CoChat

Measurements of adipose tissue respiration in a closed chamber using an oxygen sensor: methodological considerations

Open access
Hallgren, P, Korsback, S, Sjöström, L · 1990 · Journal of Lipid Research

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

Abstract

A new polarographic system for measurement of oxygen consumption in vitro has been constructed to minimize different types of errors. The system was built of polyamide-6, Monax glass, stainless steel, and rubber to diminish oxygen leakage and gas capacitance properties. With these materials the system was gas-tight. Nevertheless, the incubation chambers had oxygen capacitance properties that had to be corrected for mathematically. Thus, in order to obtain more exact absolute values of the respiratory rate, the apparent respiratory slopes were continuously corrected for delta pO2. Furthermore, the initial slope observed in the absence of biological material was also taken into account. Using these variables, the apparent slope (mm Hg/min) could be adjusted by subtracting the following correction factor: correction factor = 0.00306 X delta pO2 + 0.198 X (initial slope). This correction gave a high degree of linearity and an overall error on the order of 10%. Without the described correction for the oxygen capacitance, the true respiratory rate may be underestimated by up to 50%.

Overview

Integrity signals

Registry

Crossref · 10.1016/s0022-2275(20)38778-2

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. Burky, 1977, Respiration chambers for measuring oxygen consumption of small aquatic molluscs with Clarktype polarographic electrodes, Malacol. Rev., 10, 71

Cited by

See all 14

Metadata

Authors
Hallgren, P., Korsback, S., & Sjöström, L.
Affiliations
Sahlgrenska University Hospital (SE)
Venue
Journal of Lipid Research
Publisher
Elsevier BV
Published
1990-04
Volume
27
Issue
9
Pages
996-1005
ISSN
0022-2275 (ISSN-L)
OpenAlex
W2466538390
Cited by
14
References
34
Citations by year
2021: 1 · 2018: 1 · 2013: 2
FWCI
0.27
Type
journal article
Language
en
Open access
Licence
Locations
  • Journal of Lipid Research (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Adipose Tissue and Metabolism
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biochemistry › Lipid metabolism and biosynthesis
  • Physical Sciences › Chemistry › Electrochemistry › Electrochemical Analysis and Applications
Keywords
oxygen consumption, polarographic oxygen sensor, closed chamber, respiratory rate measurement, oxygen leakage, measurement error
MeSH terms
Adipose Tissue, Animals, Humans, Methods, Oxygen Consumption, Perfusion, Polarography, Rats, In Vitro Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurements of adipose tissue respiration in a closed chamber using an oxygen sensor: methodological considerations. https://app.cochat.ai/papers/10.1016/s0022-2275(20)38778-2
The paper
Hallgren, P., Korsback, S., & Sjöström, L. (1990). Measurements of adipose tissue respiration in a closed chamber using an oxygen sensor: methodological considerations. Journal of Lipid Research. https://doi.org/10.1016/s0022-2275(20)38778-2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.