clayton, T. M., Whitaker, J. P., & Maguire, C. N. (1995) · Forensic Science International · doi:10.1016/0379-0738(95)01787-9 · Cited by 121
Lins, A. M., Sprecher, C., Puers, C., & Schumm, J. (1996) · BioTechniques · doi:10.2144/96205rr01 · Cited by 70
Research works printed but not linked: 5
- Hammond, 1994, Am. J. Hum. Genet., 55, 175
- Edwards, 1991, Am. J. Hum. Genet., 49, 74G
- Wyman, 1980, Proc. Natl. Acad. Sci. U.S.A., 77, 233
- Frégeau, 1993, BioTechniques, 15, 100
- Walsh, 1991, BioTechniques, 10, 506
Cited by
Jäger, A. C., Alvarez, M. L., Davis, C. P., Guzmán, E., Han, Y., Way, L., Walichiewicz, P., Silva, D., Pham, N., Caves, G., et al. (2017) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2017.01.011 · Cited by 314
Forensic DNA Analysis on Microfluidic Devices: A Review
Horsman, K. M., Bienvenue, J. M., Blasier, K. R., & Landers, J. P. (2007) · Journal of Forensic Sciences · doi:10.1111/j.1556-4029.2007.00468.x · Cited by 180
“Separations that typically required several hours on the slab gels could be completed in approximately 30 min (8).”
BackgroundMass spectrometry-based proteomics as a tool to identify biological matrices in forensic science
Steendam, K. V., Ceuleneer, M. D., Dhaenens, M., Hoofstat, D. E. O. V., & Deforce, D. L. D. (2012) · International Journal of Legal Medicine · doi:10.1007/s00414-012-0747-x · Cited by 140
“Since this procedure is the first step of the chelex DNA extraction, the pellet can be used for DNA analysis [17].”
Self-citationBlair, M. W., Garris, A. J., Iyer‐Pascuzzi, A. S., Chapman, B., Kresovich, S., & McCouch, S. R. (2003) · Theoretical and Applied Genetics · doi:10.1007/s00122-003-1231-2 · Cited by 95
“…the technologies available for high through-put SNP and SSR detection, such as oligo nucleotide-based arrays (Cho et al. 1999) and multiplexed arrays in capillary machines (Deforce et al. 1998), respectively, make rapid screening of large populations very routine using either of these technologies.”
BackgroundPresence and potential of cell free DNA in different types of forensic samples
Vandewoestyne, M., Hoofstat, D. E. O. V., Franssen, A. J. P. M., Nieuwerburgh, F. V., & Deforce, D. L. D. (2013) · Forensic Science International Genetics · doi:10.1016/j.fsigen.2012.12.005 · Cited by 96
Self-citation
Metadata
- Authors
- Deforce, D. L. D., Millecamps, R. E. M., Van Hoofstat, D., & Van den Eeckhout, E. G.
- Affiliations
- Ghent University (BE)
- ORCID
- Deforce, Dieter L.D
- Venue
- Journal of Chromatography A
- Publisher
- Elsevier BV
- Published
- 1998-05
- Volume
- 806
- Issue
- 1
- Pages
- 149-155
- ISSN
- 0021-9673 (ISSN-L)
- OpenAlex
- W2130810468
- Cited by
- 33
- References
- 18
- Citations by year
- 2023: 1 · 2021: 1 · 2018: 1 · 2017: 1 · 2016: 2 · 2015: 1 · 2013: 2 · 2012: 2
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Chromatography A (publishedVersion)
- PubMed (publishedVersion)
- Ghent University Academic Bibliography (Ghent University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Forensic and Genetic Research
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Genetic diversity and population structure
- Keywords
- microsatellite markers, capillary electrophoresis, slab gel electrophoresis, DNA fragment sizing, multiplex PCR, forensic DNA profiling, D21S11, TH01, CD4, SE33
- MeSH terms
- DNA, Electrophoresis, Fluorescent Dyes, Humans, Repetitive Sequences, Nucleic Acid, Sensitivity and Specificity, Polymerase Chain Reaction, Electrophoresis, Capillary
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of slab gel electrophoresis and capillary electrophoresis for the detection of the fluorescently labeled polymerase chain reaction products of short tandem repeat fragments. https://app.cochat.ai/papers/10.1016/s0021-9673(97)00394-4
- The paper
- Deforce, D. L. D., Millecamps, R. E. M., Van Hoofstat, D., & Van den Eeckhout, E. G. (1998). Comparison of slab gel electrophoresis and capillary electrophoresis for the detection of the fluorescently labeled polymerase chain reaction products of short tandem repeat fragments. Journal of Chromatography A. https://doi.org/10.1016/s0021-9673(97)00394-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.