CoChat

Chronopotentiometry for the advanced current–voltage characterisation of bipolar membranes

Wilhelm, F.G., van der Vegt, N.F.A., Wessling, M., Strathmann, H. · 2001 · Journal of Electroanalytical Chemistry
Cited by 88

The DOI matches its Crossref record.

Abstract

Compared to steady-state current?voltage curves, chronopotentiometric measurements allow us to distinguish the contributions to the overall electric potential difference across a bipolar membrane. In this paper, the characteristic values of the electric potential difference across the bipolar membrane at different times are correlated to the corresponding concentration profiles in the bipolar membrane layers and the ion-transport processes are identified. For over-limiting current densities (i.e. current densities above the limiting current density), it is possible to distinguish the reversible and irreversible contributions to the steady-state electric potential difference. The irreversible contribution is attributed to the energy required to overcome the electric resistance whereas the reversible contribution corresponds to the electrochemical potential due to concentration gradients in the membrane layers. Further, the ohmic resistance of the membrane in equilibrium with the surrounding solution has been compared to the resistance in the transport state. For low current densities, the equilibrium resistance is lower than the transport resistance stemming from internal concentration polarisation. In contrast, the large numbers of hydroxide ions and protons produced at high current densities result in a reduced ohmic transport resistance due to their high ionic mobility. This reduced resistance is not enough to stop the increase of the irreversible contribution with higher current densities. With the possibility to split the steady-state potential into its contributions, bipolar membrane chronopotentiometry is a useful tool to identify transport limitations and to improve bipolar membranes for a reduced overall electric potential.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-0728(01)00348-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 88

Metadata

Authors
Wilhelm, F. G., van der Vegt, N. F. A., Wessling, M., & Strathmann, H.
Venue
Journal of Electroanalytical Chemistry
Publisher
Elsevier BV
Published
2001-04
Volume
502
Issue
1-2
Pages
152-166
ISSN
1572-6657 (ISSN-L)
OpenAlex
W1966943932
Cited by
88
References
0
FWCI
2.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Chronopotentiometry for the advanced current–voltage characterisation of bipolar membranes. https://app.cochat.ai/papers/10.1016/s0022-0728(01)00348-5
The paper
Wilhelm, F. G., van der Vegt, N. F. A., Wessling, M., & Strathmann, H. (2001). Chronopotentiometry for the advanced current–voltage characterisation of bipolar membranes. Journal of Electroanalytical Chemistry. https://doi.org/10.1016/s0022-0728(01)00348-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.