Chronopotentiometry for the advanced current–voltage characterisation of bipolar membranes
The DOI matches its Crossref record.
Abstract
Compared to steady-state current?voltage curves, chronopotentiometric measurements allow us to distinguish the contributions to the overall electric potential difference across a bipolar membrane. In this paper, the characteristic values of the electric potential difference across the bipolar membrane at different times are correlated to the corresponding concentration profiles in the bipolar membrane layers and the ion-transport processes are identified. For over-limiting current densities (i.e. current densities above the limiting current density), it is possible to distinguish the reversible and irreversible contributions to the steady-state electric potential difference. The irreversible contribution is attributed to the energy required to overcome the electric resistance whereas the reversible contribution corresponds to the electrochemical potential due to concentration gradients in the membrane layers. Further, the ohmic resistance of the membrane in equilibrium with the surrounding solution has been compared to the resistance in the transport state. For low current densities, the equilibrium resistance is lower than the transport resistance stemming from internal concentration polarisation. In contrast, the large numbers of hydroxide ions and protons produced at high current densities result in a reduced ohmic transport resistance due to their high ionic mobility. This reduced resistance is not enough to stop the increase of the irreversible contribution with higher current densities. With the possibility to split the steady-state potential into its contributions, bipolar membrane chronopotentiometry is a useful tool to identify transport limitations and to improve bipolar membranes for a reduced overall electric potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bipolar membranes: A review on principles, latest developments, and applications
Pärnamäe, R., Mareev, S., Nikonenko, V., Melnikov, S., Sheldeshov, N., Zabolotskii, V., Hamelers, H. V. M., & Tedesco, M. (2021) · Journal of Membrane Science · doi:10.1016/j.memsci.2020.118538 · Cited by 610
Current status of ion exchange membranes for power generation from salinity gradients
DLUGOLECKI, P., NYMEIJER, K., METZ, S., & WESSLING, M. (2008) · Journal of Membrane Science · doi:10.1016/j.memsci.2008.03.037 · Cited by 537
Self-citationTransport limitations in ion exchange membranes at low salt concentrations
Długołęcki, P., Anet, B., Metz, S. J., Nijmeijer, K., & Wessling, M. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2009.09.033 · Cited by 342
Self-citationAn innovative beneficial reuse of seawater concentrate using bipolar membrane electrodialysis
Yang, Y., Gao, X., Fan, A., Fu, L., & Gao, C. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2013.07.066 · Cited by 156
Process design for lithium recovery using bipolar membrane electrodialysis system
Hwang, C. W., Jeong, M. H., Kim, Y. J., Son, W. K., Kang, K. S., Lee, C. S., & Hwang, T. S. (2016) · Separation and Purification Technology · doi:10.1016/j.seppur.2016.03.013 · Cited by 85
Metadata
- Authors
- Wilhelm, F. G., van der Vegt, N. F. A., Wessling, M., & Strathmann, H.
- Venue
- Journal of Electroanalytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2001-04
- Volume
- 502
- Issue
- 1-2
- Pages
- 152-166
- ISSN
- 1572-6657 (ISSN-L)
- OpenAlex
- W1966943932
- Cited by
- 88
- References
- 0
- FWCI
- 2.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Chronopotentiometry for the advanced current–voltage characterisation of bipolar membranes. https://app.cochat.ai/papers/10.1016/s0022-0728(01)00348-5
- The paper
- Wilhelm, F. G., van der Vegt, N. F. A., Wessling, M., & Strathmann, H. (2001). Chronopotentiometry for the advanced current–voltage characterisation of bipolar membranes. Journal of Electroanalytical Chemistry. https://doi.org/10.1016/s0022-0728(01)00348-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.