CoChat

ANALYSIS OF BLADDER RELATED NERVE CUFF ELECTRODE RECORDINGS FROM PREGANGLIONIC PELVIC NERVE AND SACRAL ROOTS IN PIGS

JEZERNIK, SAŠO, WEN, JIAN GUO, RIJKHOFF, NICO J.M., DJURHUUS, JENS C., SINKJæR, THOMAS · 2000 · Journal of Urology
Cited by 73

The DOI matches its Crossref record.

Abstract

PURPOSE: Electrical stimulation of appropriate lower urinary tract (LUT) nerves may be used in bladder dysfunction to achieve continence and abolish hyper-reflexic detrusor contractions. It can also be used for consequent emptying of the bladder. To control the time course of the described functional phases, knowledge of bladder sensory information is needed. We investigated if the latter could be extracted from the LUT nerve activity. MATERIALS AND METHODS: In acute experiments using 10 pigs, tripolar cuff electrodes were placed unilaterally around the pelvic nerve and the S3 and S2 roots. The cuff electrode signals, filling rate and the bladder and rectal pressures were recorded during slow and fast bladder fillings/emptyings. RESULTS: Two pigs were excluded from the analysis because of no observed changes in the nerve signals in one animal, and because of electrical noise problems in the other animal. Fast bladder pressure increases resulted in a sudden pelvic nerve signal rise in 6 out of 7 pigs (3 out of 6 for the S3 nerve signal). Slow bladder pressure increase was reflected in the recorded nerve activity only in 3 out of 8 and in 3 out of 7 pigs for the pelvic and S3 cuff signals respectively. In 2 animals small spontaneous bladder contractions were clearly reflected in the pelvic nerve signal (contractions were observed only in 3 pigs). Except in one pig, there were no slow/fast bladder filling responses recorded in the S2 roots. It is shown that the recorded responses were afferent. CONCLUSIONS: Cuff electrodes can be used to record bladder afferent information from the pelvic nerve and the sacral root S3 in pig. Pelvic nerve recordings were more selective than the sacral root recordings. Nerve activity increases were more distinct and repeatable during rapid bladder pressure changes and small spontaneous bladder contractions than during slow bladder fillings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0022-5347(05)67769-5

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 73

Metadata

Authors
JEZERNIK, S., WEN, J. G., RIJKHOFF, N. J. M., DJURHUUS, J. C., & SINKJæR, T.
Venue
Journal of Urology
Published
2000-04
Volume
163
Issue
4
Pages
1309-1314
ISSN
  • 0022-5347 (ISSN-L)
  • 1527-3792
OpenAlex
W2088471626
Cited by
73
References
0
FWCI
4.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ANALYSIS OF BLADDER RELATED NERVE CUFF ELECTRODE RECORDINGS FROM PREGANGLIONIC PELVIC NERVE AND SACRAL ROOTS IN PIGS. https://app.cochat.ai/papers/10.1016/s0022-5347(05)67769-5
The paper
JEZERNIK, S., WEN, J. G., RIJKHOFF, N. J. M., DJURHUUS, J. C., & SINKJæR, T. (2000). ANALYSIS OF BLADDER RELATED NERVE CUFF ELECTRODE RECORDINGS FROM PREGANGLIONIC PELVIC NERVE AND SACRAL ROOTS IN PIGS. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)67769-5

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.