The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Accuracy and Clinical Role of Fine Needle Percutaneous Biopsy With Computerized Tomography Guidance of Small (Less Than 4.0 Cm) Renal Masses
Abstract
PURPOSE: We evaluated the accuracy and clinical role of fine needle percutaneous biopsy of solid renal masses 4.0 cm or smaller with helical computerized tomography (CT) guidance. MATERIALS AND METHODS: In 88 consecutive patients (mean age 61 years) 88 biopsies were performed. Median tumor size was 2.8 cm. Tumor biopsy was performed with an 18 gauge needle using helical CT guidance in an outpatient setting. At least 2 whole cores per tumor were obtained. RESULTS: Biopsy material was insufficient for analysis in 3 (3.4%) procedures. Median tumor size of failed biopsies was 3.0 cm. There were 5 (5.6%) biopsies which revealed fibrosis and were considered inconclusive. A benign lesion was found in 14 (15.9%) biopsies. In the 66 biopsies positive for malignancy there were 65 cases of renal cell carcinoma and 1 lymphoma. A total of 62 patients underwent surgery. Biopsy changed tumor management in 42 (47.8%) patients who avoided radical nephrectomy, 13 of whom had a lesion which did not require surgery, 1 with a lymphoma and 28 who were treated with partial nephrectomy. Biopsy accuracy for histopathological tumor type and Fuhrman nuclear grade was 92% and 69.8%, respectively. No substantial morbidity occurred. CONCLUSIONS: Fine needle biopsy of small renal masses could select benign lesions for which observation might be an alternative to surgery. The accuracy of fine needle biopsy in identifying histological tumor type was high. However, biopsy was less accurate in evaluating Furhman grade. Biopsy with helical CT guidance could be a key point in tailored management of small solid renal masses and provide important information to those patients harboring renal masses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
HAFEZ, K. S., FERGANY, A. F., & NOVICK, A. C. (1999) · Journal of Urology · doi:10.1016/s0022-5347(05)68071-8 · Cited by 598
Amin, M. B., Corless, C. L., Renshaw, A. A., Tickoo, S. K., Kubus, J., & Schultz, D. S. (1997) · The American Journal of Surgical Pathology · doi:10.1097/00000478-199706000-00001 · Cited by 335
IMAGING GUIDED BIOPSY OF RENAL MASSES: INDICATIONS, ACCURACY AND IMPACT ON CLINICAL MANAGEMENT
WOOD, B. J., KHAN, M. A., McGOVERN, F., HARISINGHANI, M., HAHN, P. F., & MUELLER, P. R. (1999) · Journal of Urology · doi:10.1016/s0022-5347(05)68929-x · Cited by 205
Cited by
EAU Guidelines on Renal Cell Carcinoma: 2014 Update
Ljungberg, B., Bensalah, K., Canfield, S., Dabestani, S., Hofmann, F., Hora, M., Kuczyk, M. A., Lam, T., Marconi, L., Merseburger, A. S., et al. (2015) · European Urology · doi:10.1016/j.eururo.2015.01.005 · Cited by 3,394
Systematic Review and Meta-analysis of Diagnostic Accuracy of Percutaneous Renal Tumour Biopsy
Marconi, L., Dabestani, S., Lam, T. B., Hofmann, F., Stewart, F., Norrie, J., Bex, A., Bensalah, K., Canfield, S. E., Hora, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.07.072 · Cited by 601
Rini, B. I., Campbell, S. C., & Rathmell, W. K. (2006) · Current Opinion in Oncology · doi:10.1097/01.cco.0000219260.60714.c4 · Cited by 379
Patel, H. D., Johnson, M. H., Pierorazio, P. M., Sozio, S. M., Sharma, R., Iyoha, E., Bass, E. B., & Allaf, M. E. (2016) · Journal of Urology · doi:10.1016/j.juro.2015.11.029 · Cited by 364
Renal Masses in the Adult Patient: The Role of Percutaneous Biopsy
Silverman, S. G., Gan, Y. U., Mortele, K. J., Tuncali, K., & Cibas, E. S. (2006) · Radiology · doi:10.1148/radiol.2401050061 · Cited by 315
Metadata
- Authors
- NEUZILLET, Y., LECHEVALLIER, E., ANDRE, M., DANIEL, L., & COULANGE, C.
- Venue
- Journal of Urology
- Published
- 2004-05
- Volume
- 171
- Issue
- 5
- Pages
- 1802-1805
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2020012641
- Cited by
- 308
- References
- 3
- FWCI
- 13.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy and Clinical Role of Fine Needle Percutaneous Biopsy With Computerized Tomography Guidance of Small (Less Than 4.0 Cm) Renal Masses. https://app.cochat.ai/papers/10.1097/01.ju.0000120147.51090.2b
- The paper
- NEUZILLET, Y., LECHEVALLIER, E., ANDRE, M., DANIEL, L., & COULANGE, C. (2004). Accuracy and Clinical Role of Fine Needle Percutaneous Biopsy With Computerized Tomography Guidance of Small (Less Than 4.0 Cm) Renal Masses. Journal of Urology. https://doi.org/10.1097/01.ju.0000120147.51090.2b
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.