Continuous glucose monitoring for the evaluation of gravid women with type 1 diabetes mellitus
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare the daily glycemic profile reflected by continuous and intermittent blood glucose monitoring in pregnant women with type 1 diabetes and to compare the treatment protocols based on the two monitoring methods. METHODS: The study sample consisted of 34 gravid patients at gestational weeks 16-32, with type 1 diabetes being treated by multiple insulin injections. Data derived from the continuous glucose monitoring system for 72 hours were compared with finger stick glucose measurements performed 6-8 times per day. During the study period, patients documented the time of food intake, insulin injections, and hypoglycemic events. Data on demographics, gravidity, parity, body mass index, hemoglobin A1c, and fructosamine levels were collected for each patient. RESULTS: An average (+/- standard deviation) of 780 +/- 54 glucose measurements was recorded for each patient with continuous glucose monitoring. The mean total time of hyperglycemia (glucose level greater than 140 mg/dL) undetected by the finger stick method was 192 +/- 28 minutes per day. Nocturnal hypoglycemic events (glucose level less than 50 mg/dL) were recorded in 26 patients; in all cases, there was an interval of 1-4 hours before clinical manifestations appeared or the event was revealed by random blood glucose examination. Based on the additional information obtained by continuous monitoring, the insulin therapeutic regimen was adjusted in 24 patients (70%). CONCLUSION: Continuous glucose monitoring can diagnose high postprandial blood glucose levels and nocturnal hypoglycemic events that are unrecognized by intermittent blood glucose monitoring and may serve as a basis for determining treatment regimens. A large, prospective study on maternal and neonatal outcome is needed to evaluate the clinical implications of this new monitoring technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abnormal patterns of insulin secretion in non-insulin-dependent diabetes mellitus.
Polonsky, K. S., Given, B. D., Hirsch, L. J., Tillil, H., Shapiro, E. T., Beebe, C., Frank, B. H., Galloway, J. A., & Van Cauter, E. (1988) · New England Journal of Medicine · doi:10.1056/nejm198805123181903 · Cited by 567
Maternal postprandial glucose levels and infant birth weight: the diabetes in early pregnancy study
Jovanovic-Peterson, L., Peterson, C. M., Reed, G. F., Metzger, B. E., Mills, J. L., Knopp, R. H., & Aarons, J. H. (1991) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(91)90637-7 · Cited by 411
A Pilot Study of the Continuous Glucose Monitoring System
Kaufman, F. R., Gibson, L. C., Halvorson, M., Carpenter, S., Fisher, L. K., & Pitukcheewanont, P. (2001) · Diabetes Care · doi:10.2337/diacare.24.12.2030 · Cited by 224
ROSENN, B., MIODOVNIK, M., HOLCBERG, G., KHOURY, J., & SIDDIQI, T. (1995) · Obstetrics & Gynecology · doi:10.1016/0029-7844(94)00415-a · Cited by 161
Cited by
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Murphy, H. R., Rayman, G., Lewis, K., Kelly, S., Johal, B., Duffield, K., Fowler, D., Campbell, P. J., & Temple, R. C. (2008) · BMJ · doi:10.1136/bmj.a1680 · Cited by 358
“Despite promising pilot evaluations of continuous glucose monitoring”
BackgroundContinuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Patterns of Glycemia in Normal Pregnancy
Hernandez, T. L., Friedman, J. E., Van Pelt, R. E., & Barbour, L. A. (2011) · Diabetes Care · doi:10.2337/dc11-0241 · Cited by 170
“Current CGMS technology measures glucose concentrations in interstitial fluid, which are highly correlated with glucometer-derived plasma-corrected glucose measures (34,35).”
BackgroundMethodDiurnal glycemic profile in obese and normal weight nondiabetic pregnant women
Yogev, Y., Ben-Haroush, A., Chen, R., Rosenn, B., Hod, M., & Langer, O. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.06.059 · Cited by 168
Self-citation
Metadata
- Authors
- Yogev, Y.
- Venue
- Obstetrics & Gynecology
- Published
- 2003-04
- Volume
- 101
- Issue
- 4
- Pages
- 633-638
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W1981849304
- Cited by
- 77
- References
- 4
- FWCI
- 4.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous glucose monitoring for the evaluation of gravid women with type 1 diabetes mellitus. https://app.cochat.ai/papers/10.1016/s0029-7844(02)02714-x
- The paper
- Yogev, Y. (2003). Continuous glucose monitoring for the evaluation of gravid women with type 1 diabetes mellitus. Obstetrics & Gynecology. https://doi.org/10.1016/s0029-7844(02)02714-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.