The DOI matches its Crossref record.
IMAGING GUIDED BIOPSY OF RENAL MASSES: INDICATIONS, ACCURACY AND IMPACT ON CLINICAL MANAGEMENT
Abstract
PURPOSE: We evaluated the indications, accuracy and impact of image guided biopsy of focal renal masses. MATERIALS AND METHODS: We retrospectively reviewed 79 image guided renal biopsies in 73 patients. Indications, imaging, and histological and clinical features were analyzed. We assumed that nephrectomy, partial nephrectomy or surgical biopsy of suspicious masses would be done when no percutaneous biopsy had been performed. A change in management was defined as surgical to nonsurgical. RESULTS: Clinical management was altered due to results in 32 of the 79 biopsies (41%) in cases managed nonoperatively, including positive and negative biopsies in those followed clinically and with imaging. Of 79 biopsies 49 (62%) were diagnosed positive for malignancy, including 15 (31%) that were not and 34 (69%) that were renal cell carcinoma. The histological diagnosis was negative on 25 biopsies (32%) and positive or negative on 74 (94%). All 5 of the 79 false-negative biopsies (6%) were due to insufficient tissue and involved highly suspicious imaging findings that required further evaluation, such as repeat biopsy or surgery. Renal cell carcinoma was identified in 4 of the 5 cases. In 12 of the 24 patients (50%) with a pre-biopsy history of nonrenal cancer biopsies were diagnostic of nonrenal cancer. No patient had major complications and in 4 small hematomas were treated with observation only. CONCLUSIONS: Image guided renal mass biopsy is safe, reliable and accurate, and it changes clinical management in many cases by avoiding nephrectomy or other surgical options. Radiologists should promote imaging guided biopsy as a potentially useful option for managing suspicious or indeterminate renal masses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Systematic Review and Meta-analysis of Diagnostic Accuracy of Percutaneous Renal Tumour Biopsy
Marconi, L., Dabestani, S., Lam, T. B., Hofmann, F., Stewart, F., Norrie, J., Bex, A., Bensalah, K., Canfield, S. E., Hora, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.07.072 · Cited by 601
Renal Masses in the Adult Patient: The Role of Percutaneous Biopsy
Silverman, S. G., Gan, Y. U., Mortele, K. J., Tuncali, K., & Cibas, E. S. (2006) · Radiology · doi:10.1148/radiol.2401050061 · Cited by 315
NEUZILLET, Y., LECHEVALLIER, E., ANDRE, M., DANIEL, L., & COULANGE, C. (2004) · Journal of Urology · doi:10.1097/01.ju.0000120147.51090.2b · Cited by 308
Image-guided adrenal and renal biopsy
Sharma, K. V., Venkatesan, A. M., Swerdlow, D., DaSilva, D., Beck, A., Jain, N., & Wood, B. J. (2010) · Techniques in vascular and interventional radiology · doi:10.1053/j.tvir.2010.02.005 · Cited by 68
Self-citation
Metadata
- Authors
- WOOD, B. J., KHAN, M. A., McGOVERN, F., HARISINGHANI, M., HAHN, P. F., & MUELLER, P. R.
- Venue
- Journal of Urology
- Published
- 1999-05
- Volume
- 161
- Issue
- 5
- Pages
- 1470-1474
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2039598434
- Cited by
- 205
- References
- 0
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: IMAGING GUIDED BIOPSY OF RENAL MASSES: INDICATIONS, ACCURACY AND IMPACT ON CLINICAL MANAGEMENT. https://app.cochat.ai/papers/10.1016/s0022-5347(05)68929-x
- The paper
- WOOD, B. J., KHAN, M. A., McGOVERN, F., HARISINGHANI, M., HAHN, P. F., & MUELLER, P. R. (1999). IMAGING GUIDED BIOPSY OF RENAL MASSES: INDICATIONS, ACCURACY AND IMPACT ON CLINICAL MANAGEMENT. Journal of Urology. https://doi.org/10.1016/s0022-5347(05)68929-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.