CoChat

Five-Year Experience With Temporary Pacemaker Therapy in the Coronary Care Unit

Open access
Hynes, John K., Harrison, Carlos E., Holmes, David R. · 1983 · Mayo Clinic Proceedings
Cited by 97

The DOI matches its Crossref record.

Abstract

The clinical course of 1,022 consecutive patients who received a temporary transvenous pacemaker in the coronary care unit during a 5-year period between January 1976 and January 1981 was reviewed. The route of pacemaker insertion was identified in 942 patients (92.2%) and included antecubital vein cutdown in 606 patients (59.3%), subclavian venipuncture in 177 patients (17.3%), right internal jugular venipuncture in 111 patients (10.9%), and femoral venipuncture in 48 patients (4.7%). Pacemaker-related complications occurred in 140 instances (13.7% morbidity), without associated mortality. The most common complication was the development of a new pericardial rub (54 patients, 5.3%). The right internal jugular approach was associated with the lowest complication rate. On the basis of these findings, it is our practice to insert temporary pacemakers via the right internal jugular or subclavian route.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/s0025-6196(25)18727-2

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 21

  1. Furman, 1958, The use of an intracardiac pacemaker in the correction of total heart block, Surg Forum, 9, 245
  2. Escher, 1970, Emergency treatment of cardiac arrhythmias: emphasis on use of electrical pacing, IAMA, 214, 2028, 10.1001/jama.1970.03180110038008 · doi:10.1001/jama.1970.03180110038008
  3. Fisher, 1977, Cardiac pacing and pacemakers. II. Serial electro-physiologic-pharmacologic testing for control of recurrent tachyarrhythmias, Am Heart J, 93, 658, 10.1016/S0002-8703(77)80018-5 · DOI · Paper page
  4. Waldo, 1976, Continuous rapid atrial pacing to control recurrent or sustained supraventricular tachycardias following open heart surgery, Circulation, 54, 245, 10.1161/01.CIR.54.2.245 · doi:10.1161/01.cir.54.2.245
  5. Resnekov, 1978, Pacemaking and acute myocardial infarction, Impulse, 11, 1
  6. Escher, 1961, Cardiovascular dynamic responses to artificial pacing of patients in heart block (P) (abstract), Circulation, 24, 928
  7. Jernigan, 1970, Use of the internal jugular vein for placement of central venous catheter, Surg Gynecol Obstet, 130, 520
  8. Civetta, 1972, Internal-jugular-vein puncture with a margin of safety, Anesthesiology, 36, 622, 10.1097/00000542-197206000-00019 · doi:10.1097/00000542-197206000-00019
  9. Linos, 1980, Subclavian vein: a golden route, Mayo Clin Proc, 55, 315, 10.1016/S0025-6196(25)38255-8 · doi:10.1016/s0025-6196(25)38255-8
  10. Davidson, 1963, Subclavian venepuncture, Lancet, 2, 1139, 10.1016/S0140-6736(63)90791-8 · doi:10.1016/s0140-6736(63)90791-8
  11. Cheng, 1971, Percutaneous transfemoral venous cardiac pacing: a simple and practical method, Chest, 60, 73, 10.1378/chest.60.1.73 · doi:10.1378/chest.60.1.73
  12. Solomon, 1963, A rapid method for insertion of the pacemaker catheter electrode, Am Heart J, 66, 717, 10.1016/0002-8703(63)90330-2 · DOI
  13. Weinstein, 1973, Temporary transvenous pacing via the percutaneous femoral vein approach: a prospective study of 100 cases, Am Heart J, 85, 695, 10.1016/0002-8703(73)90178-6 · DOI
  14. Webre, 1973, Use of cephalic and basilic veins for introduction of central venous catheters, Anesthesiology, 38, 389, 10.1097/00000542-197304000-00015 · doi:10.1097/00000542-197304000-00015
  15. Lumia, 1973, Temporary transvenous pacemaker therapy: an analysis of complications, Chest, 64, 604, 10.1378/chest.64.5.604 · doi:10.1378/chest.64.5.604
  16. Austin, 1982, Analysis of pacemaker malfunction and complications of temporary pacing in the coronary care unit, Am J Cardiol, 49, 301, 10.1016/0002-9149(82)90505-7 · DOI
  17. Tancredi, 1967, Temporary transvenous catheter-electrode pacing of the heart, Circulation, 36, 598, 10.1161/01.CIR.36.4.598 · doi:10.1161/01.cir.36.4.598
  18. Chastre, 1982, Thrombosis as a complication of pulmonary-artery catheterization via the internal jugular vein: prospective evaluation by phlebography, N Engl J Med, 306, 278, 10.1056/NEJM198202043060506 · doi:10.1056/nejm198202043060506
  19. Nolewajka, 1980, Temporary transvenous pacing and femoral vein thrombosis, Circulation, 62, 646, 10.1161/01.CIR.62.3.646 · DOI · Paper page
  20. Pandian, 1980, Transfemoral temporary pacing and deep vein thrombosis, Am Heart J, 100, 847, 10.1016/0002-8703(80)90065-4 · DOI
  21. Kakkar, 1974, Detection of deep vein thrombosis: survey and current status, Prog Cardiovasc Dis, 17, 207, 10.1016/0033-0620(74)90045-0 · doi:10.1016/0033-0620(74)90045-0

Cited by

Metadata

Authors
Hynes, J. K., Harrison, C. E., & Holmes, D. R.
Venue
Mayo Clinic Proceedings
Publisher
Elsevier BV
Published
1983-02
Volume
58
Issue
2
Pages
122-126
ISSN
0025-6196 (ISSN-L)
OpenAlex
W202912481
Cited by
97
References
0
FWCI
2.29
Type
journal article
Language
en
Open access
hybrid
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.