Measurement of apolipoprotein A-I concentration in nonhuman primate serum by enzyme-linked immunosorbent assay (ELISA).
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A sensitive and specific enzyme-linked immunosorbent assay (ELISA) for nonhuman primate serum apolipoprotein A-I (apoA-I) is described. The assay is a noncompetitive, sandwich ELISA in which polystyrene microtiter plates were used with purified, monospecific goat anti-monkey apoA-I antibodies adsorbed on the wells. The serum samples were added to the coated wells, incubated, and after washing, antibodies conjugated to horseradish peroxidase were added. After further washing, the bound label was assayed. A heat treatment step, 52 degrees C for 3 hr, was used to maximize the apoA-I immunoreactive sites in diluted serum. Serum samples extracted with chloroform-methanol, delipidated with tetramethylurea, or denatured by heating gave essentially equivalent results. The working range of the apoA-I standards was 0.5 to 5 ng and parallel responses were observed for apoA-I in serum, in isolated HDL, and in buffer as a purified apoprotein. Recovery of apoA-I added to serum was quantitative (106 +/- 3%). The intra- and interassay coefficients of variation were 6.2 and 6.9%, respectively. The enzyme immunoassay yielded values that compared favorably with those obtained by radial immunodiffusion (r = 0.84). ApoA-I concentration in African green monkey serum was highly correlated with the HDL cholesterol concentration (r = 0.86). It is concluded that this ELISA is an accurate and precise method for determination of apoA-I concentrations in primate serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High density lipoprotein as a protective factor against coronary heart disease
Gordon, T., Castelli, W. P., Hjortland, M. C., Kannel, W. B., & Dawber, T. R. (1977) · The American Journal of Medicine · doi:10.1016/0002-9343(77)90874-9 · Cited by 5,059
Cited by
Inhibition of miR-33a/b in non-human primates raises plasma HDL and lowers VLDL triglycerides
Rayner, K. J., Esau, C. C., Hussain, F. N., McDaniel, A. L., Marshall, S. M., van Gils, J. M., Ray, T. D., Sheedy, F. J., Goedeke, L., Liu, X., et al. (2011) · Nature · doi:10.1038/nature10486 · Cited by 706
Adams, M. R., Kaplan, J. R., Manuck, S. B., Koritnik, D. R., Parks, J. S., Wolfe, M. S., & Clarkson, T. B. (1990) · Arteriosclerosis: An Official Journal of the American Heart Association, Inc. · doi:10.1161/01.atv.10.6.1051 · Cited by 605
Self-citationAnthony, M. S., Clarkson, T. B., Hughes, C. L., Morgan, T. M., & Burke, G. L. (1996) · The Journal of Nutrition · doi:10.1093/jn/126.1.43 · Cited by 534
Timmins, J. M., Lee, J.-Y., Boudyguina, E., Kluckman, K. D., Brunham, L. R., Mulya, A., Gebre, A. K., Coutinho, J. M., Colvin, P. L., Smith, T. L., et al. (2005) · Journal of Clinical Investigation · doi:10.1172/jci23915 · Cited by 447
Adams, M. R., Register, T. C., Golden, D. L., Wagner, J. D., & Williams, J. K. (1997) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.17.1.217 · Cited by 374
Metadata
- Authors
- Koritnik, D. L., & Rudel, L. L.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 1983-12
- Volume
- 24
- Issue
- 12
- Pages
- 1639-1645
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W1779067738
- Cited by
- 95
- References
- 1
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.