Quantification of cholesterol in all lipoprotein classes by the VAP-II method.
Open accessThe DOI matches its Crossref record.
Abstract
We have developed a high resolution microvolume Vertical Auto Profile (VAP) method for the simultaneous measurement of cholesterol in all lipoprotein classes, including lipoprotein[a] (Lp[a]) and intermediate density lipoprotein (IDL). This method, designated as VAP-II, uses a non-segmented continuous flow (controlled-dispersion flow) analyzer for the enzymatic analysis of cholesterol in lipoprotein classes separated by a short spin (47 min) single vertical ultracentrifugation. Cholesterol concentrations of high (HDL), low (LDL), very low (VLDL), and intermediate (IDL) density lipoproteins, as well as Lp[a], are determined by decomposing the spectrophotometric absorbance curve, obtained from the continuous analysis of the centrifuged sample, into its components using software developed in this laboratory. Analysis by VAP-II is rapid and sensitive (as little as 40 microliters plasma is required per assay). The resolution of lipoprotein peaks is considerably enhanced in the present analyzer compared to the previous analyzer (VAP-I, which used the Technicon AutoAnalyzer); improvement is especially noticeable for Lp[a] and IDL. Total and lipoprotein cholesterol values obtained by VAP-II correlated well with the values obtained by Northwest Lipid Research Laboratories (NWLRL). VAP-II Lp[a] cholesterol values also correlated well with the Lp[a] mass values obtained by an immunoassay technique performed at NWLRL (r = 0.907). The reproducibility and accuracy of the method are within the requirements of the CDC-NHLBI (Centers for Disease Control-National Heart, Lung, and Blood Institute) Lipid Standardization Program.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Effects of the amount and intensity of exercise on plasma lipoproteins
Kraus, W. E., Houmard, J. A., Duscha, B. D., Knetzger, K. J., Wharton, M. B., McCartney, J. S., Bales, C. W., Henes, S., Samsa, G. P., Otvos, J. D., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020194 · Cited by 1,554
Self-citationAtherogenic Lipoprotein Particles in Atherosclerosis
Carmena, R., Duriez, P., & Fruchart, J.-C. (2004) · Circulation · doi:10.1161/01.cir.0000131511.50734.44 · Cited by 494
Beyond Low-Density Lipoprotein Cholesterol
Arsenault, B. J., Rana, J. S., Stroes, E. S. G., Després, J.-P., Shah, P. K., Kastelein, J. J. P., Wareham, N. J., Boekholdt, S. M., & Khaw, K.-T. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.07.057 · Cited by 342
Low-Density Lipoprotein Size and Cardiovascular Disease: A Reappraisal
Sacks, F. M., & Campos, H. (2003) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2003-030636 · Cited by 241
Yeang (2015) · doi:10.1097/mol.0000000000000171 · Cited by 152
Metadata
- Authors
- Kulkarni, K. R., Garber, D. W., Marcovina, S. M., & Segrest, J. P.
- Venue
- Journal of Lipid Research
- Publisher
- Elsevier BV
- Published
- 1994-01
- Volume
- 35
- Issue
- 1
- Pages
- 159-168
- ISSN
- 0022-2275 (ISSN-L)
- OpenAlex
- W2136647159
- Cited by
- 136
- References
- 0
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantification of cholesterol in all lipoprotein classes by the VAP-II method. https://app.cochat.ai/papers/10.1016/s0022-2275(20)40123-3
- The paper
- Kulkarni, K. R., Garber, D. W., Marcovina, S. M., & Segrest, J. P. (1994). Quantification of cholesterol in all lipoprotein classes by the VAP-II method. Journal of Lipid Research. https://doi.org/10.1016/s0022-2275(20)40123-3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.