CoChat

Safety and Efficacy Outcome of Mentor Alpha-1 Inflatable Penile Prosthesis Implantation for Impotence Treatment

Goldstein, Irwin, Newman, Laura, Baum, Neil, Brooks, Marvin, Chaikin, Lewis, Goldberg, Kenneth, McBride, Albert, Krane, Robert J. · 1997 · Journal of Urology
Cited by 155

The DOI matches its Crossref record.

Abstract

PURPOSE: We investigated safety and efficacy outcome pertaining to the Mentor Alpha-1, 3-piece inflatable penile prosthesis for impotence treatment. MATERIALS AND METHODS: A 2-phase, multi-institutional, large scale retrospective study, with independently analyzed medical record (phase I) and questionnaire (phase II) data from consecutive eligible patients of 7 physician investigators was performed from March to October 1993. RESULTS: In phase I there were no morbidities of any type in 394 of the 434 patients (90.8%) (mean age 61 years, range 24 to 88) who underwent Alpha-1 implantation (mean followup 22.2 months, range 0.67 to 44.5). The risk of prosthesis malfunction (fluid leak and auto-inflation) was 2.5%. No cylinder aneurysms were reported. A total of 93.1% of Alpha-1 devices was free from explantation (4.4%) or revision surgery (2.5%) for approximately 2 years from the original implant date. Kaplan-Meier actuarial analyses revealed that cumulative survival of the Alpha-1 prostheses at 12, 24 and 36 months was 98 +/- 1%, 93 +/- 2% and 85 +/- 7% until device malfunction, and 91 +/- 2% 83 +/- 4% and 75 +/- 7% until surgical intervention (revision or explantation). In phase II 89% of the men claimed fulfilled expectations with the Alpha-1 prosthesis as impotence treatment. Satisfaction responses 80% or greater were noted with regard to intercourse ability and confidence, and device rigidity and function. Implantation did not result in greater than 80% satisfaction in partner relationships or feelings (as judged by the patient), social or work confidence, or intercourse frequency. Factors adversely affecting satisfaction included partner feelings of dissatisfaction (as judged by the patient), specific physician investigators and need for explantation/revision surgery. CONCLUSIONS: In 1 of the largest multi-institutional implant outcome studies thus far performed, safety and efficacy data concerning the Alpha-1 contemporary inflatable device were found markedly improved over earlier inflatable prostheses and now compare favorably with historical data from noninflatable rod type devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(01)65058-4

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 155

Metadata

Authors
Goldstein, I., Newman, L., Baum, N., Brooks, M., Chaikin, L., Goldberg, K., McBride, A., & Krane, R. J.
Venue
Journal of Urology
Published
1997-03
Volume
157
Issue
3
Pages
833-839
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W1997827188
Cited by
155
References
0
FWCI
5.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety and Efficacy Outcome of Mentor Alpha-1 Inflatable Penile Prosthesis Implantation for Impotence Treatment. https://app.cochat.ai/papers/10.1016/s0022-5347(01)65058-4
The paper
Goldstein, I., Newman, L., Baum, N., Brooks, M., Chaikin, L., Goldberg, K., McBride, A., & Krane, R. J. (1997). Safety and Efficacy Outcome of Mentor Alpha-1 Inflatable Penile Prosthesis Implantation for Impotence Treatment. Journal of Urology. https://doi.org/10.1016/s0022-5347(01)65058-4

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.