Prediction and early detection of preterm labor
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Studies of cervical sonography, fetal fibronectin, and uterine contraction monitoring during pregnancy have improved our understanding of how preterm labor occurs, but their use in practice remains uncertain. This article reviews the use of these tests to improve the accuracy of diagnosis of preterm labor and to estimate the likelihood of preterm birth in women with historical risk factors. Because the clinical criteria for a diagnosis of preterm labor are inaccurate until labor is well established, over-diagnosis is common. A cervical length measurement of more than 30 mm or a negative fibronectin obtained from a patient with possible preterm labor can avoid over-diagnosis and unnecessary treatment. There is no role for routine use of either cervical sonography or fibronectin to screen pregnant women for preterm birth risk, but women thought to be at increased risk may be reassured by negative test results. Uterine contraction monitoring has low sensitivity for detecting women at risk of preterm birth. Current use of cervical length and fetal fibronectin in pregnancy is limited to situations where a negative result can avoid unnecessary interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The length of the cervix and the risk of spontaneous premature delivery
Iams, J. D., Goldenberg, R. L., Meis, P. J., Mercer, B. M., Moawad, A., Das, A., Thom, E., McNellis, D., Copper, R. L., Johnson, F., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199602293340904 · Cited by 1,894
Self-citation[The length of the cervix and the risk of spontaneous premature delivery].
Blondel, B. (1996) · PubMed · Cited by 1,378
Obstetrics: Normal and Problem Pregnancies
(2017) · Elsevier eBooks · doi:10.1016/c2013-0-00408-2 · Cited by 1,176
Goldenberg, R. L., Iams, J. D., Mercer, B. M., Meis, P. J., Moawad, A. H., Copper, R. L., Das, A., Thom, E., Johnson, F., McNellis, D., et al. (1998) · American Journal of Public Health · doi:10.2105/ajph.88.2.233 · Cited by 446 · cited 3×
“This scenario is particularly associated with preterm births before 30–32 weeks, is more often followed by long-term morbidity for the infant, and is more likely to recur in subsequent pregnancies.(8) Fibronectin, an extracellular matrix protein, acts as the “glue” that attaches the fetal membranes to the underlying u…”
Self-citationFetal fibronectin as a predictor of preterm birth in patients with symptoms: A multicenter trial
Peaceman, A. M., Andrews, W. W., Thorp, J. M., Cliver, S. P., Lukes, A., Iams, J. D., Coultrip, L., Eriksen, N., Holbrook, R. H., Elliott, J., et al. (1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70431-9 · Cited by 380 · cited 2×
“A positive fibronectin test (50 ng/mL or more) in a patient with symptoms suggestive of preterm labor has been associated with an increase in the likelihood of birth before 34 weeks and birth within 7–14 days of the test.(27,28) However, the positive predictive value for delivery within a week was just 18% in data com…”
Self-citationThe preterm prediction study: Risk factors in twin gestations
Goldenberg, R. L., Iams, J. D., Miodovnik, M., Van Dorsten, J. P., Thurnau, G., Bottoms, S., Mercer, B. M., Meis, P. J., Moawad, A. H., Das, A., et al. (1996) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(96)80051-2 · Cited by 347 · cited 1×
“Fibronectin was less predictive of preterm birth in twins than in singletons when studied at 24–28 weeks in asymptomatic women.(46) 2) When a test result can be used to help determine the appropriate timing for antenatal corticosteroids or to avoid treatment entirely.”
Self-citationBeta‐mimetics in preterm labour: an overview of the randomized controlled trials
KING, J. F., GRANT, A., KEIRSE, M. J. N. C., & CHALMERS, I. (1988) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1988.tb06860.x · Cited by 330
The preterm prediction study: fetal fibronectin testing and spontaneous preterm birth
GOLDENBERG, R., MERCER, B., MEIS, P., COPPER, R., DAS, A., & MCNELLIS, D. (1996) · Obstetrics & Gynecology · doi:10.1016/0029-7844(96)00035-x · Cited by 281
Gomez, R., Galasso, M., Romero, R., Mazor, M., Sorokin, Y., Gonçalves, L., & Treadwell, M. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(94)90014-0 · Cited by 278
Is oncofetal fibronectin a trophoblast glue for human implantation?
Feinberg, R. F., Kliman, H. J., & Lockwood, C. J. (1991) · PubMed · Cited by 260
Cited by
Hendler, I., Goldenberg, R. L., Mercer, B. M., Iams, J. D., Meis, P. J., Moawad, A. H., MacPherson, C. A., Caritis, S. N., Miodovnik, M., Menard, K. M., et al. (2005) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.09.021 · Cited by 327
Self-citationEpidemiology of preterm birth and neonatal outcome
Wen, S. W., Smith, G., Yang, Q., & Walker, M. (2004) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2004.04.002 · Cited by 308
Fele-Žorž, G., Kavšek, G., Novak-Antolič, Ž., & Jager, F. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0350-y · Cited by 255
Prediction and Prevention of Recurrent Spontaneous Preterm Birth
Spong, C. Y. (2007) · Obstetrics & Gynecology · doi:10.1097/01.aog.0000275287.08520.4a · Cited by 236
Deshpande, S., van Asselt, A., Tomini, F., Armstrong, N., Allen, A., Noake, C., Khan, K., Severens, J., Kleijnen, J., & Westwood, M. (2013) · Health Technology Assessment · doi:10.3310/hta17400 · Cited by 235
Physiology and electrical activity of uterine contractions
Garfield, R. E., & Maner, W. L. (2007) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2007.05.004 · Cited by 232
“Furthermore, the measurement of the cervical length is made unreliable by varying amounts of urine in the bladder ([ 30 ], especially see p. 407).”
InfluentialBiochemical predictors of preterm labor: fetal fibronectin and salivary estriol
Ramsey, P. S., & Andrews, W. W. (2003) · Clinics in Perinatology · doi:10.1016/s0095-5108(03)00109-x · Cited by 44
Sprague, A. E., O’Brien, B., Newburn-Cook, C., Heaman, M., & Nimrod, C. (2008) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)32800-6 · Cited by 24
Metadata
- Authors
- Iams, J.
- Venue
- Obstetrics & Gynecology
- Published
- 2003-02
- Volume
- 101
- Issue
- 2
- Pages
- 402-412
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1981713568
- Cited by
- 241
- References
- 42
- FWCI
- 10.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.